EC-444
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
ELECTRICAL LOAD SIGNAL
ELECTRICAL LOAD SIGNAL
DescriptionINFOID:0000000012431645
The electrical load signal (Headlamp switch signal, rear window defogger switch signal, etc.) is transferred to
ECM through the CAN communication line.
Component Function CheckINFOID:0000000012431646
1.CHECK REAR WINDOW DEFOGGER SWITCH FUNCTION
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT.
3. Select “LOAD SIGNAL” and check indication under the following conditions.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Go to EC-444, "
Diagnosis Procedure".
2.CHECK LIGHTING SWITCH FUNCTION
Check “LOAD SIGNAL” indication under the following conditions.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Go to EC-444, "
Diagnosis Procedure".
3.CHECK HEATER FAN CONTROL SWITCH FUNCTION
Select “HEATER FAN SW” and check indication under the following conditions.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC-444, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000012431647
1.INSPECTION START
Confirm the malfunctioning circuit (rear window defogger, headlamp or heater fan). Refer to EC-444, "
Compo-
nent Function Check".
Which circuit is related to the incident?
Rear window defogger>>GO TO 2
Headlamp>>GO TO 3.
Heater fan>>GO TO 4.
2.CHECK REAR WINDOW DEFOGGER SYSTEM
Perform trouble diagnosis of rear window defogger system. Refer to DEF-17, "
Work Flow".
Monitor itemConditionIndication
LOAD SIGNAL Rear window defogger switch ON ON
OFF OFF
Monitor item
ConditionIndication
LOAD SIGNAL Lighting switch ON at 2nd position ON
OFF
OFF
Monitor item ConditionIndication
HEATER FAN SW Heater fan control switch ON ON
OFF OFF
Revision: August 2015
2016 Versa Note
cardiagn.com
FUEL INJECTOREC-447
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
• 10 A fuse (No. 55)
• Harness for open or short between fuel injector and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK FUEL INJECTOR OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between fuel injector harness connector and ECM harness connector.
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK FUEL INJECTOR
Refer to EC-447, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Replace malfunctioning fuel injector. Refer to EM-40, "
Removal and Installation"
5.CHECK INTERMITTENT INCIDENT
Refer to GI-42, "
Intermittent Incident".
Is the inspection result normal?
YES >> Replace IPDM E/R. Refer to PCS-30, "Removal and Installation".
NO >> Repair or replace harness or connectors.
Component InspectionINFOID:0000000012431650
1.CHECK FUEL INJECTOR
1. Turn ignition switch OFF.
2. Disconnect fuel injector harness connector.
3. Check resistance between fuel injector terminals as follows.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace malfunctioning fuel injector. Refer to EM-40, "
Removal and Installation".
Fuel injectorECM
Continuity
Cylinder Connector Front / Rear Terminal Connector Terminal
1 F17 Front
2
F10 31
Existed
F53 Rear
12
2 F18 Front
230
F54 Rear 20
3 F19 Front
229
F29 Rear 16
4 F20 Front
225
F30 Rear 24
TerminalsResistance
1 and 2 11.1 - 14.5 Ω [at 10 - 60°C (50 - 140 °F)]
Revision: August 2015 2016 Versa Note
cardiagn.com
IGNITION SIGNALEC-451
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
IGNITION SIGNAL
Component Function CheckINFOID:0000000012431654
1.INSPECTION START
Turn ignition switch OFF, and restart engine.
Does the engine start?
YES-1 >> With CONSULT: GO TO 2.
YES-2 >> Without CONSULT: GO TO 3.
NO >> Go to EC-451, "
Diagnosis Procedure".
2.IGNITION SIGNAL FUNCTION
With CONSULT
1. Perform “POWER BALANCE” in “ACTIVE TEST” mode with CONSULT.
2. Make sure that each circuit produces a momentary engine speed drop.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC-451, "
Diagnosis Procedure".
