05±388
±
DIAGNOSTICS SFI SYSTEM(1AZ±FSE)
AVENSIS REPAIR MANUAL (RM1018E)
DTCP0136OXYGEN SENSOR CIRCUIT MALFUNCTION (BANK 1 SENSOR 2)
DTCP0156OXYGEN SENSOR CIRCUIT MALFUNCTION (BANK 2 SENSOR 2)
CIRCUIT DESCRIPTION
Refer to DTC P0130 on page 05±363.
DTC NoDTC Detection ConditionTrouble Area
P0136
P0156
If the following two conditions are satisfied at a time
(2 trip detection logic):
(a) The ECM records cycles which the vehicle driving and
stops 8 times or more.
(b) There was no change in the rich and lean outputs from heated oxygen sensor (sensor 2) for the 360 seconds un-
der air fuel ratio feedback control. (Throttle was not closed)
Open or short in heated oxygen sensor (bank 1, 2 sensor 2)
circuit
Heated oxygen sensor (bank 1, 2 sensor 2)
Heated oxygen sensor heater (bank 1, 2 sensor 2)
EFI relay
HINT:
Bank 1 refers to the No. 1 and No. 4 cylinders.
Bank 2 refers to the No. 2 and No. 3 cylinders.
Sensor 2 refers to the sensor farthest away from the engine assembly.
WIRING DIAGRAM
Refer to DTC P0130 on page 05±363.
05CKC±01
+25 %
±12.5 %
More than 0.55 V
Less than 0.4V
Case 1
Case 2
Case 3
Case 4
Output voltage of heated oxygen
sensor (sensor 1: front sensor)
Injection volume
Output voltage
Output voltage of heated oxygen
sensor (sensor 2: rear sensor)Mainly suspect
trouble area
OK
+25 %
±12.5 %
More than 0.55 V
Less than 0.4V
Injection volume
Output voltage
+25 %
±12.5 %
More than 0.55 V
Less than 0.4V
Injection volume
Output voltage
Sensor 1: front sensor
(sensor 1, heater, sensor 1
circuit)
+25 %
±12.5 %
More than 0.55 V
Less than 0.4V
Injection volume
Output voltage
+25 %
±12.5 %
Injection volume
Output voltage
NG
+25 %
±12.5 %
Injection volume
Output voltage
NG
+25 %
±12.5 %
Injection volume
Output voltage
NG
+25 %
±12.5 %
Injection volume
Output voltage
NGExtremely rich or lean actual
air±fuel ratio
(Injector, fuel pressure, gas
leakage in exhaust system,
etc.) OK
OK
OK
No reaction
No reaction
No reaction No reaction
Sensor 2: rear sensor
(sensor 2, heater, sensor 2
circuit) 05±390
± DIAGNOSTICSSFI SYSTEM (1AZ±FSE)
AVENSIS REPAIR MANUAL (RM1018E)
NOTICE:
There is a few seconds delay in the sensor 1 (front sensor) output. And there is about 20 seconds
delay in the sensor 2 (rear sensor).
The following A/F CONTROL procedure enables the technician to check and graph the voltage outputs of
both the heated oxygen sensors.
For displaying the graph indication, enter ºACTIVE TEST / A/F CONTROL / USER DATAº, then select ºO2S
B1S1 and O2S B1S2º or ºO2S B2S1 and O2S B2S2º by pressing ºYESº button and push ºENTERº button
before pressing ºF4º button.
HINT:
If different DTCs related to different systems that have terminal E2 as the ground terminal are output
simultaneously, terminal E2 may be open.
Read freeze frame data using the hand±held tester. Freeze frame data records the engine conditions
when a malfunction is detected. When troubleshooting, it is useful for determining whether the vehicle
was running or stopped, the engine was warmed up or not, the air±fuel ratio was lean or rich, etc. at
the time of the malfunction.
