2001 CHRYSLER VOYAGER ignition

[x] Cancel search: ignition

Page 795 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND
When Monitored and Set Condition:
AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND
When Monitored: Whenever the Power Liftgate Module is a

Page 798 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
INCOMPLETE LATCH CINCH - NO CURRENT
When Monitored and Set Condition:
INCOMPLETE LATCH CINCH - NO CURRENT
When Monitored: During the liftgate closing operation.
Set Condition: The cinch opera

Page 799 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
3 Turn the ignition off.
Disconnect the Liftgate Cinch/Release Motor connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit (cavity 4).
Wiggle

Page 800 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
INCOMPLETE LATCH CINCH - NO PAWL TRANSITION
When Monitored and Set Condition:
INCOMPLETE LATCH CINCH - NO PAWL TRANSITION
When Monitored: Whenever the power liftgate in performing a cinching

Page 802 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
INCOMPLETE LATCH CINCH - OVERCURRENT
When Monitored and Set Condition:
INCOMPLETE LATCH CINCH - OVERCURRENT
When Monitored: Whenever the power liftgate is performing a cinching operation.
Set

Page 803 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
3 Turn the ignition off.
Disconnect the Power Liftgate Module C2 connector.
Disconnect the Liftgate Cinch/Release Motor connector.
Measure the resistance of the Liftgate Latc

Page 804 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
7 Turn the ignition off.
Disconnect the Power Liftgate Module C2 connector.
Disconnect the Liftgate Cinch/Release Motor connector.
Measure the resistance between ground and t

Page 805 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
INCOMPLETE LATCH CINCH - PAWL SWITCH FAILURE
When Monitored and Set Condition:
INCOMPLETE LATCH CINCH - PAWL SWITCH FAILURE
When Monitored: During the liftgate close operation.
Set Condition: