TOYOTA SIENNA 2007  Service Repair Manual U151E AUTOMATIC TRANSAXLE  –  AUTOMATIC TRANSAXLE SYSTEMAX–115
AX
TYPICAL MALFUNCTION THRESHOLDS
P0985: Range check (Low resistance):
P0986: Range check (High resistance):
COMPONENT OPERATING RANG

Page 1482 of 3000

TOYOTA SIENNA 2007  Service Repair Manual AX–116U151E AUTOMATIC TRANSAXLE  –  AUTOMATIC TRANSAXLE SYSTEM
AX
(a) Connect the transmission wire connector to the 
transaxle.
(b) Disconnect the connector from the ECM.
(c) Measure the resistan

Page 1483 of 3000

TOYOTA SIENNA 2007  Service Repair Manual U151E AUTOMATIC TRANSAXLE  –  AUTOMATIC TRANSAXLE SYSTEMAX–117
AX
SYSTEM DESCRIPTION
The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation 
base

Page 1484 of 3000

TOYOTA SIENNA 2007  Service Repair Manual AX–118U151E AUTOMATIC TRANSAXLE  –  AUTOMATIC TRANSAXLE SYSTEM
AX
MONITOR DESCRIPTION
In any forward position, when the difference between the revolutions of the turbine, Intermediate and 
output

Page 1487 of 3000

TOYOTA SIENNA 2007  Service Repair Manual U151E AUTOMATIC TRANSAXLE  –  AUTOMATIC TRANSAXLE SYSTEMAX–121
AX
Result
HINT:
If any other codes besides "P2714" are output, perform the 
troubleshooting for those DTCs first.
B
A
(a) Rem

Page 1489 of 3000

TOYOTA SIENNA 2007  Service Repair Manual U151E AUTOMATIC TRANSAXLE  –  AUTOMATIC TRANSAXLE SYSTEMAX–123
AX
DESCRIPTION
The linear solenoid valve (SLT) controls the transmission line pressure for smooth transmission operation 
based on si

Page 1491 of 3000

TOYOTA SIENNA 2007  Service Repair Manual U151E AUTOMATIC TRANSAXLE  –  AUTOMATIC TRANSAXLE SYSTEMAX–125
AX
INSPECTION PROCEDURE
(a) Disconnect the transmission wire connector from the 
transaxle.
(b) Measure the resistance according to t

Page 1492 of 3000

TOYOTA SIENNA 2007  Service Repair Manual AX–126U151E AUTOMATIC TRANSAXLE  –  AUTOMATIC TRANSAXLE SYSTEM
AX
(a) Remove the shift solenoid valve (SLT).
(b) Measure the resistance according to the value(s) in the 
table below.
Standard resi