Page 797 of 2389

6. INSPECT RELAY ºCº OPERATION
(a) Apply battery voltage to terminals 5 and 6.
(b) Check that there is continuity between terminals 1
and 3.
If operation is not as specified, replace the relay. 3. INSPECT RELAY ºBº CoNTIN'U1TY
(a) Check that there is continuity between terminals 5
and 8.
(b) Check that there is no continuity between terminals
2 and 3.
If continuity is not as specified, replace the relay.
5. INSPECT RELAY ºCº CONTINUITY
(a) Check that there is continuity between terminals 5
and 6.
(b) Check that there is no continuity between terminals
1 and 3.
If continuity is not as specified, replace the relay. 2. INSPECT RELAY ºAº OPERATION
(a) Apply battery voltage to terminals 5 and 7.
(b) Check that there is continuity between terminals 3
and 4.
If operation is not as specified, replace the relay.
4. INSPECT RELAY ºBº OPERATION
(a) Apply battery voltage to terminals 5 and 8.
(b) Check that there is continuity between terminals 2
and 3.
If operation is not as specified, replace the relay.
± BODY ELECTRICAL SYSTEMHeaterBE±51
Page 798 of 2389

RECIRC/FRESH Control Servo
Motor (Push type)
INSPECTION OF SERVO MOTOR
INSPECT SERVO MOTOR OPERATION
(a) With the positive (+) lead from the battery to terminal
1 and negative (±) lead to terminal 2, check that the
lever moves smoothly from FRESH to RECIRC.
Air Mix Control Servo Motor
(Push Type)
INSPECTION OF SERVO MOTOR
INSPECT SERVO MOTOR OPERATION
(a) With the positive (+) lead from the battery to terminal
8 and negative (±) lead to terminal 2, check that the
lever moves smoothly from WARM to COOL.
The resistance values from COOL to WARM will suc-
cessively decrease.
If operation is not as specified, replace the servo motor.(b) With the positive (+) lead from the battery to terminal
1 and negative (±) lead to terminal 3, check that the
lever moves smoothly from RECIRC to FRESH.
If operation is not as specified, replace the servo motor.
(b) With the positive (+) lead from the battery to terminal
2 and negative (±) lead to terminal 8, check that the
lever moves smoothly from COOL to WARM.
(c) While operating the servo motor from either points
(a) or (b), measure the resistance values of terminals
13 and 15.
Resistance ()
Position
WARM
COOL
± BODY ELECTRICAL SYSTEMHeaterBE±52
Page 799 of 2389
Air Vent Mode Control Servo Motor
(Push Type)
INSPECTION OF SERVO MOTOR
INSPECT SERVO MOTOR OPERATION
(a) Connect the positive (+) lead from the battery to termi-
nal 2 and negative(±) lead to terminal 1, check that the
lever moves smoothly from DEF to FACE.
(b) Connect the positive (+) lead from the battery to ter-
minal 1 and negative (±) lead to terminal 2, check
that the lever moves smoothly from FACE to DEF.
(c) Check for continuity between terminal as shown be-
low.
If operation is not as specified, replace the motor.
Lever position
Foot/DEF
BI±LEVELTerminal
FOOT FACE
DEF
± BODY ELECTRICAL SYSTEMHeaterBE±53
Page 802 of 2389
2. INSPECT MOTOR OPERATION
(a) Connect the positive (+) lead from the battery to ter-
minal 1 and negative (±) lead to terminal 2, check
that the motor turns.
(b) Connect the positive (+) lead from the battery to ter-
minal 2 and negative (±) lead to terminal 1, check
that the motor turns the opposite way.
If operation is not as specified, replace the motor. (b) With the window in the full closed position, hold the
switch in ºDOWNº and check that the window begins
to descend within 60 seconds.
If operation is not as specified, replace the motor.
± BODY ELECTRICAL SYSTEMPower WindowBE±56
Page 805 of 2389

