I36146
Display code R/FDEFLHD:
I36147
Display code RHD:R/FDEF
Blower level Step No.Display
codeConditions
Air flow bent Air inlet damper Compressor
ºCOOLº side (Full closed)Air mix damper
OFF FRESH
FACE 0
1
2
3
6
7
8
9
104
51
16
16
16
16
16
16
16
31 0
1
2
3
6
7
8 4
5
9FACE
FACE
FACE
B/L
FOOT1
FOOT/ DEF.
DEF.FRESH
ON
ON
ON
ON
ON
ON
ONºCOOLº side (Full closed)
ºCOOLº side (Full closed)
ºCOOLº side (Full closed)
ºCOOLº/ ºHOT º (50 % open)
ºHOTº side (Full opened)
FOOT FACE1FRESH
FRESH
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATIONHot gas magnetic valve
ºCOOLº/ ºHOT º (50 % open)
ºHOTº side (Full opened)
ºHOTº side (Full opened)ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF OFF
ºHOTº side (Full opened) OFF
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1093
AVENSIS REPAIR MANUAL (RM1018E)
6. ACTUATOR CHECK
(a) After entering the DTC check mode (Sensor Check
Mode) press the R/F switch.
(b) Since each damper, motor and relay automatically oper-
ates at 1 second intervals beginning in order from 10 in
the temperature display, check the temperature and air
flow from visual and by hand.
If the slower display is desired, press the DEF switch and
change it to step operation. Each time the DEF switch is
pressed, the display changes by 1 step.
HINT:
Codes are displayed from the smaller to the larger num-
bers in order.
To cancel the check mode, press the OFF switch.
050TH±09
I30150
Inspector 's name:
Customer 's NameVIN
Production Date
Licence No.
Odometer Readingkm
Miles Date vehicle
Brought In / /
Date of Problem Occurrence
How Often does Problem Occur?
Weather
Outdoor Temperature / /
Continuous Intermittent ( times a day)
Fine Cloudy Snowy Various / Other
Hot Warm Cool Cold (Approx.F
C)
Symptoms Blower motor does not operate
Blower motor speed does not change
(Always Hi, Always Mid, Always Lo) Air Flow Control
Faulty
Cabin temperature does not go down
Response is slow
Cannot change between FRS and REC
(Always Fresh or always Recirculating)
Will not enter the desired mode Temperature
Control Faulty
Air Inlet Control
Faulty
Vent Control
Faulty
DTC Check1st Time
2nd Time Normal Code Malfunction Code (Code )
Normal Code Malfunction Code (Code )
AIR CONDITIONING SYSTEM Check Sheet
Cabin temperature does not rise
Mode will not change 05±1090
± DIAGNOSTICSAIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
CUSTOMER PROBLEM ANALYSIS CHECK
050TM±13
05±1100
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
PROBLEM SYMPTOMS TABLE
If the normal code is displayed during DTC check although the problem still occurs, check the circuits for
each problem symptom in the order given in the table below, and proceed to the relevant troubleshooting.
SymptomSuspect AreaSee page
Whole functions of the A/C system does not operate.
1. IG power source circuit
2. A/C amplifier assy
3. Engine ECU 1AZ±FSE: 1AZ±FE:
1ZZ±FE/3ZZ±FE:
1CD±FTV:05±1144
05±1098 05±294
05±149 05±5
05±528
Air Flow Control : No blower operation
1. Blower motor circuit
2. Heater relay circuit
3. Blower w/fan motor sub±assy
4. A/C amplifier assy05±1148
05±1146
05±1148
05±1098
Air Flow Control : No blower control1. Blower motor circuit05±1148
Air Flow Control : Insufficient air out
1. Blower w/fan motor sub±assy
2. Blower motor circuit
3. A/C amplifier assy05±1148
05±1148
05±1098
Temperature Control : Cool air does not come out
1. Volume of refrigerant
2. Drive belt tension
3. Refrigerant pressure
4. Air conditioner magnetic valve circut
5. Pressure sensor circuit
6. Air mix control servomotor circuit
7. Air mix damper position sensor circuit
8. Room temp. sensor circuit
9. Ambient temp. sensor circuit
10.A/C amplifier assy55±24
55±46
55±24
05±1151 05±1116
05±1133
05±1122
05±1102
05±1106
05±1098
Temperature Control : Warm air does not come out
1. Air mix control servomotor circuit
2. Air mix damper position sensor circuit
3. Ambient temp. sensor circuit
4. Room temp. sensor circuit
5. A/C amplifier assy
6. Heater radiator05±1133
05±1122
05±1106
05±1102
05±1098
±
Temperature Control : Output air is warmer or cooler than the set
temperature or response is slow.
