EC-242
[QG (WITH EURO-OBD)]
DTC P0340 CMP SENSOR (PHASE)
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureEBS00K8G
1. CHECK STARTING SYSTEM
Turn ignition switch to “START” position.
Ye s o r N o
Yes >> GO TO 2.
No >> Check starting system. (Refer to SC-13.)
2. RETIGHTEN GROUND SCREWS
1. Turn ignition switch “OFF”.
2. Loosen and retighten engine ground screws.
>> GO TO 3.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
14 RCamshaft position
sensor (PHASE)[Engine is running]
●Warm-up condition
●Idle speed1.0 - 4.0V
[Engine is running]
●Engine speed is 2,000 rpm.1.0 - 4.0V
29 BCamshaft position
sensor (PHASE)
ground[Engine is running]
●Idle speedApproximately 0V
PBIB0525E
PBIB0526E
Does the engine turn over?
Does the starter motor operate?
MBIB0095E
DTC P0340 CMP SENSOR (PHASE)
EC-243
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
3.CHECK CMP SENSOR (PHASE) POWER SUPPLY CIRCUIT
1. Disconnect camshaft position (CMP) sensor (PHASE) harness
connector.
2. Turn ignition switch “ON”.
3. Check voltage between CMP sensor (PHASE) terminal 3 and
ground with CONSULT-II or tester.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4.DETECT MALFUNCTIONING PART
Check the following.
●Harness connectors E225, F43
●Harness for open or short between camshaft position sensor (PHASE) and ECM
●Harness for open or short between camshaft position sensor (PHASE) and ECM relay
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK CMP SENSOR (PHASE) GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 29 and CMP sensor (PHASE) terminal 1.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 6.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
6.CHECK CMP SENSOR (PHASE) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 14 and CMP sensor (PHASE) terminal 2.
Refer to Wiring Diagram.
2. Also check harness for short to ground or short to power.
OK or NG
OK >> GO TO 7.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
MBIB0104E
Voltage: Battery voltage
SEF509Y
Continuity should exist.
Continuity should exist.
EC-246
[QG (WITH EURO-OBD)]
DTC P0420 THREE WAY CATALYST FUNCTION
DTC P0420 THREE WAY CATALYST FUNCTION
PFP:20905
On Board Diagnosis LogicEBS00K8J
The ECM monitors the switching frequency ratio of heated oxygen
sensors 1 and 2.
A three way catalyst (Manifold) with high oxygen storage capacity
will indicate a low switching frequency of heated oxygen sensor 2.
As oxygen storage capacity decreases, the heated oxygen sensor 2
switching frequency will increase.
When the frequency ratio of heated oxygen sensors 1 and 2
approaches a specified limit value, the three way catalyst (Manifold)
malfunction is diagnosed.
DTC Confirmation ProcedureEBS00K8K
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
TESTING CONDITION:
●Open engine hood before conducting the following procedure.
●Do not hold engine speed for more than the specified minutes below.
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch ″OFF″ and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least one minute under no
load.
4. Let engine idle for one minute.
5. Select “DTC & SRT CONFIRMATION” then “SRT WORK SUP-
PORT” mode with CONSULT-II.
6. Rev engine up to 2,500 to 3,500 rpm and hold it for 3 consecu-
tive minutes then release the accelerator pedal completely.
If “INCMP” of “CATALYST” changed to “COMPLT”, go to step 9
7. Wait 5 seconds at idle.
SEF484YF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0420
0420Catalyst system efficiency
below threshold
●Three way catalyst (Manifold) does not operate
properly.
●Three way catalyst (Manifold) does not have
enough oxygen storage capacity.
●Three way catalyst (Manifold)
●Exhaust tube
●Intake air leaks
●Fuel injectors
●Fuel injector leaks
●Spark plug
●Improper ignition timing
PBIB0566E
EC-248
[QG (WITH EURO-OBD)]
DTC P0420 THREE WAY CATALYST FUNCTION
5. Set voltmeters probes between ECM terminal 35 (HO2S1 sig-
nal) and engine ground, and ECM terminal 16 (HO2S2 signal)
and engine ground.
6. Keep engine speed at 2,000 rpm constant under no load.
7. Make sure that the voltage switching frequency (high & low)
between ECM terminal 16 and engine ground is very less than
that of ECM terminal 35 and engine ground.
Switching frequency ratio = A/B
A: Heated oxygen sensor 2 voltage switching frequency
B: Heated oxygen sensor 1 voltage switching frequency
This ratio should be less than 0.75.
If the ratio is greater than above, it means three way catalyst
does not operate properly. Go to EC-248, "
Diagnostic Proce-
dure" .
NOTE:
If the voltage at terminal 35 does not switch periodically more than 5
times within 10 seconds at step 7, perform trouble diagnosis for “DTC P0133” first. (See EC-155
.)
Diagnostic ProcedureEBS00K8M
1. CHECK EXHAUST SYSTEM
Visually check exhaust tubes and muffler for dent.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace.
