Page 249 of 648
51 &52 Delco Remy 3 474 220
59 Melco E 002 B90 131
131 & 132 EA Thomson 20 165 653
136 General Motors 16 038 177
137 Melco E 001 190 272
141 (EA) Thomson 20 165 865 - B - LA 11 - LD6
IL1 AEI
0 2 + 2,5 mdaN
114
I Champion L82
0 Ml4 x I,25 > 0,8 --t 0,9 mm
c Eyquem 755 X 0
/J lllljm~ 7 Bougicord 403 1 : 500 mm 2300 Q 3 : 825mm4150Q
+ 10 + mm o&!-lrt lo%-, 2 : 700 mm 3450 Q 4 : 900 mm 4550 Q
Page 250 of 648
MA 210.00/4 2
L
t------l c-
IC IC IC
I I
;2 t2
l-n I RI, /
I
77
81 VG MG i;iN VN fi I
11
AEI
lB 6 1 lBl3l ml lB 7 1 lB2 1 IN
1 T'B iB -
Zl 22 22
Ll
-
Turbo
L---- -------.
'ml
136
8531
Page 251 of 648
1 rnA 210.00/4a
#
@Eia
137
~ 2
I 141 136
51 &52 : Delco Remy 3 474 220
131 & 132 : EA (Thomson) 20 165 653
136 : General Motors 16 038 177
137 : Melco E 001 T90 272 0 2-1
141 : E!A (Thomson) 20 165 951 - C - IA1 1 - LD6
b 2,5 mdaN
114 Champion L82
Eyquem 755 X 0 Ml4 x 1,25 > 0,8 -+ 0,9 mm <
0 1,5 -+ 2 mdaN
Bougicord 403 1 : 500 mm 2300 Q 3 : 825mm4150Q
2 : 700 mm 3450 $I 4 : 900 mm 455OQ
Page 252 of 648
asI f MA 2 21 O.O0/4a
IC
~ I
82 F;
r----------- E
M TMv
SM! Iv J
Kz1 5Ml I Z
z z z z z
I( AEI
dE B
1 ;
E
3 \,
LLII
.Vl
;-,
----I
46
Z
81
B9
4
1~~11~ 21 [NI~IIN~IIN 31
i?B 7 I.41
? ?
8531
Page 253 of 648
1 MA
210.0014b
u
I
.
51 &52 : Delco Remy 3 474 220
132
: EA (Thomson) 20 165 653
136 : General Motor 16 038 177
137 : Melco E 001 T90 272
0 2 -+ 2,5 mdaN
141
: E!A (Thomson) 85 095 - H - EC 002 ED 003
114
I Champion L82
Eyquem 755 X 0 Ml4 x I,25 > 0,8 + 0,9 mm <
0 I,5 -+ 2 mdaN
g Jlllllu&~ 7 Bougicord 1 : 500 mm 2300 Q
3 : 825 mm 4150 Q
+ 10
+- mm
o&" f 10% -+ 2 : 700 mm 3450 Q
4 : 900 mm 4550 Q
1)
Page 254 of 648
MA 21 O.O0/4b 2
I I I I I I I I I I I I I 1 I I I I I I I I I
1 2 3 4 S 6 1 8 9 10 11 12 13 14 15 16 17 li )l9 20 21 22 23 2~ :S :6 :7 i.3 :9 30 :I 312 :3 :L :S
8531
Page 255 of 648
CHECKING THE TRANSLSTORISED IGNlTlON
Page 256 of 648

CHECKlNG THE TRANSISTORISED IGNITION
ELECTRO-MAGNETICALLY TRIGGERED TRANSISTORISED IGNITION
PRELIMINARY CHECKS:
Inspect:
- the connection of the different leads (in particular to coil: a bad connection can cause a high voltage drop preven-
ting the current from passing into the coil primary winding (I 5 A approx),
- condition of the leads : (circuits broken, short-circuits across screening, etc.),
- condition of the sparking plugs (deposits, cracks due to overtightening),
- condition of the distributor cap (wear, cracks) and the rotor arm (loose).
Disconnect the interference suppression capacitor and the diagnosis harness, from the circuit.
Carry out a ((spark test)) with the starter motor and one plug earthed.
IMPORTANT: The module may be destroyed if one of the secondary wires is too far from the earth. CHECKING THE COIL (3) (ignition module and supply to coil disconnected):
MEASUREMENT OF Ohmmeter placed between channels No. Reading (in 0)
Primary winding resistance 1 and 4 DUCELLIER 0.76 to 0.84
BOSCH 0.74 to 0.90
Secondary coil resistance 1 4 and HT coil contact DUCELLIER 5700 to 6300
or
BOSCH 7425 to 9075
Insulation 1 or 4 and earth 00
Checking the coil power supply using a lamp or a voltmeter:
- Switch on the ignition: there should be a 12V current between the “BAT” terminal of the coil and the earth
- Switch off ignition. CHECKING THE IGNITION MODULE (2):
The module is designed to function with the ignition distributor and the coil.
- Do not operate the module without cooling (aluminium plate heat sink) or ventilation
- Do not check the module with an ohmmeter since the results will be non-significant.
Checking the module power supply using a lamp or a voltmeter:
- Disconnect the module connector
- Switch on the ignition: there should be a 12 V current between the channel 4 of the connector and the earth.
- Switch off ignition.
The low voltage ignition circuit being connected (in working order), disconnect the coil - distributor HT lead on
the distributor side and connect it up to an earthed plug: by sending short pulses ( + 12 VI to channel 5 (red wire)
from the module, sparks should occur at the plug (simulation of distributor spark current). CHECKING THE IGNITION DISTRIBUTOR (1):
Test the impulse generator with the module connector disconnected. MEASUREMENT OF:
Resistance
Earth
Insulation Ohmmeter placed between channels No. 5 and 6
2 and engine earth
5 and 2 then 5 and 3 Readings (in Q) 950 to 1250 approx.
0
m
,