3.IGNITION SIGNAL FUNCTION
Without CONSULT
1. Let engine idle.
2. Check the voltage signal between ECM harness connector and ground with an oscilloscope.
NOTE:
The pulse cycle changes depending on rpm at idle.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC-451, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000012431655
1.CHECK IGNITION COIL POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
2. Check the voltage between ECM harness connector and ground.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Go to EC-159, "
Diagnosis Procedure".
ECM
Voltage signal
+ −
Connector Terminal Connector Terminal
F7 17
E16 108
18
21
22
JMBIA0219GB
ECM
Vo l ta g e
Connector Te r m i n a l
+ −
E16 105108 Battery voltage
Revision: August 2015 2016 Versa Note
cardiagn.com
EC-452
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
IGNITION SIGNAL
2.CHECK IGNITION COIL POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect condenser harness connector.
3. Turn ignition switch ON.
4. Check the voltage between condenser harness connector and ground.
Is the inspection result normal?
YES >> GO TO 5.
NO >> GO TO 3.
3.CHECK IGNITION COIL POWER SUPPLY CIRCUIT-III
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R harness connector F42.
3. Check the continuity between IPDM E/R harness connector and condenser harness connector.
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 11.
NO >> GO TO 4.
4.DETECT MALFUNCTIONING PART
Check the following.
• Harness for open or short between IPDM E/R and condenser
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK CONDENSER GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check the continuity between condenser harness connector and ground.
3. Also check harness for short to power.
Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
6.CHECK CONDENSER
Refer to EC-455, "
Component Inspection (Condenser)"
Is the inspection result normal?
YES >> GO TO 7.
NO >> Replace condenser.
7.CHECK IGNITION COIL POWER SUPPLY CIRCUIT-IV
1. Reconnect all harness connectors disconnected.
2. Disconnect ignition coil harness connector.
Condenser Ground Voltage
Connector Terminal
F26 1Ground Battery voltage
IPDM E/R Condenser
Continuity
Connector Terminal Connector Terminal
F423 4F 26 1E xis te d
Condenser
Ground Continuity
Connector Terminal
F26 2Ground Existed
Revision: August 2015 2016 Versa Note
cardiagn.com
IGNITION SIGNALEC-453
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
3. Turn ignition switch ON.
4. Check the voltage between ignition coil harness connector and ground.
Is the inspection result normal?
YES >> GO TO 8.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
8.CHECK IGNITION COIL GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check the continuity between ignition coil harness connector and ground.
3. Also check harness for short to power.
Is the inspection result normal?
YES >> GO TO 9.
NO >> Repair open circuit or short to power in harness or connectors.
9.CHECK IGNITION COIL OUTPUT SI GNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check the continuity between ECM harness connector and ignition coil harness connector.
3. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 10.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
10.CHECK IGNITION COIL WITH POWER TRANSISTOR
Refer to EC-454, "
Component Inspection (Ignition Coil with Power Transistor)".
Is the inspection result normal?
YES >> GO TO 11.
NO >> Replace malfunctioning ignition coil with power transistor. Refer to EM-47, "
Removal and Installa-
tion".
11 .CHECK INTERMITTENT INCIDENT
Refer to GI-42, "
Intermittent Incident".
Ignition coil
Ground Voltage
Cylinder Connector Terminal
1F343
Ground Battery voltage
2F353
3F363
4F373
Ignition coil
Ground Continuity
Cylinder Connector Terminal
1F342
GroundExisted
2F352
3F362
4F372
Ignition coil
ECM
Continuity
Cylinder Connector Terminal Connector Terminal
1F341
F1017
Existed
2F351
18
3F361 22
4F371 21
Revision: August 2015 2016 Versa Note
cardiagn.com
EC-454
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
IGNITION SIGNAL
>> INSPECTION END
Component Inspection (Ignition Coil with Power Transistor)INFOID:0000000012431656
1.CHECK IGNITION COIL WITH POWER TRANSISTOR-I
1. Turn ignition switch OFF.
2. Disconnect ignition coil harness connector.
3. Check resistance between ignition coil terminals as follows.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Replace malfunctioning ignition coil with power transistor. Refer to EM-47, "
Removal and Installa-
tion".
