Page 272 of 4500
WIRING DIAGRAM
Fig. 55: Air Duct Sensor Circuit (Driver Side)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
INSPECTION PROCEDURE
1.READ VALUE ON HAND-HELD TESTER
a. Connect the hand-held tester to the DLC3.
b. Turn the ignition switch to the ON position and push the hand-held tester main switch on.
c. Select the item below in the DATA LIST, and read the display on the hand-held tester.
DATA LIST / AIR CONDITIONER:
DATA LIST / AIR CONDITIONER
OK:
The display is as specified in the normal condition.
Result:
AIR CONDITIONER TEST RESULT
ItemMeasure Item/Display (Range)Normal ConditionDiagnostic
Note
DUCT
TEMP-DDuct sensor (Driver side) / min.: -12.7°C
(9.14°F) max.: 76.55°C (169.79°F)Actual duct temperature is
displayed (Driver side)-
Page 274 of 4500
Fig. 56: Inspecting Air Conditioning Amplifier (TFACEDR - SG-3)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
Result:
AIR CONDITIONING AMPLIFIER (TFACEDR - SG-3) TEST RESULT
B: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
C: REPLACE AIR CONDITIONING AMPLIFIER (SEE REPLACEMENT )
A: Go to next step
3.INSPECT AIR DUCT SENSOR
a. Remove the air duct sensor.
b. Measure the resistance according to the value (s) in the table below.
Standard:
NGA
OK (Checking from the PROBLEM SYMPTOM TABLE)B
OK (Checking from the DTC)C
Page 275 of 4500
AIR DUCT SENSOR RESISTANCE
HINT:
As the temperature increases, the resistance decreases.
Fig. 57: Inspecting Air Duct Sensor
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
NG: REPLACE AIR DUCT SENSOR
OK: Go to next step
4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT
SENSOR) (SEE ELECTRONIC CIRCUIT INSPECTION PROCEDURE
)
a. Measure the resistance according to the value (s) in the table below.
Tester connectionConditionSpecified condition
D7-1 - D7-2at 0°C (32°F)14.5 to 19.0 kohms
D7-1 - D7-2at 25°C (77°F)4.8 to 5.2 kohms
D7-1 - D7-2at 50°C (122°F)1.6 to 2.0 kohms
Page 276 of 4500
Standard:
AIR CONDITIONING AMPLIFIER - AIR DUCT SENSOR RESISTANCE
Tester connectionConditionSpecified condition
A13-15 (TFACEDr) - D7-1AlwaysBelow 1 ohms
A13-10 (SG-3) - D7-2AlwaysBelow 1 ohms
A13-15 (TFACEDr) - Body groundAlways10 kohms or higher
A13-10 (SG-3) - Body groundAlways10 kohms or higher
Page 277 of 4500
Fig. 58: Checking Harness And Connector (Air Conditioning Amplifier - Air Duct Sensor)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
Page 278 of 4500
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE AIR CONDITIONING AMPLIFIER (SEE REPLACEMENT )
CIRCUIT DESCRIPTION
This sensor detects the register temperature and sends the appropriate signals to the A/C amplifier.
Fig. 59: DTC Detection Item Trouble Area Chart
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
WIRING DIAGRAM
Fig. 60: Air Duct Sensor Circuit (Passenger Side)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
INSPECTION PROCEDURE
1.READ VALUE ON HAND-HELD TESTER
Page 279 of 4500

a. Connect the hand-held tester to the DLC3.
b. Turn the ignition switch to the ON position and push the hand-held tester main switch on.
c. Select the item below in the DATA LIST, and read the display on the hand-held tester.
DATA LIST / AIR CONDITIONER:
DATA LIST / AIR CONDITIONER
OK:
The display is as specified in the normal condition.
Result:
AIR CONDITIONER TEST RESULT
B: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
C: REPLACE AIR CONDITIONING AMPLIFIER (SEE REPLACEMENT )
A: Go to next step
2.INSPECT AIR CONDITIONING AMPLIFIER (TFACEPa - SG-4)
a. Remove the A/C amplifier with connectors still connected.
b. Turn the ignition switch to the ON position.
c. Measure the voltage according to the value (s) in the table below.
Standard:
AIR CONDITIONING AMPLIFIER (TFACEPa - SG-4) VOLTAGE
HINT:
As the temperature increases, the volta
ge decreases.
ItemMeasure Item/Display (Range)Normal ConditionDiagnostic
Note
DUST
TEMP-PDuct sensor (Passenger side) / min.: -12.7°C
(9.14°F) max.: 76.55°C (169.79°F)Actual duct temperature is
displayed (Passenger side)-
NGA
OK (Checking from the PROBLEM SYMPTOM TABLE)B
OK (Checking from the DTC)C
Tester connectionConditionSpecified condition
A13-14 (TFACEPa) - A13-11 (SG-4)Ignition switch ON at 25°C (77°F)1.8 to 2.2 V
A13-14 (TFACEPa) - A13-11 (SG-4)Ignition switch ON at 50°C (122°F)0.8 to 1.2 V
Page 280 of 4500
Fig. 61: Inspecting Air Conditioning Amplifier (TFACEPA - SG-4)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
Result:
AIR CONDITIONING AMPLIFIER (TFACEPA - SG-4) TEST RESULT
B: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
C: REPLACE AIR CONDITIONING AMPLIFIER (SEE REPLACEMENT )
A: Go to next step
3.INSPECT AIR DUCT SENSOR
a. Remove the air duct sensor.
b. Measure the resistance according to the value (s) in the table below.
Standard:
NGA
OK (Checking from the PROBLEM SYMPTOM TABLE)B
OK (Checking from the DTC)C