Page 305 of 484
BE-27Body Electric SystemLighting System
Parts inspection
Dr
Combined switch conductance
1 2
3 4
5 6
7
8 9
10 11
12 13 14
15
16 17 18 NV 20 21
Terminal
function
Lamp switchOFF
Large
lamp
Dimmer
switchLower
beam
upper
beam
steering
switchLeftturnn
right turn
central
overtake1 810173729
SF
SL SK SY SJ
1 O 3 4 5 6 7
UV NM NN NO NP NQ
NR 16 17 18 19 20 21
Termina
function
Lamp switchOFF
small
lamp
large
lamp
dimmer
switchlower
beam
upper
beam
steering
switchright
turn left turn
central
over drive1871031529
1 2 3 4 5 6 7
8
9 10 11 12 13 14 15 16
terminal
function
lampswitchOFF
small lamp
large lamp
dimmer
switchlower beam
upper beam
wteering
switchright turn
left turn
central
over drive1671510891435
Br G/R G/Y B Bl/W B/Y B/W B Bl/W Bl/BrBl/W Bl/Br B B/Y B/W B G/Y G/R
Bl/W Bl/Br B B/Y B/W B G/Y G/R small
lamp
Page 306 of 484
BE-28Body Electric SystemLighting System
Combined Switch conductance (continued)
1 2 3 4 5 6 7
8
9 10 11 12 13 14 15 16Lamp switchOFF
Small
lamp
Small
lamp
Dimmer
switchLower
beam
steering
switchupper
beam
Right
to
central
overdrive16 7 15 10 8 9 1 4 3 5
Br G/W G/B B R/Bl R/B R/Y B R/Bl R
In case the conductance situation fails to satisfy the specified requirement, change the switch.
Conductance of Alarming Switch
Dr
1
2 3
Terminal
switch position13
OFF
ONG/B G/Y G/R
SF
1 2 3 4 5 6
7 8 9 10
OFF
ON8 91 2 34 56
B G/W P/G G/B P/B Br/Bl G/R G/Y2
SLDiesel SYDiesel
function Terminal
Left
steering
Terminal
switch position
Page 307 of 484
BE-29Body Electric SystemLighting System
Conductance of Alarming Switch (continued)
SL SK SY SJ
1 2 3 4
5 6 7 8switch
position
OFF
ON12 3 45678
G/B G/R G/Y Br Y W/Br B G/W
SLDiesel SYDiesel
1 2 3 4
5 6 7 8Terminal
switch
position
OFF
ON12 3 4 5 678
GG/W G/BBr
YBr/W B G/R
In case the conductance fails to satisfy the specified requirement, change the switch.
Conductance of Fog-lamp Switch
Dr
1
2
3Terminal
switch
position
OFF
ON13
BBl/B Terminal
Page 308 of 484
BE-30Body Electric SystemLighting System
Conductance of Fog-lamp Switch
SF
SF
SL SK SY SJ
SLDiesel SYDiesel
12 3 4
5S78 910Terminal
switch
position
OFF
ON25 6 73UVNM
B P/Y B G/W G/W
12
345
6Terminal
switch
position
OFF
ON
1 2 3
4
5 6Terminal
switch
position
OFF
ONROP S
G/W B_s
1 2 3
4 5 6Terminal
switch
position
OFF
ONRO P S
G/RB
BBl
12 3 456
B B W G/W W
Nothing Nothing Nothing
Nothing
Page 309 of 484
BE-31Body Electric SystemLighting System
Conductance of Large Lamp Relay
3085
878630
85
8786Terminal
status
Fixed
Load accumulator voltage
on the terminal 85,86.8586
8730
In case the conductance of above-mentioned switch fails to satisfy the specified requirement, change the switch.
Conductance of Flasher Relay
EL
B
turn signal lamp
1.Connect the positive lead from the accumulator to the
terminal B, and the cathode lead to terminal E.
2.Connect two turn signal lamps to the terminal L and E and
check the flashing situation of the two bubbles.
The turn signal lamp should flash 8510 per minute, in
case the flashing frequency fails to satisfy the specified
requirement, change the flasher relay.
3085
878630
85
8786Terminal
status
Fixed
Load accumulator voltage
on the terminal 85,86.85 86 87 30
Dr SF
SL SK SY SJ
Page 310 of 484