2.CHECK IGNITION COIL WITH POWER TRANSISTOR-II
CAUTION:
Do the following procedure in the place where ventilation is good without the combustible.
1. Turn ignition switch OFF.
2. Reconnect all harness connectors disconnected.
3. Remove fuel pump fuse in IPDM E/R to release fuel pressure. NOTE:
Do not use CONSULT to release fuel pressure, or fuel pressure applies again during the following proce-
dure.
4. Start engine.
5. After engine stalls, crank it two or three times to release all fuel pressure.
6. Turn ignition switch OFF.
7. Remove all ignition coil harness connectors to avoi d the electrical discharge from the ignition coils.
8. Remove ignition coil and spark plug of the cylinder to be checked.
9. Crank engine for 5 seconds or more to remove combustion gas in the cylinder.
10. Connect spark plug and harness connector to ignition coil.
11. Fix ignition coil using a rope etc. with gap of 13 - 17 mm (0.52 -
0.66 in) between the edge of the spark plug and grounded metal
portion as shown in the figure.
12. Crank engine for about three seconds, and check whether spark
is generated between the spark plug and the grounded metal
portion.
CAUTION:
• Do not approach to the spar k plug and the ignition coil
within 50 cm (19.7 in). Be careful not to get an electrical
shock while checking, because the electrical discharge
voltage becomes 20 kV or more.
• It might cause to damage the igni tion coil if the gap of more than 17 mm (0.66 in) is taken.
NOTE:
When the gap is less than 13 mm (0.52 in), the sp ark might be generated even if the coil is mal-
functioning.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace malfunctioning ignition coil with power transistor. Refer to EM-47, "
Removal and Installa-
tion".
TerminalsResistance
1 and 2 Except 0 or ∞ Ω [at 25 °C (77 °F)]
1 and 3 Except 0 Ω [at 25 °C (77 °F)]
2 and 3
Spark should be generated.
JMBIA0066GB
Revision: August 2015 2016 Versa Note
cardiagn.com
IGNITION SIGNALEC-455
< DTC/CIRCUIT DIAGNOSIS > [HR16DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Component Inspection (Condenser)INFOID:0000000012431657
1.CHECK CONDENSER
1. Turn ignition switch OFF.
2. Disconnect condenser harness connector.
3. Check resistance between condenser terminals as follows.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace condenser.
Terminals Resistance [at 25 °C (77 °F)]
1 and 2 Above 1 MΩ
Revision: August 2015 2016 Versa Note
cardiagn.com
EC-462
< DTC/CIRCUIT DIAGNOSIS >[HR16DE]
REFRIGERANT PRESSURE SENSOR
REFRIGERANT PRESSURE SENSOR
Component Function CheckINFOID:0000000012431664
1.CHECK REFRIGERANT PRESSURE SENSOR OVERALL FUNCTION
1. Start engine and warm it up to normal operating temperature.
2. Turn A/C switch and blower fan switch ON.
3. Check the voltage between ECM harness connector and ground.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC-462, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000012431665
1.CHECK GROUND CONNECTION
1. Turn A/C switch and blower fan switch OFF.
2. Stop engine.
3. Turn ignition switch OFF.
4. Check ground connection E15. Refer to Ground Inspection in GI-44, "
Circuit Inspection".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace ground connection.
2.CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Disconnect refrigerant pressure sensor harness connector.
2. Turn ignition switch ON.
3. Check the voltage between refrigerant pressure sensor harness connector and ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> GO TO 3.
3.DETECT MALFUNCTIONING PART
Check the following.
• Harness for open or short between ECM and refrigerant pressure sensor
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between refrigerant pre ssure sensor harness connector and ECM harness connec-
tor.
ECM
Vol tag e
Connector Te r m i n a l
+ −
E16 101
(Refrigerant pressure sensor signal) 98 1.0 - 4.0V
Refrigerant pressure sensor
Ground Voltage
Connector Terminal
E17 3Ground Approx. 5 V
Revision: August 2015 2016 Versa Note
cardiagn.com