(Door Lock Signal)
HINT: When the relay circuit is as specified, inspect the
door lock signal.
(a) Connect the connector to the relay.
(b) Connect the positive (+) lead from the voltmeter
to terminal 3 and the negative (±) lead to the ter-
minal 4.
(c) Set the door lock manual switch to UNLOCK,
check
that the voltage rises from 0 volts to battery volt-
age for approximately 0.2 seconds.
Door Lock Control Relay
INSPECTION OF RELAY
(Relay Circuit)
Disconnect the connector from the relay and inspect the
connector on the wire harness side as shown in the chart.
If circuit is as specified, inspect the door lock signal.
OFF or lock
(Door key free or turned to lock)
Passenger's door courtesy
switch positionPassenger's ±door lock
switch positionDriver's door courtesty
switch position
Unlock (Door key turned to unlock) Door key lock and unlock
switch position Key unlock warning
switch positionOFF (Ignition key removed)
Door lock manual
switch position
Door lock manual
switch positionDriver's door lock
switch position
Ignition switch
positionON (ignition key set) ON (Door unlocked)
ON (Door unlocked) ON (Door opened)
Tester connection
OFF (Door locked)
ON (Door opened)OFF (Door locked)
OFF (Door closed)OFF (Door closed)Specified value
No continuity
Battery voltage Battery voltage OFF or UnlockNo continuity
No continuityNo continuity
No continuity
No continuity
No continuityNo continuity
Continuity OFF or Lock
No voltageContinuityContinuity
Continuity ContinuityContinuity
ContinuityContinuityContinuity
ACC or ON Continuity
ConditionCheck for
ConstantConstant
VoltageUnlock
LOCKLock
± BODY ELECTRICAL SYSTEMDoor Lock Control SystemBE±59
Page 806 of 2389

Door Lock Solenoid
INSPECTION OF DOOR LOCK
SOLENOID
1. INSPECT SOLENOID OPERATION
(Front and Rear door)
(a) Connect the positive (+) lead from the battery to
terminal 4 and negative(±) lead to terminal 3, check
that the solenoid operation in the lock (Pull) direction.
(b) Check that there is no continuity between terminals
1 and 2.
(c) Connect the positive (+) lead from the battery to termi-
nal 3 and negative (±) lead to terminal 4, check that
the solenoid operation in the unlock (Push) direction.
(d) Check that there is continuity between terminals 1
and 2.
If operation is not as specified, replace the solenoid.
(c) Connect the positive (+) lead from the battery to ter-
minal 4 and negative (±) lead to terminal 2, check that
the solenoid operation in the unlock (Push) direction.
(d) Check that there is continuity between terminals 1
and 3.
If operation is not as specified, replace the solenoid. (Back door)
(a) Connect the positive (+) lead from the battery to
terminal 2 and negative (±) lead to terminal 4, check
that the solenoid operation in the lock (Pull) direction.
(b) Check that there is no continuity between terminals
1 and 3. (d) Reverse the polarity of the voltmeter leads.
(e) Set the door lock manual switch to LOCK, check that
the voltage rises from 0 volts to battery voltage for
approximately 0.2 seconds.
If operation is not as specified, replace the relay.
± BODY ELECTRICAL SYSTEMDoor Lock Control SystemBE±60
Page 807 of 2389

Moon Roof Motor
INSPECTION OF MOTOR
INSPECT MOTOR OPERATION
(a) Connect the positive (+) lead from the battery to term
inall andnegative(±)lead toterminal2,check that
the motor turns.
(b) Connect the positive (+) lead from the battery to
terminal 2 and negative (±) lead to terminal 1, check
that the motor turns the opposite way.
If operation is not as specified, replace the motor.
Moon Roof Control Relay
INSPECTION OF RELAY
INSPECT RELAY VOLTAGE AND CONTINUITY
(a) Disconnect the relay connector and inspect the con-
nector on the wire harness side as shown in the
chart.
Limit Switch
INSPECTION OF SWITCH
INSPECT SWITCH CONTINUITY
(a) Check that there is continuity between terminals 1
and 4 when the switch is ON.
(b) Check that there is no continuity between terminals
1 and 4 when the switch is OFF.
If continuity is not as specified, replace the switch.
MOON ROOF
Moon Roof Switch
INSPECTION OF SWITCH
INSPECT SWITCH CONTINUITY
Inspect the switch continuity between terminals.
If continuity is not as specified, replace the
switch.
Switch positionTerminal
CLOSEOPEN
± BODY ELECTRICAL SYSTEMMoon RoofBE±61
Page 808 of 2389
(b) Connect the positive lead from the battery to termi-
nal 1 and±negative (±y lead to terminal 5, check that
the motor turns to close. Then, reverse the polarity,
check that the motor turns to open. 1f motor does not
operate, remove and test the motor.
If circuit operation is correct, replace the relay.
Push sun roof switch to except CLOSE
Push sun roof switch to except OPEN Push sun roof switch to CLOSE
Push sun roof switch to OPEN Turn ignition switch OFFTurn ignition switch ON
Push limit switch ON
Push limit switch OFFSpecified value Tester
connection
10 ± Body ground
12 ± Body ground8 ± Body ground 4 ± Body ground
6 ± Body ground
7 ± Body groundBattery voltage
No continuity
No continuity No continuity
Continuity Continuity
Continuity
Continuity Continuity
Continuity No.voitage
Continuity Continuity
Continuity Continuity
ConditionCheck for
Voltage
± BODY ELECTRICAL SYSTEMMoon RoofBE±62