2006 MERCEDES-BENZ SPRINTER lock

[x] Cancel search: lock

Page 214 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
RKE INTERFACE CIRCUIT SHORT TO GROUND - CTM
When Monitored and Set Condition:
RKE INTERFACE CIRCUIT SHORT TO GROUND - CTM
When Monitored: Whenever the battery voltage is above 10.0 volts and

Page 215 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
3 Disconnect the Central Timer Module C1 connector.
Disconnect the SKREEM connector.
Measure the resistance between ground and the RKE Interface circuit.
Is the resistance be

Page 216 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
RKE INTERFACE CIRCUIT SHORT TO GROUND - SKREEM
When Monitored and Set Condition:
RKE INTERFACE CIRCUIT SHORT TO GROUND - SKREEM
When Monitored: Whenever the battery voltage is above 10.0 volt

Page 217 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
3 Disconnect the Central Timer Module C1 connector.
Disconnect the SKREEM connector.
Measure the resistance between ground and the RKE Interface circuit.
Is the resistance be

Page 218 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
RKE INTERFACE CIRCUIT SHORT TO VOLTAGE - CTM
When Monitored and Set Condition:
RKE INTERFACE CIRCUIT SHORT TO VOLTAGE - CTM
When Monitored: Whenever the battery voltage is above 10.0 volts an

Page 219 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
RKE INTERFACE CIRCUIT SHORT TO VOLTAGE - SKREEM
When Monitored and Set Condition:
RKE INTERFACE CIRCUIT SHORT TO VOLTAGE - SKREEM
When Monitored: Whenever the battery voltage is above 10.0 vo

Page 220 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual TEST ACTION APPLICABILITY
3 Disconnect the Central Timer Module C1 connector.
Disconnect the SKREEM connector.
Turn the ignition on.
Measure the voltage between ground and the RKE Interface circuit.
I

Page 221 of 2305

MERCEDES-BENZ SPRINTER 2006  Service Manual Symptom:
THE ACM HAS UNLOCKED THE DOORS
When Monitored and Set Condition:
THE ACM HAS UNLOCKED THE DOORS
When Monitored: Whenever the battery is above 10.0 volts and the module is connected.
Set Condi