Page 553 of 557
1. Main fuse
2. Main relay
3. ECM
4. Immobilizer indicator lamp
(Vehicle not equipped with
monitor coupler)For G10 engine
For G13B engine
For G10 engine For G13B engine
IMMOBILIZER CONTROL SYSTEM 8G-15
A-3 IMMOBILIZER INDICATOR LAMP CHECK
(IMMOBILIZER INDICATOR LAMP REMAINS ON AFTER ENGINE STARTS)
STEPACTIONYESNO
11) With ignition switch OFF, disconnect
couplers from ECM.
Does immobilizer indicator lamp turn ON
at ignition switch ON?“(p)” wire shorted to
ground circuit.Substitute a known-good ECM
and recheck.
Page 554 of 557

1
1. Ignition key with built-in transponder 1. Data link connector (DLC)
8G-16 IMMOBILIZER CONTROL SYSTEM
HOW TO REGISTER IGNITION KEY
Register the ignition key with a built-in transponder in Immobilizer
Control Module by using the following procedure.
1) Prepare Suzuki scan tool (TECH 1A kit and cartridge for immobi-
lizer control system).
2) With ignition switch OFF, connect Suzuki scan tool to data link
connector (DLC) located on underside of instrument panel at
driver’s seat side.
Special Tool
(A): 09931-76011 (Tech 1A)
(B): Immobilizer cartridge
(C): 09931-76030 (16 / 14-pin DLC cable)
NOTE:
For operation procedure of Suzuki scan tool, refer to Suzuki
scan tool operator’s manual.
3) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
4) Number of Transponder codes for ignition key with a built-in
transponder that can be registered in Immobilizer Control Mod-
ule is limited to 4. If needed, clear all Transponder codes for igni-
tion key with a built-in transponder that have been registered in
Immobilizer Control Module by executing the “CLR. TRANS
COD (CLEAR TP CODE)” command in the SELECT MODE
menu by using Suzuki scan tool.
NOTE:
When “CLR. TRANS COD (CLEAR TP CODE)” command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicles equipped
with the monitor coupler) ON, it remains ON even after
execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
5) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing “ENT. TRANS COD (ENT. TP
CODE)” command in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
Page 555 of 557

IMMOBILIZER CONTROL SYSTEM 8G-17
7) If any other Transponder code for ignition key with a built-in
transponder needs to be registered, repeat above Steps 3), 5)
and 6).
NOTE:
Up to 4 Transponder codes for ignition key with a built-in
transponder can be registered.
It is not possible to register the same Transponder code
for ignition key with a built-in transponder as the one al-
ready registered in Immobilizer Control Module.
PROCEDURE AFTER IMMOBILIZER
CONTROL MODULE REPLACEMENT
When Immobilizer Control Module was replaced, including when
replaced because rechecking by using a known-good Immobilizer
Control Module was necessary during trouble diagnosis, register
Transponder code and ECM / Immobilizer Control Module code in
Immobilizer Control Module and ECM / Immobilizer Control Module
code in ECM by performing following procedure.
1) Perform Steps 1) and 2) described in “How to register ignition
key” section.
2) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
3) Using Suzuki scan tool, clear all transponder codes registered
in Immobilizer Control Module by executing “CLR. TRANS COD
(CLEAR TP CODE)” command in SELECT MODE menu.
NOTE:
When “CLR. TRANS COD (CLEAR TP CODE)” command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicles equipped
with the monitor coupler) ON, it remains ON even after
execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
4) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing “ENT. TRANS COD (ENT. TP
CODE)” command in SELECT MODE menu.
5) Using Suzuki scan tool, register ECM / Immobilizer Control Mod-
ule code in both Immobilizer Control Module and ECM by
executing “RECORD ECU (RECORD ECM / PCM / ICM)” com-
mand in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
7) If any other Transponder code for ignition key with a built-in trans-
ponder needs to be registered, repeat above Steps 2), 4) and 6).
NOTE:
Up to 4 Transponder codes for ignition key with a built-in
transponder can be registered.
It is not possible to register the same Transponder code
for ignition key with a built-in transponder as the one al-
ready registered in Immobilizer Control Module.
Page 556 of 557

8G-18 IMMOBILIZER CONTROL SYSTEM
09931-76030
16 / 14 pin DLC cable
09931-76011
Suzuki scan tool (Tech 1A kit)1. Storage case
2. Operator’s manual
3. Tech 1A
4. DLC cable
(14 / 26 pin, 09931-76040)
5. Test lead / probe
6. Power source cable
7. DLC cable adapter
8. Self-test adapter
Immobilizer cartridge of
version 1.1 or more
NOTE:
Use this cable only with im-
mobilizer cartridge of ver-
sion 1.1 or more.
Use of this cable with 96
immobilizer cartridge will
disable 96 immobilizer car-
tridge from operating prop-
erly.
Mass storage cartridge of
version 1.5 or more
PROCEDURE AFTER ECM
REPLACEMENT
When ECM was replaced, including when replaced because re-
checking by using a known-good ECM was necessary during
trouble diagnosis, register ECM/Immobilizer Control Module code
in ECM by performing following procedure.
1) Perform Steps 1) and 2) described in “How to register ignition
key” section. And then turn ignition switch ON.
2) Using Suzuki scan tool, register ECM/Immobilizer Control Module
code in ECM by executing “RECORD ECU (RECORD ECM / Im-
mobilizer Control Module)” command in SELECT MODE menu.
NOTE:
For operation procedure of Suzuki scan tool, refer to Suzuki
scan tool operator’s manual.
3) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
SPECIAL TOOLS
Page 557 of 557
Prepared by
Overseas Service Department
1st Ed. July, 2000
Printed in Japan
Printing: 556