2009 SUBARU TRIBECA lock

[x] Cancel search: lock

Page 2273 of 2453

SUBARU TRIBECA 2009 1.G Service Workshop Manual CS-21
Select Lever
CONTROL SYSTEMS
6) Remove the indicator lamp and then remove the
bulb.
7) Remove the shift lock solenoid assembly.
8) Remove the indicator assembly.
9) Remove the bulb case.
10) Rem

Page 2274 of 2453

SUBARU TRIBECA 2009 1.G Service Workshop Manual CS-22
Select Lever
CONTROL SYSTEMS
13) Remove blind A and B.
14) Remove  the  clip  while  being  careful  not  to
break the pin, and remove all switches.
15) Remove the connector from the base assemb

Page 2275 of 2453

SUBARU TRIBECA 2009 1.G Service Workshop Manual CS-23
Select Lever
CONTROL SYSTEMS
20) Remove the lock lever.
21) Remove the release rod and spring.
22) Remove the cable bracket.
23) Remove the spacer.
24) Remove the dust cover and dust cover brack

Page 2276 of 2453

SUBARU TRIBECA 2009 1.G Service Workshop Manual CS-24
Select Lever
CONTROL SYSTEMS
29) Remove the bushing.
30) Remove the selector arm assembly.
31) Remove  the  clip  while  being  careful  not  to
break the pin, then remove the shift button switc

Page 2277 of 2453

SUBARU TRIBECA 2009 1.G Service Workshop Manual CS-25
Select Lever
CONTROL SYSTEMS
D: ASSEMBLY
1) Clean all the parts before assembly.
2) Apply  grease  [Multemp  AC-D,  and  SH-W  or
equivalent]  to  each  part.  <Ref.  to  CS-2,  AT  SE-
LECT  LE

Page 2279 of 2453

SUBARU TRIBECA 2009 1.G Service Workshop Manual CS-27
Select Cable
CONTROL SYSTEMS
3) Install the plate assembly to transmission.
Tightening torque:
24.5 N·m (2.5 kgf-m, 18.1 ft-lb)
4) Install  the  washer  and  snap  pin  to  range  select
lever.

Page 2281 of 2453

SUBARU TRIBECA 2009 1.G Service Workshop Manual CS-29
AT Shift Lock Solenoid and “P” Range Switch
CONTROL SYSTEMS
5. AT Shift Lock Solenoid and 
“P” Range Switch
A: REMOVAL
NOTE:
For  removal  of  the  mode  change  switch  and  the
shift

Page 2282 of 2453

SUBARU TRIBECA 2009 1.G Service Workshop Manual CS-30
AT Shift Lock Solenoid and “P” Range Switch
CONTROL SYSTEMS
5) Disconnect the terminal of AT shift lock solenoid
from the connector, using a flat-tip screwdriver.
B: INSTALLATION
NOTE:
For i