2006 MERCEDES-BENZ SPRINTER ABS

[x] Cancel search: ABS

Page 384 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
SOLENOID RELAY
When Monitored and Set Condition:
SOLENOID RELAY
When Monitored: Ignition On - Continuously.
Set Condition: When there is a voltage deviation from the expected result of a CAB

Page 385 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
3 Turn the ignition off.
Disconnect the CAB harness connector.
Turn the ignition on.
Using a 12-volt test light connected to ground, check the Fused Optional Equipment
Relay

Page 396 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
SYSTEM OVERVOLTAGE
POSSIBLE CAUSES
INTERMITTENT DTC
DAMAGED CAB/CAB HARNESS CONNECTOR
GROUND CIRCUIT OPEN
ANTI-LOCK BRAKE CONTROLLER
TEST ACTION APPLICABILITY
1NOTE: Repair any Powertrain cha

Page 397 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
4 Turn the ignition off.
Visually inspect the related wiring harness.
Look for any chafed, pierced, pinched, or partially broken wires.
Look for broken, bent, pushed out, or

Page 398 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
SYSTEM UNDERVOLTAGE
POSSIBLE CAUSES
INTERMITTENT DTC
DAMAGED CAB/CAB HARNESS CONNECTOR
FUSED OPTIONAL EQUIPMENT RELAY OUTPUT CIRCUIT HIGH RESISTANCE
FUSED B(+) CIRCUIT HIGH RESISTANCE
GROUND

Page 399 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
4 Turn the ignition off.
Disconnect the CAB harness connector.
Using a 12-volt test light connected to ground, check both Fused B(+) circuits at the
CAB harness connector.
NO

Page 400 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Verification Tests
ABS VERIFICATION TEST - VER 1 APPLICABILITY
1. Turn the ignition off.
2. Connect all previously disconnected components and connectors.
3. Ensure all accessories are turned off and

Page 405 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual CONTROLLER ANTILOCK BRAKECAV CIRCUIT FUNCTION
1 12BR GROUND
2 12RD FUSED B(+)
3- -
4- -
5 14BR GROUND
6 14RD FUSED B(+)
7- -
8 20BK/DG SENSOR SIGNAL
9 20YL/WT SENSOR SIGNAL
10 20YL/RD SENSOR SIGNAL
11