Tool Hole
Terminal LanceSpecial
Tool
Special
Tool
Tool HoleSpecial Tool
Terminal
Lance Special Tool 0.64 Type
B±25
TERMINAL AND CONNECTOR REPAIR±TERMINAL REPLACEMENT
35
Wire Harness Repair Manual (RM1022E)
Insulation Displacement Connector Type
(a)Using a special tool, push the terminal lance from the
tool hole.
(b)Carefully withdraw the terminal from the connector by
pulling the lead toward the rear of the connector.
NOTICE:
Do not use too much force. If the terminal does not
come out easily, repeat step (a).
Always change the wire with the repair wire, in
accordance with page B±27.
F±17
TABLE OF REPAIR WIRE, TERMINAL PACKING, HOLE PLUG AND PRESS SLEEVE
Wire Harness Repair Manual (RM1022E)
395
Repair Wire (Non±waterproof Type)
TypeSP
Female (Power)Female (Signal)
Sleeve : Medium (Blue) or Large (Yellow)Sleeve : Medium (Blue) or Large (Yellow)
P/N82998±1252082998±12530
TypeTLC
MaleFemale
Sleeve : Medium (Blue)Sleeve : Medium (Blue)
P/N82998±1222082998±12230
TypeTNS
MaleFemale
Sleeve : Medium (Blue)Sleeve : Medium (Blue)
P/N82998±1224082998±12250