POOR HEATER PERFORMANCE ± EL007±00 April 14, 2000
Page 4 of 4
E. Set the temperature selector of the
heater control unit to the ªMAX.
COOLº position.
F. Connect the air mix cable connector
to the air mix link pin on the left side
of the A/C unit and clamp the outer
cable to the secure clamp.
NOTE:
It is unnecessary to push or pull the
outer cable.
Do not bend the cable when setting
the cable.
Do not move the air mix knob until
you are finished clamping the outer
cable.
1. Rotary Knob For Temperature
Control
Operate the temperature control
rotary knob after setting the cables,
check that there is a ªthumpº at the
end of the travel, and no reversing
force at ªMAX. COOLº or ªMAX. HOTº
position.
2. Air Inlet Lever
Operate air inlet lever after setting the
cable and check that there is a ªclickº
at the end of the travel and no
reversing force at ªRECIRCULATEº
and ªFRESHº positions.
3. Blower Switch, Air Flow Mode
Switch & A/C Switch
Operate each switch and make sure
they are operating correctly.
Installation
Procedure
(Continued)
MAX.
COOL
Air
Mix
Link
Inspection
Procedure