Page 1991 of 3342
B2M0481
10D2CHECK HARNESS BETWEEN ECM AND
MASS AIR FLOW SENSOR CONNECTOR.
1) Turn ignition switch to OFF and Subaru Select Monitor
or the OBD-II general scan tool switch to OFF.
2) Disconnect connector from mass air flow sensor.
3) Turn ignition switch to ON and Subaru Select Monitor or
the OBD-II general scan tool switch to ON.
4) Read data on Subaru select monitor or OBD-II general
scan tool.
Subaru Select Monitor
Designate mode using function key.
Function mode: F06
: Is the value more than 250 g/sec or5Vin
function mode F06?
: Repair battery short circuit in harness between
mass air flow sensor and ECM connector. After
repair, replace ECM.
: Replace mass air flow sensor.
OBD-II general scan tool
For detailed operation procedures, refer to OBD-II General
Scan Tool Instruction Manual.
140
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostic Chart with Trouble Code for LHD Vehicles
Page 1993 of 3342

10E1CHECK DTC P0107, P0108, P1102 OR
P1122 ON DISPLAY.
: Does the Subaru select monitor or OBD-II
general scan tool indicate DTC P0107,
P0108, P1102 OR P1122?
: Inspect DTC P0107, P0108, P1102 OR P1122
using“10. Diagnostics Chart with Trouble Code”.
NOTE:
In this case, it is not necessary to inspect DTC P0106.
: Go to step10E2.
OBD0145A
10E2
CHECK DATA FOR CONTROL.
1) Turn ignition switch to OFF.
2) Connect Subaru Select Monitor or the OBD-II general
scan tool to data link connector.
3) Turn ignition switch ON and Subaru Select Monitor or
the OBD-II general scan tool switch ON.
4) Start engine.
B2M0756
5) Read data on Subaru Select Monitor or the OBD-II gen-
eral scan tool.
Subaru Select Monitor
Designate mode using function key.
Function mode: F21 and F20
F21: Display shows pressure signal value sent from the
pressure sensor.
F20: Display shows pressure signal value sent from the
pressure sensor.
: Is the value more than 85 kPa in function
mode F21?
: Go to step10E3.
: Go to next.
142
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostic Chart with Trouble Code for LHD Vehicles
Page 1997 of 3342

OBD0145A
10F1CONNECT SUBARU SELECT MONITOR
OR THE OBD-II GENERAL SCAN TOOL,
AND READ DATA.
1) Turn ignition switch to OFF.
2) Connect Subaru Select Monitor or the OBD-II general
scan tool to data link connector.
3) Turn ignition switch to ON and Subaru Select Monitor or
the OBD-II general scan tool switch to ON.
4) Start engine.
B2M0756
5) Read the data on Subaru Select Monitor or the OBD-II
general scan tool.
Subaru Select Monitor
Designate mode using function key.
Function mode: F21
F21: Display shows pressure signal value sent from
pressure sensor.
: Is the value less than 0 kPa in function
mode F21?
: Go to step10F2.
: Even if MIL lights up, the circuit has returned to a
normal condition at this time.
OBD-II general scan tool
For detailed operation procedures, refer to the OBD-II Gen-
eral Scan Tool Instruction Manual.
B2M0535A
10F2CHECK INPUT SIGNAL FOR ECM.
(USING VOLTAGE METER AND SUBARU
SELECT MONITOR.)
1) Measure voltage between ECM connector and chassis
ground.
: Connector & terminal
(B84) No. 21 (+)—Chassis ground ( ):
Is the voltage more than 4.5 V?
: Go to next step 2).
: Go to next.
146
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostic Chart with Trouble Code for LHD Vehicles
Page 1998 of 3342

B2M0535A
: Does the voltage change more than 4.5 V by
shaking harness and connector of ECM
while monitoring the value with voltage
meter?
: Repair poor contact in ECM connector.
: Contact with SOA service.
NOTE:
Inspection by DTM is required, because probable cause is
deterioration of multiple parts.
B2M0536A
2) Measure voltage between ECM and chassis ground.
: Connector & terminal
(B84) No. 26 (+)—Chassis ground ( ):
Is the voltage less than 0.2 V?
: Go to step10F3.
: Go to next step 3).
B2M0755
3) Read data on Subaru Select Monitor.
Subaru Select Monitor
Designate mode using function key.
Function mode: F20
F20: Display shows pressure signal value sent from
pressure sensor.
: Does the value change more than 0 kPa by
shaking harness and connector of ECM
while monitoring the value with Subaru
select monitor?
: Repair poor contact in ECM connector.
: Go to step10F3.
OBD0693A
10F3CHECK HARNESS BETWEEN ECM AND
PRESSURE SENSOR CONNECTOR.
1) Turn ignition switch to OFF.
2) Disconnect connector from pressure sensor.
3) Turn ignition switch to ON.
4) Measure voltage between pressure sensor connector
and engine ground.
147
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostic Chart with Trouble Code for LHD Vehicles
Page 2001 of 3342