A62378
+BHT
E1
Component Side
B2S2
H10
B1S2
H8
±
DIAGNOSTICS SFI SYSTEM(1AZ±FSE)
05±391
AVENSIS REPAIR MANUAL (RM1018E)
1CHECK OTHER DTC OUTPUT(IN ADDITION TO DTC P0136 AND/OR P0156)
(a)Read the DTC using the hand±held tester.
Result:
Display (DTC output)Proceed to
Only ºP0136 and/or P0156º are outputA
ºP0136 or P0156º and other DTCs are outputB
HINT:
If any other codes besides ºP0136 and/or P0156º are output, perform \
the troubleshooting for those DTCs
first.
BGO TO RELEVANT DTC CHART(See page 05±309)
A
2 READ VALUE OF HAND±HELD TESTER(OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
(a) After warming up the engine, run the engine at 2,500 rpm for 3 minutes.
(b) Read the output voltage of the heated oxygen sensor (sensor 2) when the engine rpm is suddenly\
in-
creased.
HINT:
Quickly accelerate the engine to 4,000 rpm 3 times by using the accelerator ped\
al. The output voltage of heated oxygen sensor (sensor 2): Alternates from\
0.4 V or less to 0.5 V
or more.
OK Go to step 6
NG
3 INSPECT HEATED OXYGEN SENSOR(HEATER RESISTANCE)
(a) Disconnect the H8 or H10 heated oxygen sensor connec- tor.
(b) Measure the resistance between the terminals of the
heated oxygen sensor connector.
Standard (Bank 1, 2 Sensor 2):
Terminal No.Resistance
1 (HT) ± 2 (+B)11 to 16 at 20 C (68 F)
1 (HT) ± 4 (E1)No Continuity
NG REPLACE HEATED OXYGEN SENSOR
OK
A72920
Reference (Bank 1 Sensor 2 System Drawing)
Heated Oxygen Sensor
EFI Relay
Heater
Sensor
OX1B HT1B
Duty
Control ECM
From
Battery
EFI Fuse
O1B± EFI No. 2
Fuse
MREL OX HT
E1 +B
± DIAGNOSTICSSFI SYSTEM (1AZ±FSE)
05±393
AVENSIS REPAIR MANUAL (RM1018E)
NG REPAIR OR REPLACE HARNESS OR
CONNECTOR
OK
REPLACE HEATED OXYGEN SENSOR
6 PERFORM CONFIRMATION DRIVING PATTERN
HINT:
Clear all DTCs prior to performing the confirmation driving pattern.
GO
7 READ OUTPUT DTC(DTC P0136 AND/OR P0156 ARE OUTPUT AGAIN)
(a) Read the DTC using the hand±held tester.
Result:
Display (DTC output)Proceed to
ºP0136 and/or P0156º are not output againA
ºP0136 and/or P0156º are output againB
B REPLACE HEATED OXYGEN SENSOR
A
CHECK FOR INTERMITTENT PROBLEMS
05±374
±
DIAGNOSTICS SFI SYSTEM(1AZ±FSE)
AVENSIS REPAIR MANUAL (RM1018E)
DTCP0133OXYGEN SENSOR CIRCUIT SLOW RESPONSE (BANK 1 SENSOR 1)
DTCP0153OXYGEN SENSOR CIRCUIT SLOW RESPONSE (BANK 2 SENSOR 1)
CIRCUIT DESCRIPTION
Refer to DTC P0130 on page 05±363.
DTC No.DTC Detection ConditionTrouble Area
P0133
P0153
Response time for output voltage of heated oxygen sensor
(sensor 1) to change from rich to lean, or from lean to rich, is
1.0 sec. or more during idling after engine is warmed up
(2 trip detection logic)
Open or short in heated oxygen sensor (bank 1, 2 sensor 1)
circuit
Heated oxygen sensor (bank 1, 2 sensor 1)
Heated oxygen sensor heater (bank 1, 2 sensor 1)
EFI relay
Air induction system
Fuel pressure
Injector
ECM
HINT:
Bank 1 refers to the No. 1 and No. 4 cylinders.
