HEADLAMP - XENON TYPE -
LT-7
C
D
E
F
G
H
I
J
L
MA
B
LT
With the ignition switch in the ON or START position, power is supplied
to ignition relay (located in IPDM E/R),
through 10A fuse [No. 1, located in fuse block (J/B)]
to BCM terminal 38,
through 10A fuse [No. 14, located in fuse block (J/B)]
to combination meter terminal 8.
With the ignition switch in ACC or ON position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM terminal 11.
Ground is supplied
to BCM terminal 52 and
to combination meter terminals 10, 11 and 12
through grounds M71 and M72,
to IPDM E/R terminals 38 and 60
through grounds E1 and E31.
LOW BEAM OPERATION
When the lighting switch is in 2ND position, BCM detects the HEAD LAMP1 and 2 (ON) by BCM combination
switch reading function. BCM sends low beam request signal (ON) through CAN communication.
When receiving low beam request signal (ON), IPDM E/R turns ON headlamp low relay in IPDM E/R. IPDM E/
R supplies power
through 15A fuse (No. 76, located in IPDM E/R)
through IPDM E/R terminal 20
to front combination lamp RH terminal 1,
through 15A fuse (No. 86, located in IPDM E/R)
through IPDM E/R terminal 30
to front combination lamp LH terminal 1.
Ground is supplied
to front combination lamp RH and LH terminals 5
through grounds E1 and E31.
With power and ground supplied, low beam headlamp illuminates.
HIGH BEAM OPERATION
When the lighting switch is in HIGH BEAM position and then also in 2ND position, BCM detects the HEAD
LAMP1, 2 (ON) and the HI BEAM (ON) by BCM combination switch reading function. BCM sends low beam
request signal (ON) and high beam request signal (ON) through CAN communication.
When receiving low beam request signal (ON) and high beam request signal (ON), IPDM E/R turns ON head-
lamp low relay and headlamp high relay in IPDM E/R. And then, headlamp bulbs go ON. High beam solenoids
move the bulb shades in the front combination lamps, and the bulb shades change to high beam position.
IPDM E/R supplies power
through 15A fuse (No. 76, located in IPDM E/R)
through IPDM E/R terminal 20
to front combination lamp RH terminal 1,
through 15A fuse (No. 86, located in IPDM E/R)
through IPDM E/R terminal 30
to front combination lamp LH terminal 1,
through 10A fuse (No. 72, located in IPDM E/R)
through IPDM E/R terminal 27
to front combination lamp RH terminal 2,
through 10A fuse (No. 74, located in IPDM E/R)
through IPDM E/R terminal 28
to front combination lamp LH terminal 2.
LT-8
HEADLAMP - XENON TYPE -
Ground is supplied
to front combination lamp RH and LH terminals 5, and
to front combination lamp RH and LH terminals 4
through grounds E1 and E31.
With power and ground supplied, high beam headlamp illuminates.
The unified meter and A/C amp. receives high beam request signal (ON) through CAN communication, and
make high beam indicator lamp turn ON in combination meter.
FLASH-TO-PASS OPERATION
When the lighting switch is in PASSING position, BCM detects the PASSING (ON) by BCM combination switch
reading function. BCM sends low beam request signal (ON) and high beam request signal (ON) through CAN
communication.
When receiving low beam request signal (ON) and high beam request signal (ON), IPDM E/R turns ON head-
lamp low relay and headlamp high relay in IPDM E/R. And then, headlamp bulbs go ON. High beam solenoids
move the bulb shades in the front combination lamps to change beams from/to high and low. IPDM E/R sup-
plies power
through 15A fuse (No. 76, located in IPDM E/R)
through IPDM E/R terminal 20
to front combination lamp RH terminal 1,
through 15A fuse (No. 86, located in IPDM E/R)
through IPDM E/R terminal 30
to front combination lamp LH terminal 1,
through 10A fuse (No. 72, located in IPDM E/R)
through IPDM E/R terminal 27
to front combination lamp RH terminal 2,
through 10A fuse (No. 74, located in IPDM E/R)
through IPDM E/R terminal 28
to front combination lamp LH terminal 2.
Ground is supplied
to front combination lamp RH and LH terminals 5, and
to front combination lamp RH and LH terminals 4
through grounds E1 and E31.
With power and ground supplied, high beam headlamp illuminates.
The unified meter and A/C amp receives high beam request signal (ON) through CAN communication, and
make high beam indicator lamp turn ON in combination meter.
COMBINATION SWITCH READING FUNCTION
Refer to BCS-3, "COMBINATION SWITCH READING FUNCTION" .
EXTERIOR LAMP BATTERY SAVER CONTROL
Refer to LT- 1 9 7 , "EXTERIOR LAMP BATTERY SAVER CONTROL" .
