2003 NISSAN ALMERA N16 ecm

[x] Cancel search: ecm

Page 533 of 3189

NISSAN ALMERA N16 2003  Electronic Repair Manual DTC P0221 TP SENSOR
EC-203
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
2.CHECK THROTTLE POSITION SENSOR POWER SUPPLY CIRCUIT
1. Disconnect electric throttle control actuator harness connector.
2. T

Page 534 of 3189

NISSAN ALMERA N16 2003  Electronic Repair Manual EC-204
[QG (WITH EURO-OBD)]
DTC P0221 TP SENSOR
6. REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
1. Replace the electric throttle control actuator.
2. Perform EC-31, "
Throttle Valve Closed Position

Page 535 of 3189

NISSAN ALMERA N16 2003  Electronic Repair Manual DTC P0222, P0223 TP SENSOR
EC-205
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC P0222, P0223 TP SENSORPFP:16119
Component DescriptionEBS00K76
Electric  Throttle  Control  Actuator  consists  of

Page 538 of 3189

NISSAN ALMERA N16 2003  Electronic Repair Manual EC-208
[QG (WITH EURO-OBD)]
DTC P0222, P0223 TP SENSOR
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measurin

Page 539 of 3189

NISSAN ALMERA N16 2003  Electronic Repair Manual DTC P0222, P0223 TP SENSOR
EC-209
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
2.CHECK THROTTLE POSITION SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnect electric throttle control actuator harness connec

Page 540 of 3189

NISSAN ALMERA N16 2003  Electronic Repair Manual EC-210
[QG (WITH EURO-OBD)]
DTC P0222, P0223 TP SENSOR
6. REPLACE ELECTRIC THROTTLE CONTROL ACTUATOR
1. Replace the electric throttle control actuator.
2. Perform EC-31, "
Throttle Valve Closed Po

Page 541 of 3189

NISSAN ALMERA N16 2003  Electronic Repair Manual DTC P0226 APP SENSOR
EC-211
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC P0226 APP SENSORPFP:18002
Component DescriptionEBS00K7E
The  accelerator  pedal  position  sensor  is  installed  on  the

Page 544 of 3189

NISSAN ALMERA N16 2003  Electronic Repair Manual EC-214
[QG (WITH EURO-OBD)]
DTC P0226 APP SENSOR
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring inpu