Page 713 of 801

YH4
GRAND
VITARA
AIR BAG SYSTEM 10B-7
Special Tool (Air Bag Driver/Passenger Load Tool)
(B): 09932-75010
This tool is used only when called for in this section. It is used as
a diagnostic aid and safety device to prevent inadvertent air bag (in-
flator) module deployment and seat belt pretensioner activation.
The load tool has three connectors attached to its case are electri-
cally functional and serve as resistive load substitutions.
No more than two connectors are used at any time.
One of connectors (ªAº: BASE OF COLUMN) is used to substitute
the load of the driver air bag (inflator) module and the contact coil
assembly when it is connected at the base of the column to the air
bag wire harness.
Another connector (ªBº: STEERING WHEEL) is used to substitute
the load of followings.
Driver air bag (inflator) module when it is connected at the top of
the column to the contact coil assembly.
Passenger air bag (inflator) module when it is connected to the
air bag harness connector for passenger air bag (inflator) module.
Driver and passenger seat belt pretensioner when it is connected
to air bag harness connector for driver and passenger seat belt
pretensioner.
The third connector (ªCº: PASSENGER INFLATOR) is not used.
By substituting the resistance of the load tool when called for, a de-
termination can be made as to whether an inflator circuit compo-
nent is causing system malfunction and which component is caus-
ing the malfunction.
The load tool should be used only when specifically called for in the
diagnostic procedures.
Page 714 of 801

YH4
GRAND
VITARA
(A)
10B-8 AIR BAG SYSTEM
INTERMITTENT AND POOR CONNECTIONS
Most intermittent are caused by faulty electrical connections or wir-
ing. When a check for proper connection is requested in a diagnos-
tic flow table, perform careful check of suspect circuits for:
Poor mating of connector halves, or terminals not fully seated in
the connector body (backed out).
Dirt or corrosion on the terminals. The terminals must be clean
and free of any foreign material which could impede proper termi-
nal contact.
However, cleaning the terminal with a sand paper or the like is
prohibited.
Damaged connector body, exposing the terminals to moisture
and dirt, as well as not maintaining proper terminal orientation
with the component or mating connector.
Improperly formed or damaged terminals.
If any abnormality is found, repair or replace as a wire harness as-
sembly.
Check each connector terminal in problem circuits carefully to en-
sure good contact tension by using the corresponding mating termi-
nal included in the connector test adapter kit (special tool).
If contact tension is not enough, reform it to increase contact ten-
sion or replace.
Special Tool (Connector Test Adapter Kit)
(A): 09932-76010
Poor terminal-to-wire connection.
Check each wire harness in problem circuits for poor connection
by shaking it by hand lightly.
If any abnormal condition is found, change the wire harness as-
sembly or component parts with new ones.
Page 715 of 801
YH4
GRAND
VITARA
AIR BAG SYSTEM 10B-9
Wire insulation which is rubbed through, causing an intermittent
short as the bare area touches other wiring or parts of the vehicle.
Wiring broken inside the insulation. This condition could cause a
continuity check to show a good circuit, but if only 1 or 2 strands
of a multi-strand-type wire are intact, resistance could be far too
high.
If any abnormality is found, repair or replace as a wire harness as-
sembly.
Page 716 of 801

