2001 CHRYSLER VOYAGER ignition

[x] Cancel search: ignition

Page 892 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
1 With the DRBIIIt, record and erase DTCs.
Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the power sliding door several times if possible.
With

Page 895 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
14 Disconnect the Sliding Door Control Module C2 connector.
Disconnect the Sliding Door Latch Sensing Switch connector.
Measure the resistance of the both Ground wires betwee

Page 896 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
19 Turn the ignition off.
Disconnect the Sliding Door Control Module C2 connector.
Disconnect the Cinch/Release Motor connector.
Measure the resistance of the Cinch/Release M

Page 897 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
INCOMPLETE POWER CLOSE - MISSING HALL SIGNAL
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - MISSING HALL SIGNAL
When Monitored: Anytime the power sliding door is in the closing cy

Page 900 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
INCOMPLETE POWER CLOSE - OVERCURRENT
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - OVERCURRENT
When Monitored: Anytime the Power Sliding Door is operating in the closing directio

Page 901 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
3 Turn the ignition off.
Disconnect the Sliding Door Control Module C1 connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Wiggle the harne

Page 902 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
INCOMPLETE POWER CLOSE - TIME OUT
When Monitored and Set Condition:
INCOMPLETE POWER CLOSE - TIME OUT
When Monitored: Anytime the Power Sliding Door is operating in the closing direction.
Set

Page 903 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE
When Monitored and Set Condition:
INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE
When Monitored: Whenever the power sliding door is operatin