Page 5220 of 5267
If Equipped With Vertically Mounted EVAP Canisters
The NVLD pump (4) is located at the front of fuel tank.
1. Snap NVLD pump (1) to EVAP canister until tab (2)
engages.
2. Connect electrical connector to NVLD pump.
3. Carefully install vapor/vacuum lines to NVLD pump.
The vapor/vacuum lines and hoses must be
firmly connected. Check the vapor/vacuum
lines at the NVLD pump, filter and EVAP canis-
ter purge solenoid for damage or leaks. If a leak
is present, a Diagnostic Trouble Code (DTC)
may be set.
4. If equipped, install skid plate(s).
Page 5235 of 5267
3. Remove fuel tubes/lines (1) at each EVAP canister.
Note location of tubes/lines before removal for eas-
ier installation. Remove bolts (6).
4. Remove nut (1) and remove NVLD filter (2).
Page 5241 of 5267
3. Install NVLD filter (2) and nut (1).
4. Carefully install vapor/vacuum lines, and fuel tubes/
lines (1) to each EVAP canister. Install bolts (6).
5.The vapor/vacuum lines and hoses must be
firmly connected. Also check the vapor/vacuum
lines at the NVLD Pump, LDP, LDP filter and
EVAP canister purge solenoid for damage or
leaks. If a leak is present, a Diagnostic Trouble
Code (DTC) may be set.
6. If necessary, install skid plate(s).