YH4
GRAND
VITARA
10B-10 AIR BAG SYSTEM
AIR BAG DIAGNOSTIC SYSTEM CHECK
WARNING:
To avoid deployment when troubleshooting the air bag system, do not use electrical test equipment
such as a battery powered or AC powered voltmeter, ohmmeter, etc., or any type of electrical equipment
other than that specified in this manual. Do not use a non-powered probe type tester.
Instructions in this manual must be followed carefully, otherwise personal injury may result.
CAUTION:
The order in which diagnostic trouble codes are diagnosed is very important. Failure to diagnose the
diagnostic trouble codes in the order specified may result in extended diagnostic time, incorrect diag-
nosis and incorrect parts replacement.
The diagnostic procedures used in this section are designed to find and repair air bag system malfunctions.
To get the best results, it is important to use the diagnostic flow tables and follow the sequence listed below.
A. PERFORM THE ªAIR BAG DIAGNOSTIC SYSTEM CHECK FLOW TABLEº
The ªAir Bag Diagnostic System Check Flow Tableº must be the starting point of any air bag system diagnostics.
The ªAir Bag Diagnostic System Check Flow Tableº checks for proper ªAIR BAGº warning lamp operation, the
ability of the SDM to communicate through ªAIR BAGº warning lamp and whether air bag diagnostic trouble
codes exist.
B. REFER TO THE PROPER DIAGNOSTIC TABLE AS DIRECTED BY THE ªAIR BAG DIAGNOSTIC SYSTEM
CHECK FLOW TABLEº.
The ªAir Bag Diagnostic System Check Flow Tableº will lead you to the correct chart to diagnose any air bag
system malfunctions. Bypassing these procedures may result in extended diagnostic time, incorrect diagnosis
and incorrect parts replacement.
C. REPEAT THE ªAIR BAG DIAGNOSTIC SYSTEM CHECK FLOW TABLEº AFTER ANY REPAIR OR DIAGNOS-
TIC PROCEDURES HAVE BEEN PERFORMED.
Performing the ªAir Bag Diagnostic System Check Flow Tableº after all repair or diagnostic procedures will en-
sure that the repair has been made correctly and that no other malfunctions exist.
Page 717 of 801

YH4
GRAND
VITARA
AIR BAG SYSTEM 10B-11
AIR BAG DIAGNOSTIC SYSTEM CHECK FLOW TABLE
STEPACTIONYESNO
11) Make sure that battery voltage is about
11V or higher.
2) Note ªAIR BAGº warning lamp as ignition
switch is tuned ON.
3) Does ªAIR BAGº warning lamp flash
6 times when ignition switch is tuned ON?Go to step 2.ªAIR BAGº warning lamp
does not come ªONº
Proceed to ªTable Bº
on p.10B-18.
2Does ªAIR BAGº warning lamp keep flashing
(indicating DTC) when ignition switch is
turned ON ?ªAIR BAGº warning
lamp flashes
Proceed to ªTable Cº
on p.10B-20.Go to step 3.
3After flashing 6 times then does
ªAIR BAGº warning lamp turn OFF?Go to step 4.Go to step 5.
41) Check DTC, referring to ªDiagnostic
Trouble Code (DTC) Checkº on
p.10B-12.
2) [Using SUZUKI scan tool]
Is ªNO CODESº displayed ?
NOTE:
If SDM cannot communicate through
serial data circuit, proceed to ªTable
Dº on p.10B-22.
[Not using SUZUKI scan tool]
Is DTC 12 indicated ?Air bag system is in
good condition.NOTE:
As execution of the ªDiag-
nostic Trouble Code (DTC)
Clearanceº will clear all
DTCs, be sure to record all
DTCs before servicing.
An intermittent trouble has
occurred at some place.
Check the connector
harness, etc. related to the
sensed DTC (Refer to
ªIntermittent and Poor
Connectionsº in this section.).
Then clear DTC (Refer to
p.10B-13.) and repeat this
table.
51) Check DTC, referring to ªDiagnostic
Trouble Code (DTC) Checkº on
p.10B-12.
2) [Using SUZUKI scan tool]
Is ªNO CODESº displayed ?
NOTE:
If SDM cannot communicate through
serial data circuit, proceed to ªTable
Dº on p.10B-22.
[Not using SUZUKI scan tool]
Is DTC 12 indicated ?ªAIR BAGº warning
lamp come ªONº
steady
Proceed to ªTable Aº on
p.10B-16.NOTE:
As execution of the ªDiag-
nostic Trouble Code (DTC)
Clearanceº will clear all
DTCs, be sure to record all
DTCs before servicing.
Check and repair according
to Flow Table corresponding
to that DTC.
Page 718 of 801