1. Room temp. sensor circuit
2. Ambient temp. sensor circuit
3. Solar sensor circuit
4. Air mix damper position sensor circuit
5. Air mix control servomotor circuit
6. Evaporator temp. sensor circuit
7. A/C amplifier assy05±1102
05±110605±1113
05±1122
05±1133
05±1109
05±1098
Temperature Control : No temperature control (only Max. cool or Max. warm)
1. Room temp. sensor circuit
2. Ambient temp. sensor circuit
3. Solar sensor circuit
4. Air mix damper position sensor circuit
5. Air mix control servomotor circuit
6. Evaporator temp. sensor circuit
7. A/C amplifier assy05±1102
05±1106
05±1113
05±1122
05±1133
05±1109
05±1098
No air inlet control1. Recirculation damper servomotor circuit
2. A/C amplifier assy05±1153
05±1098
No air outlet control
1. Air outlet damper position sensor circuit
2. Air outlet control servomotor circuit
3. A/C amplifier assy05±1126
05±1136
05±1098
I35353
Recirculation Damper Servo Sub±assy
Mode Damper Servo Sub±assy
Evaporator Temp. Sensor
Evaporator
Airmix Damper Servo Sub±assy
Airmix No.2 Damper
Servo Sub±assy
Blower Motor ControlBlower w/ Fan Motor
Sub±assy
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1097
AVENSIS REPAIR MANUAL (RM1018E)
05C7W±01
05±1166
± DIAGNOSTICSCOMBUSTION TYPE POWER HEATER SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
DIAGNOSTIC TROUBLE CODE CHART
If a malfunction code is displayed during the DTC check, check the circuit listed for that code in the table
below and proceed to the appropriate page.
DTC No.Description of faultComment / Remedy
000No malfunction±
010
011Overvoltage shutoff
Undervoltage shutoffVoltage between 1 and 5 at connector A > 16 V
Voltage between 1 and 5 at connector A < 10.2 V
(Voltage values must be present > 20 seconds)
Check battery, regulator and electrical leads.
012Overheating
Check temperature at temperature or overheating sensor >
125 C
Check water circuit.
014Possible overheating detected
(Hardware threshold value)
Difference of measured values at temperature sensor > 15 C
(min. 70 C water temperature and metering pump in opera-
tion);
Check temperature sensor and overheating sensor, replace if
necessary.
017Overheating detected
(Hardware threshold value)
Temperature at temperature or overheating sensor > 130 C,
emergency OFF if DTC No. 012 or 014 not is applicable;
Check water circuit, temperature sensor and overheating sen-
sor, replace if necessary.
020Glow plug breakCheck glow plug, replace if necessary.
021Glow plug output overloadCheck glow plug, replace if necessary.
030Combustion air blower motor
EMF outside perm. range.Blower impeller or burner motor fammed (frozen solid, dirty,
etc.)
Remedy jam, replace burner motor if necessary.
031Combustion air blower motor breakCheck the lead to combustion air motor (burner motor) for
continuity, replace if necessary.
032Combustion air blower motor short±circuit
Check combustion air blower motor (burner motor), replace if
necessary.
Check supply lead (chafed, etc.).
047Metering pump short±circuitCheck the supply lead to metering pump for short±circuit,
check metering pump, replace if necessary.
048Metering pump breakCheck the supply lead to metering pump for continuity, remedy
break, replace metering pump if necessary.
051Cold blow time exceeded
At start, if flame sensor above 70 C, > 240 sec.;
Check exhaust gas combustion air supply, check flame sen-
sor, replace if necessary.
