Page 844 of 4284

Symptom:
IOD WAKE UP OPEN - PLG
When Monitored and Set Condition:
IOD WAKE UP OPEN - PLG
When Monitored: Anytime the Body Control Module is awake.
Set Condition: If the BCM does not sense a signal circuit from the Liftgate Module this
code will set.
POSSIBLE CAUSES
DTC PRESENT
BODY CONTROL MODULE - IOD WAKE UP OPEN
LIFTGATE MODULE WAKE UP SIGNAL WIRE OPEN
LIFTGATE MODULE WAKE UP SIGNAL WIRE SHORT TO GROUND
POWER LIFTGATE MODULE
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Wait 10 seconds.
With the DRBIIIt, read DTCs.
Does the DRBIIItdisplay IOD WAKE UP OPEN?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the BCM C2 connector.
Measure the voltage between the Liftgate Module Wake Up Signal circuit and
ground.
Is the voltage above 10.0 volts?All
Ye s®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
3 Disconnect the Body Control Module C2 connector.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance of the Liftgate Module Wake Up Signal circuit between the
BCM C2 connector and the Power Liftgate Module C2 connector.
Is the resistance below 5.0 ohms?All
Ye s®Go To 4
No®Repair the Liftgate Module Wake Up Signal wire for an open.
Perform BODY VERIFICATION TEST - VER 1.
815
POWER DOORS - LIFTGATE
Page 846 of 4284
Symptom:
LOOPBACK TEST FAILURE
When Monitored and Set Condition:
LOOPBACK TEST FAILURE
When Monitored: Anytime the Power Liftgate Module is awake.
Set Condition: The Power Liftgate Module did not receive its own transmitted message
on the PCI bus back (loopback) for longer than 1 second.
POSSIBLE CAUSES
DTC PRESENT
POWER LIFTGATE MODULE
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times from stop to stop if possible.
With the DRBIIIt, read ACTIVE DTCs.
Does the DRBIIItdisplay LOOPBACK TEST FAILURE?All
Ye s®Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
door several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.
817
POWER DOORS - LIFTGATE
Page 847 of 4284
Symptom:
LOSS OF BCM MESSAGES
When Monitored and Set Condition:
LOSS OF BCM MESSAGES
When Monitored: Whenever the ignition is on.
Set Condition: If the PLG Module losses communication with the BCM for over 5 seconds,
this code will set.
POSSIBLE CAUSES
ATTEMPT TO COMMUNICATE WITH THE BODY CONTROL MODULE
POWER LIFTGATE MODULE - LOSS OF BCM MESSAGES
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, enter Body then Body Computer.
Was the DRBIIItable to I/D or communicate with the BCM?All
Ye s®Go To 2
No®Refer to the Communication category for the related symptom(s).
2 With the DRBIIIt, erase DTC's.
Cycle the ignition switch from off to on and wait approximately 1 minute.
With the DRBIIIt, read DTC's.
Did this DTC reset?All
Ye s®Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Test Complete.
818
POWER DOORS - LIFTGATE
Page 848 of 4284
Symptom:
LOSS OF EATX MESSAGES
When Monitored and Set Condition:
LOSS OF EATX MESSAGES
When Monitored: Whenever the ignition is in the UNLOCK or RUN position.
Set Condition: If the PLG Module does not receive a PRNDL message for over 5 seconds,
this code will set.
POSSIBLE CAUSES
ATTEMPT TO COMMUNICATE WITH THE TRANSMISSION CONTROL MODULE
POWER LIFTGATE MODULE - LOSS OF EATX MESSAGES
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIItselect Transmission.
Was the DRBIIItable to I/D or communicate with the Transmission?All
Ye s®Go To 2
No®Refer to the Communication category for the related symptom(S).
2 With the DRBIIIt, erase DTC's.
Cycle the ignition switch from off to on and wait approximately 1 minute.
With the DRBIIIt, read DTC's.
Did this DTC reset?All
Ye s®Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Test Complete.
819
POWER DOORS - LIFTGATE
Page 849 of 4284
Symptom:
LOSS OF FCM MESSAGES
When Monitored and Set Condition:
LOSS OF FCM MESSAGES
When Monitored: Whenever the ignition is in the RUN position.
Set Condition: If the PLG Module does not receive a temperature message from the Front
Control Module for over 5 seconds, this code will set.
POSSIBLE CAUSES
ATTEMPT TO COMMUNICATE WITH THE FRONT CONTROL MODULE
POWER LIFTGATE MODULE - LOSS OF FCM MESSAGES
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, enter Body then Front Control Module.
Was the DRBIIItable to I/D or communicate with the FCM?All
Ye s®Go To 2
No®Refer to the Communication category for the related symptom(S).
2 With the DRBIIIt, erase DTC's.
Cycle the ignition switch from off to on and wait approximately 1 minute.
With the DRBIIIt, read DTC's.
Did this DTC reset?All
Ye s®Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Test Complete.
820
POWER DOORS - LIFTGATE
Page 850 of 4284
Symptom:
LOSS OF SBEC MESSAGES
When Monitored and Set Condition:
LOSS OF SBEC MESSAGES
When Monitored: Whenever the ignition is in the RUN position.
Set Condition: If the PLG Module does not receive a speed message from the Powertrain
Control Module for over 5 seconds, this code will set.
POSSIBLE CAUSES
ATTEMPT TO COMMUNICATE WITH THE POWERTRAIN CONTROL MODULE
POWER LIFTGATE MODULE - LOSS OF SBEC MESSAGES
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, select Engine.
Was the DRBIIItable to I/D or communicate with the Powertrain Control Module?All
Ye s®Go To 2
No®Refer to the Communication category for the related symptom(S).
2 With the DRBIIIt, erase DTC's.
Cycle the ignition switch from off to on and wait approximately 1 minute.
With the DRBIIIt, read DTC's.
Did this DTC reset?All
Ye s®Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.
No®Test Complete.
821
POWER DOORS - LIFTGATE
Page 852 of 4284