YH4
GRAND
VITARA
10B-12 AIR BAG SYSTEM
1. Data link connector (DLC)
2. DLC cable adapter
3. DLC cable
-1. ªAIR BAGº
warning lamp
-2. ªAIR BAGº fuse box
-3. ªAIR BAGº
monitor coupler
3-1. Diagnostic switch
terminal
-4. Air bag harness
(covered yellow tube)
EXAMPLE: When driver air bag initiator circuit resistance high (Code No.21) is set
Malfunction indicator lamp
(ªAIR BAGº warning lamp)
Turn ON
Turn OFF
Time (sec.) Code No. 21 Code No. 21 Code No. 21 1
DIAGNOSTIC TROUBLE CODE (DTC) CHECK
[Using SUZUKI scan tool]
1) Turn ignition switch OFF.
2) After setting cartridge to Tech 1, connect it to data link connector
(DLC) located on underside of instrument panel at driver's seat
side.
Special Tool
(A): 09931-76011 (Tech 1)
(B): Mass storage cartridge
(C): 09931-76030
3) Turn ignition switch ON.
4) Read DTC according to instructions displayed on Tech 1 and
print it or write it down. Refer to Tech 1 operator's manual for fur-
ther details.
5) After completing the check, turn ignition switch OFF and discon-
nect Tech 1 from data link connector (DLC).
[Not using SUZUKI scan tool]
1) Check that malfunction indicator lamp (ªAIR BAGº warning
lamp) comes ON when ignition switch is turned ON.
If it does not come ªONº, proceed to ªTable Bº on p.10B-18.
2) Using service wire, ground diagnosis switch terminal in monitor
coupler.
3) Read DTC from flashing pattern of malfunction indicator lamp
(ªAIR BAGº warning lamp). (Refer to ªDiagnostic Trouble Code
Tableº on p.10B-14 and 10B-15.)
4) After completing the check, turn ignition switch OFF and discon-
nect service wire from ªAIR BAGº monitor coupler.
Page 719 of 801

YH4
GRAND
VITARA
1. Data link connector
2. DLC cable adapter
3. DLC cable
1sec. 1sec.About 10 seconds
Open
Short-1. ªAIR BAGº warning lamp
-2. ªAIR BAGº fuse box
-3. ªAIR BAGº monitor coupler
3-1. Diagnostic switch terminal
-4. Air bag harness (covered yellow tube)1
AIR BAG SYSTEM 10B-13
DIAGNOSTIC TROUBLE CODE (DTC) CLEARANCE
[Using SUZUKI scan tool]
1) Turn ignition switch OFF.
2) Connect Tech 1 to data link connector (DLC) in the same manner
as when making this connection for DTC check.
Special Tool
(A): 09931-76011 (Tech 1)
(B): Mass storage cartridge
(C): 09931-76030
3) Turn ignition switch ON.
4) Erase DTC according to instructions displayed on Tech 1.
Refer to Tech 1 operator's manual for further details.
5) After completing the check, turn ignition switch OFF and discon-
nect Tech 1 from data link connector (DLC).
6) Perform ªDiagnosis Trouble Code (DTC) Checkº and confirm
that normal DTC (NO CODES) is displayed and not malfunction
DTC.
NOTE:
If DTC 51 or DTC 71 is stored in SDM, it is not possible to
clear DTC.
[Not using SUZUKI scan tool]
1) Turn ignition switch ON and wait about 6 seconds or more.
2) Using service wire, repeat shorting and opening between diag-
nosis switch terminal and ground terminal on ªAIR BAGº monitor
coupler 5 times at about 1 second intervals.
3) Perform ªDiagnosis Trouble Code (DTC) Checkº and confirm
that normal DTC (DTC 12) is displayed and not malfunction
DTC.
NOTE:
If DTC 51 or DTC 71 is stored in SDM, it is not possible to
clear DTC.
Page 720 of 801
YH4
GRAND
VITARA
10B-14 AIR BAG SYSTEM
DIAGNOSTIC TROUBLE CODE TABLE (Page 1 of 2)
EXAMPLE: WHEN DRIVER AIR BAG INITIATOR CIRCUIT RESISTANCE HIGH (CODE NO.21) IS SET
Turn ON
Turn OFF
0.30.3 1.0 3.0 3.0 Malfunction indicator lamp
(ªAIR BAGº warning lamp)Code No. 21 Code No. 21 Code No. 21
Time (sec.)
DIAGNOSTIC TROUBLE CODEDIAGNOSISNO.MODEDIAGNOSIS
12Normal±±±±±
15Resistance high
16Passenger
air bag
Resistance low
18
air bag
circuitShort to ground
19Short to power circuit
21Resistance high
Diagnose trouble
according to ªDiagnos-
tic Flow Tableºcorre-
22
Driver air bag
Resistance low
tic Flow Table corre-
sponding to each code
No.
24
g
circuitShort to ground
25Short to power circuit
31Power
source
Too high
32
source