Bank 2 refers to the No. 2 and No. 3 cylinders.
Sensor 1 refers to the sensor closest to the engine assembly.
WIRING DIAGRAM
Refer to DTC P0130 on page 05±363.
INSPECTION PROCEDURE
HINT:
Hand±held tester only:
Narrowing down the trouble area is possible by performing the ºA/F CONTROLº ACTIVE TEST (heated oxy-
gen sensor or other trouble areas can be distinguished).
(a) Perform ACTIVE TEST using the hand±held tester (A/F CONTROL).
HINT:
ºA/F CONTROLº is an ACTIVE TEST which changes the injection volume\
±12.5 % or +25 %.
(1) Connect the hand±held tester to the DLC3 on the vehicle.
(2) Turn the ignition switch ON.
(3) Warm up the engine by running the engine at 2,500 rpm for approximately 9\
0 sec.
(4) Select the item ºDIAGNOSIS / OBD/MOBD / ACTIVE TEST / A/F CONTROLº\
.
(5) Perform ºA/F CONTROLº with the engine in an idle condition (press\
the right or left button).
Result:
Heated oxygen sensor reacts in accordance with increase and decrease of injection volume:
+25 % rich output: More than 0.55 V
±12.5 % lean output: Less than 0.4 V
NOTICE:
There is a few seconds delay in the sensor 1 (front sensor) output. And there is about 20 seconds
delay in the sensor 2 (rear sensor).
05CKA±01
+25 %
±12.5 %
More than 0.55 V
Less than 0.4V
Case 1
Case 2
Case 3
Case 4
Output voltage of heated oxygen
sensor (sensor 1: front sensor)
Injection volume
Output voltage
Output voltage of heated oxygen
sensor (sensor 2: rear sensor)Mainly suspect
trouble area
OK
+25 %
±12.5 %
More than 0.55 V
Less than 0.4V
Injection volume
Output voltage
+25 %
±12.5 %
More than 0.55 V
Less than 0.4V
Injection volume
Output voltage
Sensor 1: front sensor
(sensor 1, heater, sensor 1
circuit)
+25 %
±12.5 %
More than 0.55 V
Less than 0.4V
Injection volume
Output voltage
+25 %
±12.5 %
Injection volume
Output voltage
NG
+25 %
±12.5 %
Injection volume
Output voltage
NG
+25 %
±12.5 %
Injection volume
Output voltage
NG
+25 %
±12.5 %
Injection volume
Output voltage
NGExtremely rich or lean actual
air±fuel ratio
(Injector, fuel pressure, gas
leakage in exhaust system,
etc.) OK
OK
OK
No reaction
No reaction
No reaction No reaction
Sensor 2: rear sensor
(sensor 2, heater, sensor 2
circuit)
± DIAGNOSTICSSFI SYSTEM (1AZ±FSE)
05±375
AVENSIS REPAIR MANUAL (RM1018E)
The following A/F CONTROL procedure enables the technician to check and graph the voltage outputs of
both the heated oxygen sensors.
For displaying the graph indication, enter ºACTIVE TEST / A/F CONTROL / USER DATAº, then select ºO2S
B1S1 and O2S B1S2º or ºO2S B2S1 and O2S B2S2º by pressing ºYESº button and push ºENTERº button
before pressing ºF4º button.
NOTICE:
If the vehicle is short of fuel, the air±fuel ratio becomes LEAN and DTCs P0133 and/or P0153 will be
recorded, and the CHK ENG then comes on.
HINT:
If different DTCs related to different systems that have terminal E2 as the ground terminal are output
simultaneously, terminal E2 may be open.
Read freeze frame data using the hand±held tester. Freeze frame data records the engine conditions
when a malfunction is detected. When troubleshooting, it is useful for determining whether the vehicle
was running or stopped, the engine was warmed up or not, the air±fuel ratio was lean or rich, etc. at
the time of the malfunction.
