2007 INFINITI QX56 DTC

[x] Cancel search: DTC

Page 1445 of 3061

INFINITI QX56 2007  Factory Service Manual EC-362
< SERVICE INFORMATION >
DTC P0442 EVAP CONTROL SYSTEM
6.CHECK FOR EVAP LEAK
 With CONSULT-II
1. Turn ignition switch ON.
2. Select “EVAP SYSTEM CLOSE” of “WORK SUPPORT” mode with CONSUL

Page 1446 of 3061

INFINITI QX56 2007  Factory Service Manual DTC P0442 EVAP CONTROL SYSTEM
EC-363
< SERVICE INFORMATION >
C
D
E
F
G
H
I
J
K
L
MA
EC
N
P O
4. Using EVAP leak detector, locate the EVAP leak. For the leak
detector, refer to the instruction manual f

Page 1447 of 3061

INFINITI QX56 2007  Factory Service Manual EC-364
< SERVICE INFORMATION >
DTC P0442 EVAP CONTROL SYSTEM
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-II screen to increase “PURG VOL
CONT/V” openin

Page 1448 of 3061

INFINITI QX56 2007  Factory Service Manual DTC P0442 EVAP CONTROL SYSTEM
EC-365
< SERVICE INFORMATION >
C
D
E
F
G
H
I
J
K
L
MA
EC
N
P O
Clean EVAP purge line (pipe and rubber tube) using air blower.
>> GO TO 20.
20.CHECK EVAP/ORVR LINE
Check E

Page 1449 of 3061

INFINITI QX56 2007  Factory Service Manual EC-366
< SERVICE INFORMATION >
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VA LV E
DescriptionINFOID:0000000003531859
SYSTEM DESCR

Page 1450 of 3061

INFINITI QX56 2007  Factory Service Manual DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-367
< SERVICE INFORMATION >
C
D
E
F
G
H
I
J
K
L
MA
EC
N
P O
On Board Diagnosis LogicINFOID:0000000003531861
DTC Confirmation ProcedureINF

Page 1451 of 3061

INFINITI QX56 2007  Factory Service Manual EC-368
< SERVICE INFORMATION >
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Wiring Diagram
INFOID:0000000003531863
Specification data are reference values and are measured between each

Page 1452 of 3061

INFINITI QX56 2007  Factory Service Manual DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-369
< SERVICE INFORMATION >
C
D
E
F
G
H
I
J
K
L
MA
EC
N
P O
Do not use ECM ground terminals when measuring input/output voltage. Doing so