1999 SUBARU LEGACY light

[x] Cancel search: light

Page 1168 of 1456

SUBARU LEGACY 1999  Service Repair Manual 2. Inspection and Replacement
Standards
A: VEHICLES WHICH BECOME
INVOLVED IN A COLLISION
If the vehicle equipped with an SRS airbag sys-
tem is damaged in a collision, the airbag sys-
tem parts must b

Page 1171 of 1456

SUBARU LEGACY 1999  Service Repair Manual 3. Airbag Module
A: REMOVAL AND INSTALLATION
CAUTION:
IThe airbag module (driver, passenger and
side) must not be disassembled. The airbag
module cannot be used again once inflated.
G5M0299
IWhen remo

Page 1176 of 1456

SUBARU LEGACY 1999  Service Repair Manual 5. Airbag Control Module
A: REMOVAL AND INSTALLATION
CAUTION:
IDo not disassemble the airbag control mod-
ule.
G5M0322
IIf the airbag control module is deformed, or
if water damage is suspected, repla

Page 1215 of 1456

SUBARU LEGACY 1999  Service Repair Manual E: INSPECTION
Check electrodes and inner and outer porcelain of
plugs, noting the type of deposits and the degree
of electrode erosion.
G6M0086
1) Normal
Brown to grayish-tan deposits and slight elect

Page 1226 of 1456

SUBARU LEGACY 1999  Service Repair Manual 1. Body Electrical
Battery Reserve capacity 82 minutes (MT), 100 minutes (AT)
Cold cranking ampere 430 amperes (MT), 490 amperes (AT)
Fuse10 A, 15 A, 20 A
Combination meter Speedometer Electric pulse

Page 1231 of 1456

SUBARU LEGACY 1999  Service Repair Manual 4. Headlight
A: ADJUSTMENT
1. HEADLIGHT AIMING
Adjust the headlight aiming by turning the adjust-
ing screws.
CAUTION:
Before checking the headlight aiming, be sure
of the following:
ITurn off the lig

Page 1232 of 1456

SUBARU LEGACY 1999  Service Repair Manual B6M0061
4) Remove bolts which secure headlight and
remove headlight.
Tightening torque:
6.4
±0.5 N´m (0.65±0.05 kg-m, 4.7±0.4 ft-lb)
B6M0050
5) Installation is in the reverse order of removal.
3.

Page 1233 of 1456

SUBARU LEGACY 1999  Service Repair Manual D: INSPECTION
1. COMBINATION SWITCH (ON-CAR)
1) Remove instrument panel lower cover.
2) Remove lower column cover.
3) Unfasten holddown clip which secures harness, and disconnect connectors from body