1997 SSANGYONG KORANDO battery

[x] Cancel search: battery

Page 269 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual D AEW OO M Y_2000
SECTION 1G1
M162 ENGINE INTAKE & EXHAUST
CAUTION: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily com

Page 275 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual M162 ENGINE INTAKE & EXHAUST 1G1 -- 7
D AEW OO M Y_2000
INTAKE MANIFOLD
Preceding Work: Removal of fuel rail
Removal of battery
Removal of canister
1 Bolt (M6 X 40, 4 pieces)
9--11 NSm (80-- 97 lb-in)

Page 284 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual 1A2 -- 12 GENERAL ENGINE INFORMATION
D AEW OO M Y_2000
Leakage Test
1. Warm the engine up to normal operating tempera-
ture.
2. Disconnect the negative battery cable.
3. Remove the spark plugs.
4. Che

Page 285 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual GENERAL ENGINE INFORMATION 1A2 -- 13
D AEW OO M Y_2000
GENERAL INFORMATION
CLEANLINESS AND CARE
An automobile engine is a combination of many ma-
chined, honed, polished and lapped surfaces with toler

Page 294 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual D AEW OO M Y_2000
SECTION 1B2
M161 ENGINE MECHANICAL
CAUTION: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in c

Page 301 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual 1B2 -- 8 M161 ENGINE MECHANICAL
D AEW OO M Y_2000
Removal & Installation Procedure
1. Disconnect the negative terminal of battery.
2. Remove the hood.
3. Remove the under cover.
Installation Notice
Ti

Page 311 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual 1B2 -- 18 M161 ENGINE MECHANICAL
D AEW OO M Y_2000
GENERATOR
1 Bolt (M8 X 40, 3 pieces)
22.5-- 27.5 NSm (16.6-- 20.3 lb-ft) .............
2 Bolt (M8 X 70, 2 pieces)
22.5-- 27.5 NSm (16.6-- 20.3 lb-ft)

Page 396 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual D AEW OO M Y_2000
SECTION 1D2
M161 ENGINE COOLING
CAUTION: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in cont