AUTO LIGHT OPERATION
Refer to LT- 6 4 , "System Description" .
HEADLAMP - XENON TYPE -
LT-17
C
D
E
F
G
H
I
J
L
MA
B
LT
Terminals and Reference Values for IPDM E/RBKS001N1
How to Perform Trouble DiagnosisBKS001N2
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 6 , "
System Description" .
3. Perform the Preliminary Check. Refer to LT- 1 7 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Does the headlamp operate normally? If YES, GO TO 6. If NO, GO TO 4.
6. INSPECTION END
Preliminary CheckBKS001N3
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES AND FUSIBLE LINK
Check for blown fuses and fusible link.
Refer to LT- 11 , "Wiring Diagram — H/LAMP —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse or fusible link is blown, be sure to eliminate cause of malfunction before installing new fuse
or fusible link. Refer to PG-3, "
POWER SUPPLY ROUTING CIRCUIT" .
Terminal
No.Wire
colorSignal nameMeasuring condition
Reference value
Ignition
switchOperation or condition
20 R/Y Headlamp low (RH) ON Lighting switch 2ND positionOFF Approx. 0 V
ON Battery voltage
27 L/W Headlamp high (RH) ONLighting switch HIGH BEAM
or PASSING positionOFF Approx. 0 V
ON Battery voltage
28 G Headlamp high (LH) ONLighting switch HIGH BEAM
or PASSING positionOFF Approx. 0 V
ON Battery voltage
30 L Headlamp low (LH) ON Lighting switch 2ND positionOFF Approx. 0 V
ON Battery voltage
38 B Ground ON — Approx. 0 V
48 L CAN− H— — —
49 P CAN− L— — —
60 B Ground ON — Approx. 0 V
Unit Power source Fuse and fusible link No.
BCMBatteryM
17
Ignition switch ACC or ON position 6
Ignition switch ON or START position 1
IPDM E/R Battery72
74
76
86
HEADLAMP - XENON TYPE -
LT-23
C
D
E
F
G
H
I
J
L
MA
B
LT
4. CHECK CIRCUIT BETWEEN IPDM E/R AND FRONT COMBINATION LAMP
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and front combination lamp (RH and LH) connector.
3. Check continuity between IPDM E/R harness connector (A) and
front combination lamp (RH and LH) harness connector (B).
4. Check harness continuity between IPDM E/R harness connector
(A) and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
CircuitAB
Continuity
Connector Terminal Connector Terminal
RH
E727 E15 2
Ye s
LH 28 E29 2
A
GroundContinuity
Connector Terminal
RH
E727
No
LH 28
PKID0079E
LT-24
HEADLAMP - XENON TYPE -
5. CHECK IPDM E/R OUTPUT VOLTAGE
With CONSULT-II
1. Connect IPDM E/R connector.
2. Select “IPDM E/R” on CONSULT-II, and select “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Select “LAMPS” on “SELECT TEST ITEM” screen.
4. Touch “HI” screen.
5. When high beam headlamp is operating, check voltage between
IPDM E/R harness connector and ground (Headlamp perform
the HIGH-LOW changeover operation without illuminating the
headlamp bulb).
Without CONSULT-II
1. Connect front IPDM E/R connector.
2. Start auto active test. Refer to PG-21, "
Auto Active Test" .
3. When high beam headlamp is operating, check voltage between IPDM E/R harness connector and
ground.
OK or NG
OK >> GO TO 6.
NG >> Replace IPDM E/R. Refer to PG-28, "
Removal and Installation of IPDM E/R" .
6. CHECK CIRCUIT BETWEEN FRONT COMBINATION LAMP AND GROUND
1. Turn ignition switch OFF.
2. Check continuity between front combination lamp (RH and LH)
harness connector and ground.
OK or NG
OK >> Replace front combination lamp. Refer to LT- 3 6 ,
"Removal and Installation" .
NG >> Repair harness or connector.
Te r m i n a l s
Voltage
(Approx.) (+)
(-)
IPDM E/R connector Terminal
RH
E727
Ground Battery voltage
LH 28
Te r m i n a l s
Voltage
(Approx.) (+)
(-)
IPDM E/R connector Terminal
RH
E727
Ground Battery voltage
LH 28
PKID0080E
Front combination lamp
connectorTerminal
GroundContinuity
RH E15 4
Ye s
LH E29 4
SKIB8819E
HEADLAMP - XENON TYPE -
LT-25
C
D
E
F
G
H
I
J
L
MA
B
LT
Headlamp Does Not Change To High (One Side)BKS001N7
1. CHECK CIRCUIT BETWEEN IPDM E/R AND FRONT COMBINATION LAMP
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and front combination lamp RH or LH connector.
3. Check continuity between IPDM E/R harness connector (A) and
front combination lamp RH or LH harness connector (B).