2. CHECK EXHAUST GAS LEAK
1. Start engine and run it at idle.
2. Listen for an exhaust gas leak before the three way catalyst (manifold).
OK or NG
OK >> GO TO 3.
NG >> Repair or replace.
MBIB0018E
MBIB0124E
SEC502D
DTC P0420 THREE WAY CATALYST FUNCTION
EC-249
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
3.CHECK INTAKE AIR LEAK
Listen for an intake air leak after the mass air flow sensor.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace.
4.CHECK IGNITION TIMING
Check the following items. Refer to EC-65, "
Basic Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Follow the “Basic Inspection”.
5.CHECK INJECTORS
1. Refer to Wiring Diagram for Injectors, EC-376
.
2. Stop engine and then turn ignition switch “ON”.
3. Check voltage between ECM terminals 22, 23, 41, 42 and
ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 6.
NG >> Perform EC-377, "
Diagnostic Procedure" .
6.CHECK IGNITION SPARK
1. Turn ignition switch “OFF”.
2. Disconnect ignition coil assembly from rocker cover.
3. Connect a known-good spark plug to the ignition coil assembly.
4. Place end of spark plug against a suitable ground and crank engine.
5. Check for spark.
OK or NG
OK >> GO TO 7.
NG >> Check ignition coil with power transistor and their circuit.
Refer to EC-365, "
IGNITION SIGNAL" .
Items Specifications
Ignition timingM/T: 8°± 5° BTDC
A/T: 10°± 5° BTDC
(in “P” or “N” position)
Target idle speedM/T: 700 ± 50 rpm
A/T: 800 ± 50 rpm
(in “P” or “N” position)
Battery voltage should exist.
MBIB0030E
SEF575Q
DTC P0444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-251
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC P0444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
PFP:14920
DescriptionEBS00K8N
SYSTEM DESCRIPTION
*1: This signal is sent to the ECM through CAN communication line.
*2: The ECM determines the start signal status by the signals of engine speed and battery voltage.
This system controls flow rate of fuel vapor from the EVAP canister. The opening of the vapor by-pass pas-
sage in the EVAP canister purge volume control solenoid valve changes to control the flow rate. The EVAP
canister purge volume control solenoid valve repeats ON/OFF operation according to the signal sent from the
ECM. The opening of the valve varies for optimum engine control. The optimum value stored in the ECM is
determined by considering various engine conditions. When the engine is operating, the flow rate of fuel vapor
from the EVAP canister is regulated as the air flow changes.
COMPONENT DESCRIPTION
The EVAP canister purge volume control solenoid valve uses a ON/
OFF duty to control the flow rate of fuel vapor from the EVAP canis-
ter. The EVAP canister purge volume control solenoid valve is
moved by ON/OFF pulses from the ECM. The longer the ON pulse,
the greater the amount of fuel vapor that will flow through the valve.
CONSULT-II Reference Value in Data Monitor ModeEBS00K8O
Specification data are reference values.
Sensor Input Signal to ECM ECM Function Actuator
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE)Engine speed
*2
EVAP canister
purge flow controlEVAP canister purge
volume control solenoid
valve Mass air flow sensor Amount of intake air
Engine coolant temperature sensor Engine coolant temperature
Battery
Battery voltage*2
Throttle position sensor Throttle position
Accelerator pedal position sensor Closed throttle position
Heated oxygen sensors 1Density of oxygen in exhaust gas
(Mixture ratio feedback signal)
Vehicle speed signal
*1Vehicle speed
SEF337U
MONITOR ITEM CONDITION SPECIFICATION
PURG VOL C/V
●Engine: After warming up
●Shift lever:
N (A/T models)
Neutral (M/T models)
●Air conditioner switch: OFF
●No-loadIdle 0%
2,000 rpm 15 - 30%
EC-252
[QG (WITH EURO-OBD)]
DTC P0444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
On Board Diagnosis Logic
EBS00K8P
DTC Confirmation ProcedureEBS00K8Q
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Turn ignition switch “ON”.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and let it idle for at least 13 seconds.
4. If 1st trip DTC is detected, go to EC-254, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0444
0444EVAP canister purge volume
control solenoid valve circuit
openAn excessively low voltage signal is sent
to ECM through the valve
●Harness or connectors
(The solenoid valve circuit is open or
shorted.)
●EVAP canister purge volume control
solenoid valve
SEF058Y
EC-254
[QG (WITH EURO-OBD)]
DTC P0444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureEBS00K8S
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1. Turn ignition switch “OFF”.
2. Disconnect EVAP canister purge volume control solenoid valve
harness connector.
3. Turn ignition switch “ON”.
4. Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
19 GY/LEVAP canister purge
volume control solenoid
valve[Engine is running]
●Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
●Engine speed is about 2,000 rpm (More than
100 seconds after starting engine).Approximately 10V
PBIB0050E
PBIB0520E
MBIB0113E
Voltage: Battery voltage
PBIB0148E