052Safety time exceeded
When all perm. start attempts used up;
Check the fuel delivery and fuel supply.
Check exhaust gas and combustion air ducts.
054Flame cutout, High settingCheck the fuel delivery and fuel supply.
Check exhaust gas combustion air ducts.
056Flame cutout, LOW setting
Check exhaust gas combustion air ducts.
If combustion OK Check the flame sensor, replace if neces-
sary.
060Temperature conrol sensor break
Check connecting leads.
Resistance value between 2 and 10 connector B > 2 M (if
break)
061Temperature control sensor short±circuit
Check connecting leads.
Resistance value between 2 and 10 at connector B < 2 M (If
short± circuit)
064Flame sensor break
Check connecting leads.
Resistance value between 7 and 14 at connector B > 3,040
(If break)
065Flame sensor short±circuit
Check connecting leads.
Resistance value between 7 and 14 at connector B > 780 (If
short±circuit)
I35396
R±W (*2) R±W (*2, *1) G±Y (*1)
W±B (*1)
W±B
(*1) R±W (*3, *1)
R±W (*3)
R±W (*2)CB1
CK 12 Center J/BP5
Power Heater SWA/C Control Assembly
A1611
J/C
J26H
J27F3IG
IN 6
E2
A
A J16
J/C
Driver Side J/B
DC6
From
HTR Fuse
ILHOTGASIN
*1: 1CD±FTV
*2: LHD
*3: RHD
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1159
AVENSIS REPAIR MANUAL (RM1018E)
HOT GAS HEATER SWITCH CIRCUIT
CIRCUIT DESCRIPTION
Hot gas heater performs only when its switch turns to ON and fulfill the following 6 conditions.
Hot gas heater switch is ON.
Recirculation damper position is FRS.
Blower motor switch is in the position other than OFF.
Ambient temperature varies according to the following condition;
A/C switch ONBelow ±1.5C (32F)
A/C switch OFFBelow 8C (46F)
Air mix damper position is MAX HOT.
Water temperature is 70C (158F) or less.
WIRING DIAGRAM
05C7S±01
I35380
R±W
(*2)J26 J26HH
IE111
IE218
A157
MGV A/C Control Assembly
R±W
(*2)R±W R±B R±Y J/CC4
Condenser
Assembly
12
Driver Side J/B
DC6
DB5
R±W
(*1)
From
HTR Fuse
*1: LHD
*2: RHD
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1157
AVENSIS REPAIR MANUAL (RM1018E)
HOT GAS HEATER MAGNETIC VALVE CIRCUIT
CIRCUIT DESCRIPTION
For the hot gas heater, it is necessary to fulfill the following 6 conditions.
Hot gas heater switch is ON.
Recirculation damper position is FRS.
Blower motor switch is in the position other than OFF.
Ambient temperature varies according to the following condition;
A/C switch ONBelow ±1.5C (32F)
A/C switch OFFBelow 8C (46F)
Air mix damper position is MAX HOT.
Water temperature is 70C (158F) or less.
WIRING DIAGRAM
05C7R±01
I36148
Duty Ratio =A + BA
x 100 (%)
ON 0 VOFF 5 VA
1 cycle Blower Level (Reference)
Si duty (%)
B HI
M8
M7
M6
M5
M4
M3
M2
M1
LO
26.3
30.937.8
44.751.6
58.465.3
74.583.7 100.0
I36133
B5
Blower Motor
Controller
A/C Control Assembly
SI
+B
VM
GND2
3
4
1LB
M
2
1 L±BL±BR
Driver Side J/B
DF2From
HTR
RELAY
L±B
J15
J/C A
IK5
A16 BLW L±B
2
IJ2
1
IJ2
4
IJ2 B±WB
W±B 3
IJ2
B4
Blower Motor
W±B 05±1148
± DIAGNOSTICSAIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
BLOWER MOTOR CIRCUIT
CIRCUIT DESCRIPTION
The blower motor is operated by signals from the A/C amplifier. Blower motor speed signals are transmitted
by changes in the Duty Ratio.
Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity
in one cycle, and then B is the period of non±continuity.
WIRING DIAGRAM
05C7O±01