SWS -Troubleshooting54B-35
Terminal
No.Normal condition Checking requirements Check items
35Driver’s door lock actuator (locking
switch) inputWhen driver’s door lock locked0V
36Driver’s door lock actuator (unlocking
switch) inputWhen driver’s door lock unlocked0V
37, 38---
39Back-up lamp switch inputWhen shift lever in reverse positionSystem voltage
40---
51Diagnosis output/input check signal
outputDuring diagnosis output (when MUT-II
connected or diagnosis connector No. 1
grounded on the body.)0 - 12 V (pulse
signal)
When an input check is output0, 12 V (at input
signal change)
52Ignition switch (ACC) power supplyIgnition switch: ACCSystem voltage
53, 54---
55Hazard warning lamp switch inputHazard warning lamp switch: ON0V
56Earth (for sensors)Any time0V
57, 58---
59SWS communication lineAny time0 - 12 V (pulse
signal)
60---
61Battery power supplyAny timeSystem voltage
62---
63Vehicle speed signal inputWhen vehicle driven0 - 12 V (pulse
signal)
64 - 66---
67Diagnosis control inputWhen MUT-II connected0V
68SWS request signal outputAny time0 - 12 V (pulse
signal)
69Ignition key cylinder illumination lamp
outputWhen ignition key cylinder illumination
lamp ON2 V or below
70---
71 - 73---
74Rear fog lamp output
General Export-spec. models>When rear fog lamps ONSystem voltage