Page 2526 of 4323

I08311
2
1
I28970
Resistance (kW)
Temperature
4.0
2.0 3.5
1.5
0.0
10 3.0
1.0 2.5
0.5
20 30 40 5060
68 86 104 122140
(C)
(F) 50
DI±2324
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2518 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check ambient temperature sensor.
PREPARATION:
Disconnect the ambient temperature sensor connector.
CHECK:
Measure the resistance between terminals 1 and 2 of the ambi-
ent temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±210C (50F)3.00 to 3.73 kW
1±215C (59F)2.45 to 2.88 kW
1±220C (68F)1.95 to 2.30 kW
1±225C (77F)1.60 to 1.80 kW
1±230C (86F)1.28 to 1.47 kW
1±235C (95F)1.00 to 1.22 kW
1±240C (104F)0.80 to 1.00 kW
1±245C (113F)0.65 to 0.85 kW
1±250C (122F)0.50 to 0.70 kW
1±255C (131F)0.44 to 0.60 kW
1±260C (140F)0.36 to 0.50 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace ambient temperature sensor.
OK
3 Check harness and connector between ambient temperature sensor and integra-
tion control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2528 of 4323
I28847
SG±TE TEI20 Integration Control and Panel:
DI±2326
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2520 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
1 Check voltage between terminals TE and SG±TE of integration control and pan-
el.
PREPARATION:
Remove the integration control and panel with connectors still
connected.
CHECK:
(a) Turn the ignition switch to ON.
(b) Measure the voltage between terminals TE and SG±TE
of the integration control and panel connector at each
temperature.
OK:
Voltage :
at 0°C (32°F) : 2.0 to 2.4 V
at 15°C (59°F) : 1.4 to 1.8 V
HINT:
As the temperature increases, the voltage decreases.
NG Go to step 2.
OK
Proceed to next circuit inspection shown in problem symptoms table (See page DI±2304). How-
ever, if DTC 13 is displayed, replace integration control and panel.
Page 2529 of 4323

N16207
Thermometer
Ice
More than
10 cm (3.94in.)1
2
I28971Temperature Resistance (kW)
9.0 10.0
8.0
5.07.0
4.0
2.0 3.0
0.0
14 32 50 68 86 ±10 0 10 20 30
(F) (C) 6.0
1.0
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2327
2521 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check front evaporator temperature sensor.
PREPARATION:
Remove the front evaporator temperature sensor.
CHECK:
Measure the resistance between terminals 1 and 2 of the evap-
orator temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±2±10C (14F)7.40 to 9.20 kW
1±2±5C (23F)5.65 to 7.00 kW
1±20C (32F)4.35 to 5.40 kW
1±25C (41F)3.40 to 4.20 kW
1±210C (50F)2.68 to 3.30 kW
1±215C (59F)2.10 to 2.60 kW
1±220C (68F)1.66 to 2.10 kW
1±225C (77F)1.32 to 1.66 kW
1±230C (86F)1.05 to 1.35 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace front evaporator temperature sensor.
OK
3 Check harness and connector between front evaporator temperature sensor and
integration control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2533 of 4323
I28847
RrSG
RrTEI21 Integration Control and Panel:
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2331
2525 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
1 Check voltage between terminals RrTE and RrSG of integration control and pan-
el.
PREPARATION:
Remove the integration control and panel with connectors still
connected.
CHECK:
(a) Turn the ignition switch to ON.
(b) Measure the voltage between terminals RrTE and RrSG
of the integration control and panel connector at each
temperature.
OK:
Voltage :
at 0°C (32°F) : 2.0 to 2.4 V
at 15°C (59°F) : 1.4 to 1.8 V
HINT:
As the temperature increases, the voltage decreases.
NG Go to step 2.
OK
Proceed to next circuit inspection shown in problem symptoms table (See page DI±2304). How-
ever, if DTC 17 is displayed, replace integration control and panel.
Page 2534 of 4323

