1997 SSANGYONG KORANDO battery

[x] Cancel search: battery

Page 412 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual D AEW OO M Y_2000
SECTION 1E2
M161 ENGINE ELECTRICAL
CAUTION: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in c

Page 413 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual 1E 2 -- 2 M161 ENGINE ELECTRICAL
D AEW OO M Y_2000
SPECIFICATIONS
GENERATOR SPECIFICATIONS
ApplicationDescription
Current11 5 A
Output Voltage12 -- 14 v
Resistance Between Rotor Core and Slip Ring∞

Page 414 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual M161 ENGINE ELECTRICAL 1E 2 -- 3
D AEW OO M Y_2000
MAINTENANCE AND REPAIR
ON-VEHICE SERVICE
GENERATOR
Preceding Work : Removal of the drivebelt
Removal & Installation Procedure
1. Disconnect the negat

Page 415 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual 1E 2 -- 4 M161 ENGINE ELECTRICAL
D AEW OO M Y_2000
STARTING MOTOR
Removal & Installation Procedure
1. Disconnect the ground cable.
2. Unscrew the nut and disconnect the battery cable (1).
Installation

Page 416 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual M161 ENGINE ELECTRICAL 1E 2 -- 5
D AEW OO M Y_2000
BATTERY
1 Cable Terminal ( -- )
2 Cable Terminal Cap ( -- )
3 Cable Terminal Cap (+)
4Nut
5 Fuseblink Box
6 Terminal (+)7 Battery holddown Bracket
8

Page 420 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual M161 ENGINE ELECTRICAL 1E 2 -- 9
D AEW OO M Y_2000
Removal & Installation Procedure
1. Disconnect the battery negative cable.
2. Unscrew the 3 screws and remove the ignition cable
duct cover.
Installa

Page 422 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual M161 ENGINE ELECTRICAL 1E 2 -- 11
D AEW OO M Y_2000
UNIT REPAIR
BATTERY
Inspection
Notice
DWhen charging the battery, do not leave the inflam-
mable objects around it.
DWhen checking the electrolyte o

Page 423 of 2053

SSANGYONG KORANDO 1997  Service Repair Manual D AEW OO M Y_2000
SECTION 1F2
ENGINE CONTROLS
CAUTION: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in contact