2006 DODGE RAM SRT-10 engine

[x] Cancel search: engine

Page 77 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10.4 volts.
Set Condition:
The TIPM has detected on overcurrent condition in the Starter Control circuit. One Trip Fault. Three good

Page 78 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 4.(T40) STARTER RELAY OUTPUT CIRCUIT SHORTED TO GROUND
Disconnect the C9 TIPM harness connector.
Measure the resistance between ground and the (T40) Starter Relay Output circuit at the C9 TIPM harness

Page 80 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10.4 volts.
Set Condition:
A shorted low condition in the Fuel Pump Control circuit has been detected by the TIPM. One Trip Fault. Th

Page 81 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.(A109) FUEL PUMP CONTROL OUTPUT CIRCUIT SHORTED TO GROUND
Turn the ignition off
Disconnect the C10 TIPM harness connector.
Disconnect the Fuel Pump Module harness connector.
Measure the resistance b

Page 83 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10.4 volts.
Set Condition:
A shorted high condition in the Fuel Pump Control circuit has been detectedin the TIPM. One Trip Fault. Th

Page 84 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.(A109) FUEL PUMP CONTROL OUTPUT CIRCUIT SHORTED TO BATTERY VOLTAGE
Turn the ignition off
Disconnect the C10 TIPM harness connector.
Disconnect the Fuel Pump Module harness connector.
Ignition on, en

Page 85 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 6.TOTALLY INTEGRATED POWER MODULE
NOTE: Before continuing, check the TIPM harness connector terminals for corrosion, damage, or terminal
push out. Repair as necessary.
Using the schematics as a guide,

Page 87 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10.4 volts. TIPM requesting Fuel Pump operation.
Set Condition:
An open condition has been detected in the Fuel Pump Control circuit