Symptom:
INCOMPLETE LATCH RELEASE- SECTOR GEAR RETURN FAIL-
URE
When Monitored and Set Condition:
INCOMPLETE LATCH RELEASE- SECTOR GEAR RETURN FAILURE
When Monitored: Whenever the power liftgate is operating.
Set Condition: If the cinch release motor takes longer than 700 ms to perform a release
operation this code will set. The main causes of this code setting is some type of sticking
situation preventing the sector gear in the cinch release motor assembly to return to its
neutral position.
POSSIBLE CAUSES
DTC PRESENT
BINDING LIFTGATE
LIFTGATE CINCH RELEASE MOTOR ASSEMBLY
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times if possible.
With the DRBIIIt, read ACTIVE DTCs.
Does the DRBIIItdisplay INCOMPLETE LATCH RELEASE - SECTOR GEAR
RETURN FAILURE?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
door several times and check for any binding or other obstruc-
tions.
Perform BODY VERIFICATION TEST - VER 1.
2 Examine the liftgate for proper fit and alignment, loose/hard or torn seals, struts or
anything that would cause an obstruction to proper operation.
Manually operate the liftgate of a known good vehicle and notice the effort needed to
open and close.
Compare the effort needed on the disabled liftgate.
Especially notice the effort needed to unlatch and close the liftgate.
Does it take more effort to operate the liftgate than it should?All
Ye s®Refer to Service information for the related symptom(s).
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Liftgate Cinch Release Motor Assembly..
Perform BODY VERIFICATION TEST - VER 1.
790
POWER DOORS - LIFTGATE

Symptom:
INCOMPLETE POWER CLOSE - FULL OPEN SWITCH FAILURE
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - FULL OPEN SWITCH FAILURE
When Monitored: Whenever the power liftgate is closing.
Set Condition: The Full Open Switch was detected as closed before 200 hall effect pulses
were counted since the start of the close operation. May be triggered by an intermittent full
open switch failure, or non gear engagement
POSSIBLE CAUSES
DTC PRESENT
OBSTRUCTION OR STICKING FULL OPEN SWITCH
FULL OPEN SWITCH SHORT TO GROUND
POWER LIFTGATE MOTOR ASSEMBLY - FULL OPEN SWITCH
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times if possible.
With the DRBIIIt, read ACTIVE DTCs.
Does the DRBIIItdisplay INCOMPLETE POWER CLOSE - FULL OPEN SWITCH
FAILURE?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
liftgate several times and check for any binding cables or other
obstructions.
Perform BODY VERIFICATION TEST - VER 1.
2 Examine the liftgate for proper fit and alignment, foreign material in the drive unit
or anything that would cause an obstruction to proper operation of the Full Open
Switch.
With the DRBIIItin Inputs/Outputs, read the FULL OPEN SWITCH state.
Manually operate the liftgate while monitoring the DRBIIIt.
Does the switch status change smoothly as the liftgate is pulled down from the full
open position.All
Ye s®Go To 3
No®Refer to Service information for the related symptom(S).
Perform BODY VERIFICATION TEST - VER 1.
791
POWER DOORS - LIFTGATE

Symptom:
INCOMPLETE POWER CLOSE - MISSING HALL SIGNAL
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - MISSING HALL SIGNAL
When Monitored: Anytime the power liftgate is in the closing cycle.
Set Condition: If the Power Liftgate Module detects a missing hall effect signal for longer
than 300 ms. during a closing operation, this code will set. This is a redundant safety
feature in the software and will set if the obstacle detection feature becomes inoperative
due to a hall sensor/connection malfunction.
POSSIBLE CAUSES
DTC PRESENT
POWER LIFTGATE MODULE - HALL EFFECT OPEN
BINDING LIFTGATE
HALL EFFECT GROUND CIRCUIT OPEN
LIFTGATE HALL EFFECT SUPPLY WIRE OPEN
LIFTGATE HALL EFFECT SUPPLY WIRE SHORT TO GROUND
LIFTGATE HALL EFFECT SUPPLY WIRE SHORT TO HARNESS GROUND
LIFTGATE HALL EFFECT SIGNAL WIRE OPEN
LIFTGATE HALL EFFECT SIGNAL WIRE SHORT TO GROUND
LIFTGATE HALL EFFECT SIGNAL WIRE SHORT TO HARNESS GROUND
POWER LIFTGATE MOTOR ASSEMBLY
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times from stop to stop if possible.
With the DRBIIIt, read ACTIVE DTCs.
Does the DRBIIItdisplay INCOMPLETE POWER CLOSE - MISSING HALL
SIGNAL?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
liftgate several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.
793
POWER DOORS - LIFTGATE

Symptom:
INCOMPLETE POWER CLOSE - OVER CURRENT
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - OVER CURRENT
When Monitored: Anytime the liftgate is in a closing operation.
Set Condition: The drive motor stall current of over 24 amps has been detected for over
500 ms. during a close operation.
POSSIBLE CAUSES
DTC PRESENT
BINDING LIFTGATE
GROUND CIRCUIT OPEN
LIFTGATE CLOSE DRIVER CIRCUIT SHORT TO GROUND
LIFTGATE LATCH RELEASE DRIVER CIRCUIT SHORT TO GROUND
LIFTGATE LATCH RELEASE DRIVER CIRCUIT SHORT TO HARNESS GROUND
LIFTGATE GEAR ENGAGE DRIVER CIRCUIT SHORT TO GROUND
LIFTGATE GEAR ENGAGE DRIVER CIRCUIT SHORT TO HARNESS GROUND
LIFTGATE MODULE
POWER LIFTGATE MOTOR
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times (if possible).
With the DRBIIIt, read DTCs.
Does the DRBIIItdisplay INCOMPLETE POWER CLOSE- OVERCURRENT?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
liftgate several times and check for any binding conditions.
Perform BODY VERIFICATION TEST - VER 1.
2 Examine the liftgate for proper alignment, worn or binding hinges, weak or binding
liftgate prop rods, loose/ hard weatherstrip, and gear teeth on the power liftgate
motor assembly for wear or anything that would cause an obstruction to proper
operation.
Compare the effort needed on the disabled vehicle.
Especially notice the effort needed to unlatch and close the liftgate.
Does it take more effort to operate the liftgate than it should?All
Ye s®Refer to Service information for the related symptom(s).
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 3
796
POWER DOORS - LIFTGATE