N16207
Thermometer
Ice
More than
10 cm (3.94in.)1
2
I28971Temperature Resistance (kW)
9.0 10.0
8.0
5.07.0
4.0
2.0 3.0
0.0
14 32 50 68 86 ±10 0 10 20 30
(F) (C) 6.0
1.0
DI±2332
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2526 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check rear evaporator temperature sensor.
PREPARATION:
Remove the rear evaporator temperature sensor (See page
AC±42).
CHECK:
Measure the resistance between terminals 1 and 2 of the evap-
orator temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±2±10C (14F)7.40 to 9.20 kW
1±2±5C (23F)5.65 to 7.00 kW
1±20C (32F)4.35 to 5.40 kW
1±25C (41F)3.40 to 4.20 kW
1±210C (50F)2.68 to 3.30 kW
1±215C (59F)2.10 to 2.60 kW
1±220C (68F)1.66 to 2.10 kW
1±225C (77F)1.32 to 1.66 kW
1±230C (86F)1.05 to 1.35 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace rear evaporator temperature sensor.
OK
3 Check harness and connector between rear evaporator temperature sensor and
integration control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2536 of 4323
I28847
RrTR SG±RrTRI22 Integration Control and Panel:
DI±2334
± DIAGNOSTICSAIR CONDITIONING SYSTEM
2528 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
1 Check voltage between terminals RrTR and SG±RrTR of integration control and
panel.
PREPARATION:
Remove the integration control and panel with connectors still
connected.
CHECK:
(a) Turn the ignition switch to ON.
(b) Measure the voltage between terminals RrTR and SG±
RrTR of the integration control and panel connector at
each temperature.
OK:
Voltage :
at 25°C (77°F) : 1.8 to 2.2 V
at 40°C (104°F) : 1.2 to 1.6 V
HINT:
As the temperature increases, the voltage decreases.
NG Go to step 2.
OK
Proceed to next circuit inspection shown in problem symptoms table (See page DI±2304). How-
ever, if DTC19 is displayed, replace integration control and panel.
Page 2537 of 4323

I08309
21
I28970
Resistance (kW)
Temperature
4.0
2.0 3.5
1.5
0.0
10 3.0
1.0 2.5
0.5
20 30 40 5060
68 86 104 122140
(C)
(F) 50
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2335
2529 Author: Date:
2005 SEQUOIA (RM1146U)
2 Check rear room temperature sensor.
PREPARATION:
Disconnect the rear room temperature sensor connector.
CHECK:
Measure the resistance between terminals 1 and 2 of the room
temperature sensor connector at each temperature.
OK:
Tester connectionConditionSpecified condition
1±210C (50F)3.00 to 3.73 kW
1±215C (59F)2.45 to 2.88 kW
1±220C (68F)1.95 to 2.30 kW
1±225C (77F)1.60 to 1.80 kW
1±230C (86F)1.28 to 1.47 kW
1±235C (95F)1.00 to 1.22 kW
1±240C (104F)0.80 to 1.00 kW
1±245C (113F)0.65 to 0.85 kW
1±250C (122F)0.50 to 0.70 kW
1±255C (131F)0.44 to 0.60 kW
1±260C (140F)0.36 to 0.50 kW
NOTICE:
Even slightly touching the sensor may change the re-
sistance value. Be sure to hold the connector of the
sensor.
When measuring, the sensor temperature must be
the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see
the graph on the left).
NG Replace rear room temperature sensor.
OK
3 Check harness and connector between rear room temperature sensor and in-
tegration control and panel (See page IN±35).
NG Repair or replace harness or connector.
OK
Replace integration control and panel.
Page 2539 of 4323
I28847
TS
S5±TRI20 Integration Control and Panel:
± DIAGNOSTICSAIR CONDITIONING SYSTEM
DI±2337
2531 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
1 Check voltage between terminals TS and S5±TS of integration control and panel.
PREPARATION:
Remove the integration control and panel with connectors still
connected.
CHECK:
(a) Turn the ignition switch to ON.
(b) Measure the voltage between terminals TS and S5±TS of
the integration control and panel connector when the so-
lar sensor is subjected to an electric light, and when the
sensor is covered by a cloth.
OK:
ConditionVoltage
Move the light away from the sensorVoltage increases
Move the light closer to the sensorVoltage decreases
HINT:
Use an incandescent lamp for inspection. Bring it within 30 cm
(11.8 in.) of the solar sensor.
NG Go to step 2.
OK
Proceed to next circuit inspection shown in problem symptoms table (See page DI±2304). How-
ever, if DTC 21 is displayed, replace integration control and panel.