TEST ACTION APPLICABILITY
5Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the ATC C2 harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
Select DRB Standalone.
Select lab scope.
Select Live.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the ATC connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?All
Ye s®Go To 6
No®Repair the PCI Bus circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
6 If there are no possible causes remaining, view repair. All
Repair
Replace the Automatic Temperature Control Module.
Perform BODY VERIFICATION TEST - VER 1.
374
COMMUNICATION
*BUS +/- SIGNALS OPEN FROM AUTOMATIC TEMPERATURE CON-
TROL MODULE Ð
Continued

TEST ACTION APPLICABILITY
4Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Turn the ignition off.
Disconnect the Memory Seat/Mirror Module C2 harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
With the DRBIIItselect Pep Module Tools.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the Memory Seat/Mirror Module connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?All
Ye s®Go To 5
No®Repair the PCI Bus circuit for an open.
Perform MEMORY SYSTEM VERIFICATION TEST - VER 1.
5 If there are no possible causes remaining, view repair. All
Repair
Replace the Memory Seat/Mirror Module.
Perform MEMORY SYSTEM VERIFICATION TEST - VER 1.
376
COMMUNICATION
*BUS +/- SIGNALS OPEN FROM MEMORY SEAT/MIRROR MODULE Ð
Continued

TEST ACTION APPLICABILITY
5Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the SKIM harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
Select DRB Standalone.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the SKIM connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?All
Ye s®Go To 6
No®Repair the PCI Bus circuit for an open.
Perform SKIS VERIFICATION.
6 If there are no possible causes remaining, view repair. All
Repair
Replace and program the Sentry Key Immobilizer Module in
accordance with the Service Information.
Perform SKIS VERIFICATION.
378
COMMUNICATION
*BUS +/- SIGNALS OPEN FROM SENTRY KEY IMMOBILIZER MODULE
Ð
Continued

TEST ACTION APPLICABILITY
4Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the BCM C3 harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
Select DRB Standalone.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the BCM connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?All
Ye s®Go To 5
No®Repair the PCI Bus circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
5 If there are no possible causes remaining, view repair. All
Repair
Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
380
COMMUNICATION
*BUS +/- SIGNALS OPEN OR NO RESPONSE FROM BODY CONTROL
MODULE Ð
Continued

TEST ACTION APPLICABILITY
4Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the A/C Heater Control C1 harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
Select DRB Standalone.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the A/C Heater Control connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?All
Ye s®Go To 5
No®Repair the PCI Bus circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
5 If there are no possible causes remaining, view repair. All
Repair
Replace the A/C Heater Control.
Perform BODY VERIFICATION TEST - VER 1.
382
COMMUNICATION
*BUS +/- SIGNALS OPEN OR NO RESPONSE FROM HVAC ÐContinued

TEST ACTION APPLICABILITY
4Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the Instrument Cluster harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
With the DRBIIItselect Pep Module Tools.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the Instrument Cluster connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?All
Ye s®Go To 5
No®Repair the PCI Bus circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
5 Turn the ignition off.
Reconnect the Instrument Cluster harness connector.
Disconnect the BCM C4 harness connector.
Turn the ignition on.
Measure the voltage of the Instrument Cluster Wake Up Sense circuit in the BCM C4
connector.
Is the voltage above 10.0 volts?All
Ye s®Go To 6
No®Go To 9
6 Turn the ignition off.
Disconnect the BCM C4 harness connector.
Turn the ignition on.
Using a 12-volt test light connected to ground, probe the Instrument Cluster Wake
Up Sense circuit.
Is the test light illuminated?All
Ye s®Go To 7
No®Go To 8
384
COMMUNICATION
*BUS +/- SIGNALS OPEN OR NO RESPONSE FROM INSTRUMENT CLUS-
TER Ð
Continued

TEST ACTION APPLICABILITY
3Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the Left Sliding Door Control Module C2 connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
Select DRB Standalone.
Select lab scope.
Select Live.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the Left Sliding Door Control Module C2 connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?All
Ye s®Go To 4
No®Repair the PCI Bus circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
4 Disconnect the Left Sliding Door Control Module C2 connector.
Turn the ignition on.
Measure the resistance between ground and the Left Sliding Door Wake Up Signal
circuit.
Is the resistance below 50.0 ohms?All
Ye s®Go To 5
No®Go To 8
5 Disconnect the Body Control Module C3 connector.
Disconnect the Left Sliding Door Module C2 connector.
Measure the voltage between the Left Sliding Door Wake Up Signal circuit and
ground.
Is there any voltage present?All
Ye s®Repair the Left Sliding Door Wake Up Signal wire for a short to
voltage.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 6
6 Disconnect the Body Control Module C3 connector.
Disconnect the Left Sliding Door Control Module C2 connector.
Measure the resistance between the Left Sliding Door Wake Up Signal circuit and
ground.
Is the resistance below 100.0 ohmsAll
Ye s®Repair the Left Sliding Door Wake Up Signal wire for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 7
387
COMMUNICATION
*BUS +/- SIGNALS OPEN OR NO RESPONSE FROM LEFT SLIDING
DOOR CONTROL MODULE Ð
Continued

TEST ACTION APPLICABILITY
3Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the Power Liftgate Module C2 connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
Select DRB Standalone.
Select lab scope.
Select Live.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the Power Liftgate Module C2 connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?All
Ye s®Go To 4
No®Repair the PCI Bus circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
4 Disconnect the Power Liftgate Module C2 connector.
Turn the ignition on.
Measure the resistance between ground and the Liftgate Module Wake Up Signal
circuit.
Is the resistance below 50.0 ohms?All
Ye s®Go To 5
No®Go To 8
5 Disconnect the Body Control Module C2 connector.
Disconnect the Power Liftgate Module C2 connector.
Measure the voltage between the Liftgate Module Wake Up Signal circuit and
ground.
Is there any voltage present?All
Ye s®Repair the Liftgate Module Wake Up Signal wire for a short to
voltage.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 6
6 Disconnect the Body Control Module C2 connector.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance between the Liftgate Module Wake Up Signal circuit and
ground.
Is the resistance below 100.0 ohmsAll
Ye s®Repair the Liftgate Module Wake Up Signal wire for a short to
ground.
Perform BODY VERIFICATION TEST - VER 1.
No®Go To 7
390
COMMUNICATION
*BUS +/- SIGNALS OPEN OR NO RESPONSE FROM POWER LIFTGATE
MODULE Ð