4. Check harness continuity between IPDM E/R harness connector
(A) and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair harness or connector.
2. CHECK IPDM E/R OUTPUT VOLTAGE
With CONSULT-II
1. Select “IPDM E/R” on CONSULT-II, and select “ACTIVE TEST” on “SELECT DIAG MODE” screen.
2. Select “LAMPS” on “SELECT TEST ITEM” screen.
3. Touch “HI” screen.
4. When high beam headlamp is operating, check voltage between
IPDM E/R harness connector and ground (Headlamp perform
the HIGH-LOW changeover operation without illuminating the
headlamp bulb).
Without CONSULT-II
1. Start auto active test. Refer to PG-21, "
Auto Active Test" .
2. When high beam headlamp is operating, check voltage between IPDM E/R harness connector and
ground.
OK or NG
OK >> GO TO 3.
NG >> Replace IPDM E/R. Refer to PG-28, "
Removal and Installation of IPDM E/R" .
CircuitAB
Continuity
Connector Terminal Connector Terminal
RH
E727 E15 2
Ye s
LH 28 E29 2
A
GroundContinuity
Connector Terminal
RH
E727
No
LH 28
PKID0079E
Terminals
Voltage
(Approx.) (+)
(-)
IPDM E/R connector Terminal
RH
E727
Ground Battery voltage
LH 28
Terminals
Voltage
(Approx.) (+)
(-)
IPDM E/R connector Terminal
RH
E727
Ground Battery voltage
LH 28
PKID0080E
LT-28
HEADLAMP - XENON TYPE -
4. CHECK CIRCUIT BETWEEN IPDM E/R AND FRONT COMBINATION LAMP
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and front combination lamp (RH and LH) connector.
3. Check continuity between IPDM E/R harness connector (A) and
front combination lamp (RH and LH) harness connector (B).
4. Check continuity between IPDM E/R harness connector (A) and
ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK IPDM E/R OUTPUT VOLTAGE
With CONSULT-II
1. Connect IPDM E/R connector.
2. Select “IPDM E/R” on CONSULT-II, and select “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Select “LAMPS” on “SELECT TEST ITEM” screen.
4. Touch “LO” screen.
5. When low beam headlamp is operating, check voltage between
IPDM E/R harness connector and ground.
Without CONSULT-II
1. Connect IPDM E/R connector.
2. Start auto active test. Refer to PG-21, "
Auto Active Test" .
3. When low beam headlamp is operating, check voltage between IPDM E/R harness connector and ground.
OK or NG
OK >> GO TO 6.
NG >> Replace IPDM E/R. Refer to PG-28, "
Removal and Installation of IPDM E/R" .
CircuitAB
Continuity
Connector Terminal Connector Terminal
RH
E720 E15 1
Ye s
LH 30 E29 1
A
GroundContinuity
Connector Terminal
RH
E720
No
LH 30
PKID0082E
Terminals
Voltage
(Approx.) (+)
(-)
IPDM E/R connector Terminal
RH
E720
Ground Battery voltage
LH 30
Terminals
Voltage
(Approx.) (+)
(-)
IPDM E/R connector Terminal
RH
E720
Ground Battery voltage
LH 30
PKID0083E
HEADLAMP - XENON TYPE -
LT-29
C
D
E
F
G
H
I
J
L
MA
B
LT
6. CHECK CIRCUIT BETWEEN FRONT COMBINATION LAMP AND GROUND
1. Turn ignition switch OFF.
2. Check continuity between front combination lamp (RH and LH)
harness connector and ground.
OK or NG
OK >> Check headlamp harness and connectors, ballasts (HID
control unit), and xenon bulbs. Refer to LT- 3 2 , "
Xenon
Headlamp Trouble Diagnosis" .
NG >> Repair harness or connector.
Headlamp Does Not Illuminate (One Side)BKS001NA
1. CHECK BULB
Check ballasts (HID control unit) and xenon bulb of lamp which does not illuminate. Refer to LT- 3 2 , "
Xenon
Headlamp Trouble Diagnosis" .
OK or NG
OK >> GO TO 2.
NG >> Repair malfunctioning parts.
2. CHECK CIRCUIT BETWEEN IPDM E/R AND FRONT COMBINATION LAMP
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and front combination lamp RH or LH connector.
3. Check continuity between IPDM E/R harness connector (A) and
front combination lamp RH or LH harness connector (B).
4. Check continuity between IPDM E/R harness connector (A) and
ground.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
Front combination lamp
connectorTe r m i n a l
GroundContinuity
RH E15 5
Ye s
LH E29 5
PKIA6272E
CircuitAB
Continuity
Connector Terminal Connector Terminal
RH
E720 E15 1
Ye s
LH 30 E29 1
A
GroundContinuity
Connector Terminal
RH
E720
No
LH 30
PKID0082E