OBD0145A
10G1CONNECT SUBARU SELECT MONITOR
OR THE OBD-II GENERAL SCAN TOOL,
AND READ DATA.
1) Turn ignition switch to OFF.
2) Connect Subaru Select Monitor or the OBD-II general
scan tool to data link connector.
3) Turn ignition switch to ON and Subaru Select Monitor or
the OBD-II general scan tool switch to ON.
4) Start engine.
B2M0756
5) Read the data on Subaru Select Monitor or the OBD-II
general scan tool.
Subaru Select Monitor
Designate mode using function key.
Function mode: F21
F21: Display shows pressure signal value sent from
pressure sensor.
: Is the value more than 140 kPa in function
mode F21?
: Go to step10G4.
: Go to step10G2.
OBD-II general scan tool
For detailed operation procedures, refer to the OBD-II Gen-
eral Scan Tool Instruction Manual.
B2M0535A
10G2CHECK INPUT SIGNAL FOR ECM.
(USING VOLTAGE METER AND SUBARU
SELECT MONITOR.)
1) Measure voltage between ECM connector and chassis
ground.
: Connector & terminal
(B84) No. 21 (+)—Chassis ground ( ):
Is the voltage more than 4.5 V?
: Go to next step 2).
: Go to next.
150
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostic Chart with Trouble Code for LHD Vehicles
Page 2002 of 3342
B2M0535A
: Does the voltage change more than 4.5 V by
shaking harness and connector of ECM
while monitoring the value with voltage
meter?
: Repair poor contact in ECM connector.
: Contact with SOA service.
NOTE:
Inspection by DTM is required, because probable cause is
deterioration of multiple parts.
B2M0536A
2) Measure voltage between ECM and chassis ground.
: Connector & terminal
(B84) No. 26 (+)—Chassis ground ( ):
Is the voltage less than 0.2 V?
: Go to step10G3.
: Go to next step 3).
B2M0755
3) Read data on Subaru Select Monitor.
Subaru Select Monitor
Designate mode using function key.
Function mode: F20
F20: Display shows pressure signal value sent from
pressure sensor.
: Does the value change more than 0 kPa by
shaking harness and connector of ECM
while monitoring the value with Subaru
select monitor?
: Repair poor contact in ECM connector.
: Go to step10G3.
151
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostic Chart with Trouble Code for LHD Vehicles
Page 2004 of 3342
B2M0756
10G4CHECK HARNESS BETWEEN ECM AND
PRESSURE SENSOR CONNECTOR.
1) Turn ignition switch to OFF and Subaru Select Monitor
or the OBD-II general scan tool switch to OFF.
2) Disconnect connector from pressure sensor.
3) Turn ignition switch to ON and Subaru Select Monitor or
the OBD-II general scan tool switch to ON.
4) Read data on Subaru select monitor or the OBD-II gen-
eral scan tool.
Subaru Select Monitor
Designate mode using function key.
Function mode: F21
: Is the value more than 140 kPa in function
mode F21?
: Repair battery short circuit in harness between
ECM and pressure sensor connector.
: Replace pressure sensor.
OBD-II general scan tool
For detailed operation procedures, refer to the OBD-II Gen-
eral Scan Tool Instruction Manual.
153
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostic Chart with Trouble Code for LHD Vehicles
Page 2006 of 3342

OBD0145A
10H1CONNECT SUBARU SELECT MONITOR
OR THE OBD-II GENERAL SCAN TOOL,
AND READ DATA.
1) Turn ignition switch to OFF.
2) Connect Subaru Select Monitor or the OBD-II general
scan tool to data link connector.
3) Turn ignition switch to ON and Subaru Select Monitor or
OBD-II general scan tool switch to ON.
4) Start engine.
B2M0479
5) Read data on Subaru Select Monitor or OBD-II general
scan tool.
Subaru Select Monitor
Designate mode using function key.
Function mode: F04
F04: Water temperature is indicated in“°C”and“°F”.
: Is the value greater than 150°Cor300°Fin
function mode F04?
: Go to step10H2.
: Repair poor contact.
NOTE:
In this case, repair the following:
Poor contact in engine coolant temperature sensor
Poor contact in ECM
Poor contact in coupling connector (B21)
OBD-II general scan tool
For detailed operation procedures, refer to the OBD-II Gen-
eral Scan Tool Instruction Manual.
OBD0618A
10H2CHECK HARNESS BETWEEN ENGINE
COOLANT TEMPERATURE SENSOR AND
ECM CONNECTOR.
1) Turn ignition switch to OFF.
2) Remove idle air control solenoid valve by-pass air hose.
3) Disconnect connector from engine coolant temperature
sensor.
OBD0145A
4) Connect Subaru Select Monitor or the OBD-II general
scan tool to data link connector.
5) Turn ignition switch and Subaru Select Monitor or
OBD-II general scan tool switch to ON.
155
2-7ON-BOARD DIAGNOSTICS II SYSTEM
10. Diagnostic Chart with Trouble Code for LHD Vehicles