Symptom:
OUTSIDE LIFTGATE HANDLE INPUT STUCK
When Monitored and Set Condition:
OUTSIDE LIFTGATE HANDLE INPUT STUCK
When Monitored: Whenever the Body Control Module is awake.
Set Condition: When the BCM senses a liftgate handle input on the Liftgate Handle
Switch Sense circuit for longer than 10 seconds this code will set.
POSSIBLE CAUSES
LIFTGATE HANDLE SWITCH STUCK
LIFTGATE HANDLE SWITCH SENSE CIRCUIT SHORT TO GROUND
BODY CONTROL MODULE - LIFTGATE HANDLE SWITCH SHORT TO GROUND
TEST ACTION APPLICABILITY
1 Disconnect the License Lamp connector (light bar).
With the DRBIIIt, erase DTCs.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Wait 10 seconds.
With the DRBIIIt, read DTCs.
Does the DRBIIItdisplay Outside Liftgate Handle Input Stuck?All
Ye s®Go To 2
No®Replace the Liftgate Handle Switch.
Perform BODY VERIFICATION TEST - VER 1.
2 Disconnect the License Lamp connector.
Disconnect the Body Control Module C2 connector.
Measure the resistance between ground and the Liftgate Handle Switch Sense
circuit.
Is the resistance below 10000.0 ohms?All
Ye s®Repair the Liftgate Handle Switch Sense circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
3 If there are no possible causes remaining, view repair. All
Repair
Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
823
POWER DOORS - LIFTGATE
Page 853 of 4284

Symptom:
OVERHEAD LIFTGATE SWITCH INPUT STUCK
When Monitored and Set Condition:
OVERHEAD LIFTGATE SWITCH INPUT STUCK
When Monitored: Whenever the BCM is awake.
Set Condition: When the BCM senses a overhead liftgate switch input for over 10
seconds, this code will set.
POSSIBLE CAUSES
DTC PRESENT
OVERHEAD LIFTGATE SWITCH SHORTED
LIFTGATE SWITCH MUX WIRE SHORT TO GROUND
BODY CONTROL MODULE - OVERHEAD LIFTGATE SWITCH MUX SHORTED
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the Liftgate from the Overhead Console Switch.
With the DRBIIIt, read DTCs.
Does the DRBIIItdisplay OVERHEAD LIFTGATE SWITCH INPUT STUCK?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.
2 With the DRBIIIt, erase DTCs.
Disconnect the Overhead Console Switch connector.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Wait 10 seconds.
With the DRBIIIt, read DTCs.
Does the DRBIIItdisplay OVERHEAD LIFTGATE SWITCH INPUT STUCK?All
No®Replace the Power Sliding Door Button Module.
Perform BODY VERIFICATION TEST - VER 1.
Ye s®Go To 3
3 Disconnect the Body Control Module C2 connector.
Disconnect the Overhead Console Switch connector.
Measure the resistance of the Liftgate Switch Mux circuit to ground.
Is the resistance below 4000.0 ohms?All
Ye s®Repair the Liftgate Switch Mux wire for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
824
POWER DOORS - LIFTGATE