TEST ACTION APPLICABILITY
3 Turn the ignition off.
Disconnect the Power Liftgate Module C1 connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Wiggle the harness and check for an intermittent open condition.
Does the test light illuminate brightly?All
Ye s®Go To 4
No®Repair the Ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
4 Turn the ignition off.
Disconnect the Power Liftgate Module C1 connector.
Measure the resistance between ground and the Liftgate Close Driver circuit.
Wiggle the harness and check for an intermittent short circuit condition.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Liftgate Close Driver circuit for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 5
5 Turn the ignition off.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance between ground and the Liftgate Latch Release Driver
circuit.
Wiggle the harness and check for an intermittent short condition.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Liftgate Latch Release Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 6
6 Turn the ignition off.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance between the Ground circuit (cavity 20) and the Liftgate Latch
Release Driver circuit.
Wiggle the harness and check for an intermittent short condition.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Liftgate Latch Release Driver circuit for a short to the
Ground circuit.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 7
7 Turn the ignition off.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance between ground and the Liftgate Gear Engage Driver circuit.
Wiggle the harness and check for an intermittent short condition.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Liftgate Gear Engage Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 8
797
POWER DOORS - LIFTGATE
INCOMPLETE POWER CLOSE - OVER CURRENT ÐContinued

TEST ACTION APPLICABILITY
8 Turn the ignition off.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance between the Ground circuit (cavity 20) and the Liftgate Gear
Engage Driver circuit.
Wiggle the harness and check for an intermittent short condition.
Is the resistance below 1000.0 ohms?All
Ye s®Repair the Liftgate Gear Engage Driver circuit for a short to the
Ground circuit.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 9
9 Ensure all module and motor connectors are connected at this time.
Try to operate the liftgate in the close position.
Did the motor start to close the liftgate but was very slow and labored extensively?All
Ye s®Replace the Power Liftgate Motor assembly.
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Power Liftgate Module
Perform BODY VERIFICATION TEST - VER 1.
798
POWER DOORS - LIFTGATE
INCOMPLETE POWER CLOSE - OVER CURRENT ÐContinued

Symptom:
INCOMPLETE POWER CLOSE - TIME OUT
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - TIME OUT
When Monitored: During Power Liftgate close cycle.
Set Condition: The power close operation was not completed within 20 seconds. This may
be caused by very high closing effort. A weak hall effect signal, low motor output or high
prop rod pressure could also set this code.
POSSIBLE CAUSES
DTC PRESENT
BINDING DOOR
POWER LIFTGATE MOTOR ASSEMBLY
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times from stop to stop - if possible.
With the DRBIIIt, read ACTIVE DTCs.
Does the DRBIIItdisplay INCOMPLETE POWER CLOSE - TIME-OUT?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
liftgate several times and check for any binding or other obstruc-
tions.
Perform BODY VERIFICATION TEST - VER 1.
2 Examine the liftgate for proper alignment, worn or binding hinges, weak liftgate prop
assembly, loose/ hard weatherstrip, and gear teeth on the power liftgate motor
assembly for wear or anything that would cause an obstruction to proper operation.
If necessary manually operate the power liftgate on a known good vehicle and notice
the effort needed to open and close for comparison.
Especially notice the effort needed to unlatch and close the liftgate.
Does it take more effort to operate the liftgate than it should?All
Ye s®Refer to Service information for the related symptom(s).
Perform BODY VERIFICATION TEST - VER 1.
No®Replace the Power Liftgate Motor Assembly.
Perform BODY VERIFICATION TEST - VER 1.
799
POWER DOORS - LIFTGATE

Symptom:
INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE
When Monitored and Set Condition:
INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE
When Monitored: During the Power Liftgate open cycle.
Set Condition: The Full Open Switch was detected as closed before 200 hall effect pulses
were counted since the start of the open operation. May be triggered by an intermittent full
open switch failure or a non gear engagement.
POSSIBLE CAUSES
DTC PRESENT
OBSTRUCTION OR STICKING FULL OPEN SWITCH
FULL OPEN SWITCH SHORT TO GROUND
POWER LIFTGATE MOTOR ASSEMBLY - FULL OPEN SWITCH
TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTC's.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power liftgate several times if possible.
With the DRBIIIt, read ACTIVE DTCs.
Does the DRBIIItdisplay INCOMPLETE POWER OPEN - FULL OPEN SWITCH
FAILURE?All
Ye s®Go To 2
No®Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition. Operate the
liftgate several times and check for any binding or obstructions.
Perform BODY VERIFICATION TEST - VER 1.
2 Examine the liftgate for proper fit and alignment, foreign material in the drive unit
or anything that would cause an obstruction to proper operation of the Full Open
Switch.
With the DRBIIItin Inputs/Outputs, read the FULL OPEN SWITCH state.
Manually operate the liftgate while monitoring the DRBIIIt.
Does the switch status change smoothly as the liftgate is pulled down from the full
open position.All
Ye s®Go To 3
No®Refer to Service information for the related symptom(S).
Perform BODY VERIFICATION TEST - VER 1.
800
POWER DOORS - LIFTGATE