2006 DODGE RAM SRT-10 oil

[x] Cancel search: oil

Page 1333 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.(K342) ASD CONTROL OUTPUT CIRCUIT SHORTED TO GROUND
Turn the ignition off
Disconnect the C10 TIPM harness connector.
Measure resistance between ground and (K342) ASD Control Output
circuit at the C1

Page 1336 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10 volts.
Set Condition:
A shorted condition is detected in the ASD control circuit. One Trip Fault.Three good trips to turn off the

Page 1337 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.(K342) ASD CONTROL OUTPUT CIRCUIT SHORTED TO VOLTAGE
Turn the ignition off
Disconnect the C10 TIPM harness connector.
Measure the voltage on the (K342) ASD Control Output circuit at the
C10 TIPM har

Page 1340 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10 volts.
Set Condition:
An open condition is detected in the ASD control circuit. One Trip Fault. Three good trips to turn off the M

Page 1341 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.(K342) ASD CONTROL OUTPUT CIRCUIT
Turn the ignition off
Connect the C2 TIPM harness connector.
Ignition on, engine not running.
Back probe the C10 TIPM harness connector at the (K342) ASD Control Ou

Page 1344 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual When Monitored:
With the ignition on. Battery voltage greater than 10 volts.
Set Condition:
An overcurrent condition is detected in the ASD control circuit. One Trip Fault. Three good trips to turn of

Page 1345 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 3.(K342) ASD CONTROL OUTPUT CIRCUIT
Turn the ignition off
Connect the C2 TIPM harness connector.
Ignition on, engine not running.
Back probe the C10 TIPM harness connector at the (K342) ASD Control Ou

Page 1346 of 5267

DODGE RAM SRT-10 2006  Service Repair Manual 6.PCM Turn the ignition off.
Disconnect C3 NGC harness connector.
CAUTION: Do not probe the PCM harness connectors. Probing the PCM harness connectors will damage
the PCM terminals resulting in poor t