Page 665 of 687
Canada
Specifications/Customer Information and Reporting Safety Defects
Declaration of Conformity
10-56
CX-90_8KG7-EA-22L_Edition1_new2022-11-17 16:05:04
Page 666 of 687
Specifications/Customer Information and Reporting Safety Defects
Declaration of Conformity
10-57
CX-90_8KG7-EA-22L_Edition1_new2022-11-17 16:05:04
Page 667 of 687
Wireless Charger (Qi)
Specifications/Customer Information and Reporting Safety Defects
Declaration of Conformity
10-58
CX-90_8KG7-EA-22L_Edition1_new2022-11-17 16:05:04
Page 668 of 687
Vehicle IdentificationNumber
The vehicle identification number
legally identifies your vehicle. The
number is on a plate attached to the
left top side of the dashboard. This
plate can easily be seen through the
windshield.
Motor Vehicle Safety
Standard Label
Specifications/Customer Information and Reporting Safety Defects
Identification Numbers
10-59
CX-90_8KG7-EA-22L_Edition1_new
2022-11-17 16:05:04
Page 669 of 687
Chassis Number
Open the cover shown in the figure to
check the chassis number.
Vehicle Emission ControlInformation Label
Specifications/Customer Information and Reporting Safety Defects
Identification Numbers
10-60
CX-90_8KG7-EA-22L_Edition1_new
2022-11-17 16:05:04
Page 670 of 687
Tire Pressure LabelEngine Number
Specifications/Customer Information and Reporting Safety Defects
Identification Numbers
10-61
CX-90_8KG7-EA-22L_Edition1_new
2022-11-17 16:05:04
Page 671 of 687
Engine
ItemSpecification
Type DOHC-16V in-line, 4-cylinder
Bore × Stroke 89.0 × 100.0 mm (3.50 × 3.94 in)
Displacement 2,488.5 ml (2,488.5 cc)
Compression ratio 13.0
Specifications/Customer Information and Reporting Safety Defects
Ve h i c l e
Specification
10-62
CX-90_8KG7-EA-22L_Edition1_new 2022-11-17 16:05:04
Page 672 of 687

Charge System
ItemServicing data
Input power 110 - 240 V AC
Rated frequency 60 Hz
Maximum rated electrical current In normal charge
32A AC
Maximum power consumption 7.2 kVA (normal charge)
Electrical leakage detection current
for control box including genuine
charge cable 5 mA
EV charge mode/Connection type Normal charge: Mode 2, Mode 3/TYPE1
Installation requirements
(information on protection against
short-circuit current and equipment
protection) Applicable laws and regulations, and standards must be followed
for protection measures against over-current and over-voltage.
Always make sure to install a ppropriate over-current protection
devices to the wiring of houses and buildings.
IP level IP44: When charge connector is connected to charge inlet
IP67 : Charging Cable
Operating temperature On Board Charger
Ambient temperature : -30 °C ( -22 °F) to 85 °C (185 °F)
coolant temperature : -30 °C ( -22 °F) to 70 °C (158 °F)
Charging Cable
Ambient temperature : -30 °C ( -22 °F) to 55 °C (131 °F)
Storage temperature On Board Charger
Ambient temperature : -40 °C ( -40 °F) to 85 °C (185 °F)
coolant temperature : -40 °C ( -40 °F) to 85 °C (185 °F)
Charging Cable
Ambient temperature : -40 °C ( -40 °F) to 80 °C (176 °F)
Applicable standards On Board Charger
EN/IEC 61851-1, EN/IEC 61851-21, EN/IEC 61851-23, UL 2202
Charging Cable
NFPA 70, NFPA 79, SAE-J 1772, UL 62, UL 817, UL 2231-1, UL
2231-2, UL 2251, UL 2594, CSA C22.2 No.280-16
Adapters Do not use an adapter with the plug and connector of the charg-
ing cable.
Do not use an extension cable.