A high heated oxygen sensor (sensor 1) voltage (0.55 V or more) could be caused by a rich air fuel
mixture. Check for conditions that would cause the engine to run rich.
A low heated oxygen sensor (sensor 1) voltage (0.4 V or less) could be caused by a lean air fuel mix-
ture. Check for conditions that would cause the engine to run lean.
A62378
Component Side
+B
HT
E1
B1S1 H7
A61830
+B
HT
E1 Component Side
B2S1 H9
B16200
± DIAGNOSTICSSFI SYSTEM (1AZ±FSE)
05±377
AVENSIS REPAIR MANUAL (RM1018E)
4 READ OUTPUT DTC(DTC P0133 AND/OR P0153 ARE OUTPUT AGAIN)
(a) Read the DTC using the hand±held tester.
Result:
Display (DTC output)Proceed to
ºP0133 and/or P0153º are output againA
ºP0133 and/or P0153º are not output againB
B CHECK FOR INTERMITTENT PROBLEMS
A
REPLACE HEATED OXYGEN SENSOR
5 INSPECT HEATED OXYGEN SENSOR(HEATER RESISTANCE)
(a) Disconnect the H7 or H9 heated oxygen sensor connec-
tor.
(b) Measure the resistance between the terminals of the
heated oxygen sensor connector.
Standard (Bank 1, 2 Sensor 1):
Terminal No.Resistance
1 (HT) ± 2 (+B)11 to 16 at 20C (68F)
1 (HT) ± 4 (E1)No Continuity
NG REPLACE HEATED OXYGEN SENSOR
OK
6 INSPECT EFI RELAY
(a) Remove the EFI relay from the engine room R/B No. 4.
(b) Inspect the EFI relay.
Standard:
Terminal No.Specified condition
1 ± 2Continuity
No Continuity
3 ± 5Continuity
(Apply battery voltage terminals 1 and 2)
A76821
Wire Harness Side
B1S1B2S1 H7 H9
Heated Oxygen Sensor Connector OX
HT
OX
HT
E1E1
A76823
OX2A
ECM Connector E12
OX1A
HT2A HT1A
E2 E13
A72920
Reference (Bank 1 Sensor 1 System Drawing)
Heated Oxygen Sensor
EFI Relay
Heater
Sensor
OX1A HT1A
Duty
Control ECM
From
Battery
EFI Fuse
E2 EFI No. 2
Fuse
MREL OX HT
E1 +B
05±378
± DIAGNOSTICSSFI SYSTEM (1AZ±FSE)
AVENSIS REPAIR MANUAL (RM1018E)
NG REPLACE EFI RELAY
OK
7 CHECK HARNESS AND CONNECTOR(HEATED OXYGEN SENSOR ± ECM)
(a) Disconnect the H7 or H9 heated oxygen sensor connec-
tor.
(b) Disconnect the E12 and E13 ECM connectors.
(c) Check for continuity between the wire harness side con-
nectors.
Standard (Check for open):
Symbols (Terminal No.)Specified condition
OX (H7±3) ± OX1A (E12±22)
HT (H7±1) ± HT1A (E12±5)
E1 (H7±4) ± E2 (E13±28)ContinuityOX (H8±3) ± OX2A (E12±23)Continuity
HT (H8±1) ± HT2A (E12±4)
E1 (H8±4) ± E2 (E13±28)
Standard (Check for short):
Symbols (Terminal No.)Specified condition
OX (H7±3) or OX1A (E12±22) ± Body ground
HT (H7±1) or HT1A (E12±5) ± Body groundNo continuityOX (H8±3) or OX2A (E12±23) ± Body groundNo continuity
HT (H8±1) or HT2A (E12±4) ± Body ground
HINT:
The OX1A and HT1A means the heated oxygen sensor
bank 1 sensor 1.
The OX2A and HT2A means the heated oxygen sensor
bank 2 sensor 1.
NG REPAIR OR REPLACE HARNESS OR
CONNECTOR
OK