Page 81 of 801

YH4
GRAND
VITARA
3. Bubbles
1B-10 AIR CONDITIONING (OPTIONAL)
QUICKLY CHECKING OF REFRIGERANT
CHARGE (IF EQUIPPED WITH SIGHT GLASS)
CHARGE OF REFRIGERANT
The following procedure can be used for quickly checking whether
the A / C system has a proper charge of refrigerant or not.
Run engine at fast idle, and operate A / C at its max. cooling capacity
for a few minutes. Then, look at the sight glass (1) on receiver / dryer
(2) and compare what is observed with the symptoms listed in
ªCHECKING REFRIGERANT CHARGEº table given below.
CHECKING REFRIGERANT CHARGE
CONDITIONPOSSIBLE CAUSESCORRECTION
Bubbles observed in sight glassInsufficient charge of refrigerant in
systemCheck system for leaks with a leak
tester.
No bubbles observed in sight glassNo charge or proper or too much
charge of refrigerant in systemRefer to the following item.
No temperature difference
between compressor inlet and
outletEmpty or nearly empty systemRecovery, evacuate and charge
system and then check it for leaks
with a leak tester.
Noticeable temperature difference
between compressor inlet and
outletProper or too much charge of
refrigerant in systemRefer to the following item.
When A / C is turned OFF,
refrigerant in sight glass clears
immediately and remains clearToo much charge of refrigerant in
systemDischarge excess charge of
refrigerant to adjust it to a specified
charge.
When A / C is turned OFF,
refrigerant in sight glass once
produces bubbles and then clearsProper charge of refrigerant in
systemNo correction needed because
charge of refrigerant is normal.
Page 82 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-11
COMPRESSION SYSTEM DIAGNOSIS
Compressor troubles are mainly following three types: gas leakage, noise and insufficient pressure.
Compressor gas leakages in most cases develop from the shaft seal. When detecting gas leakage, always use
a leak tester. If a small amount of oil seeps out from the shaft seal, there is no necessity of replacing the seal. The
shaft seal has been designed to allow a small amount of oil to leak out for lubricating purpose. Thus, the shaft seal
should be replaced only when a large amount of compressor oil is leaking out or when gas leakage is discovered
by using gas tester.
In regard to noise and insufficient pressure, repairs should be made only after diagnosing the trouble properly.
CONDITION
POSSIBLE CAUSESCORRECTION
Noise from compressorDefective bearing
Defective cylinder and / or shaftReplace.
Replace.
Noise from magnetic clutchDefective bearing
Defective clutch faceReplace.
Replace.
Insufficient coolingDefective gasketReplace.
Defective reed valveReplace.
Not rotatingLocked compressor
Seized magnetic clutch
Rotating parts seized by insufficient oil
amountReplace.
Replace.
Replace.
Oil and / or gas leakageDefective seal
Defective O-ringReplace.
Replace.
Page 83 of 801

YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-12 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15C ± 35C (59F ± 95F).
2) Make sure that high pressure valve (1) and low pressure valve
(2) of manifold gauge are firmly closed.
3) Connect high pressure charging hose (3) to high pressure ser-
vice valve (5) on vehicle, and connect low pressure charging
hose (4) to low pressure service valve (6) on vehicle.
4) Bleed the air in charging hoses (3), (4) by loosening their respec-
tive nuts on manifold gauge, utilizing the refrigerant pressure.
When a hiss is heard, immediately tighten nut.
CAUTION:
Do not interchange high and low pressure charging
hoses by mistake.
5) Warm up engine to normal operating temperature (engine cool-
ant temperature at 80 ± 90C (176 ± 194F)) and keep it at spe-
cified idle speed. (Radiator cooling fan should not be working
when checking pressure and temperature.)
6) Turn A / C switch ON, and set blower switch at ªHIº (4th position),
temperature control knob at ªCOOLº, air outlet control knob at
ªFACEº, fresh / circulation control knob at ªCIRCULATIONº.
(Confirm that A / C compressor and condenser fan are working.)
7) Keep all windows, doors and engine food open.
Ambient temperature
15 ± 35C (59F ± 95F)
Engine rpmKeep to 1,500 rpm.
Blower motor switchMax. (4th position)
Temperature controlMax. cool
Air outlet controlFace
Vehicle doorsAll open
Air inlet door positionRecirculation
8) With about 20 mm (0.8 in.) of dry bulb thermometer (1) inserted
into center duct air outlet and another one set near evaporator
air inlet, read temperature indicated on each thermometer.
Page 84 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-13
9) Check for each pressure of low side and high side if it is within
shaded range of graph.
If each gauge reading is out of specified pressure, correct de-
fective part referring to following Test Diagnosis table.
Example:
Gauges should read as follows when ambient
temperature is 30C.
Pressure on high pressure
gauge (HI):1400 ± 1750 kPa
14.0 ± 17.5 kg / cm
2
Pressure on high pressure
gauge (LO):230 ± 350 kPa
2.3 ± 3.5 kg / cm
2
NOTE:
Pressure registered on gauge varies with ambient temper-
ature. Therefore, use left graphs when determining if pres-
sures are normal or not.
10) Check inlet port temperature-to-outlet port temperature rela-
tionship using graph.
For example, if evaporator inlet port temperature is 25C
(77F) and center duct air outlet temperature is 8C (46.4F),
their crossing point is within acceptable range as shown in
graph.
11) If crossing point is out of acceptable range, diagnose trouble
referring to following Performance Diagnosis table.
Page 85 of 801

YH4
GRAND
VITARA
1B-14 AIR CONDITIONING (OPTIONAL)
HIGH PRESSURE CAUGE LOW PRESSURE GAUGE THERMOMETER AT
CENTER DUCT
Insufficient
cooling of
condenser
PERFORMANCE DIAGNOSIS TABLE
TESTING RESULTSPOSSIBLE CAUSEREMEDY
Pressure high
(ªAº area of high side
graph)Refrigerant overcharged
Expansion valve frozen or clogged
Clogged refrigerant passage of high side
Condenser fan malfunction
Dirty or bent condenser fins
Compressor malfunction (Insufficient oil etc.)
Engine overheatRecharge
Check expansion valve
Clean or replace
Check condenser fan
Clean or repair
Check compressor
Check engine cooling
system
Pressure low
(ªBº area of high side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check for leakage, repair if
necessary and recharge
Check expansion valve
Check compressor
Pressure high
(ªAº area of low side
graph)Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check expansion valve
Check compressor
Pressure low
(ªBº area of low side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
narrow)
Clogged refrigerant passage (Crashed pipe)Check for leakage, repair if
necessary and recharge
Check expansion valve
Repair or replace
Outlet air temperature
at center duct is high
(Crossing point is in
area ªAº)Insufficient or excessive charge of refrigerant
Dirty or bent evaporator fins
Air leakage from cooling (heater) unit or air
duct
Malfunctioning, switchover function of damper
in cooling (heater) unit
Compressor malfunctionCheck refrigerant
pressure
Clean or repair
Repair or replace
Repair or replace
Check compressor
Outlet air temperature
at center duct is low
(Crossing point is in
area ªBº)Insufficient air volume from center duct
(Heater blower malfunction)
Compressor malfunctionCheck blower motor and
fan
Check compressor
NOTE:
If ambient temperature is within 30 ± 35C (85 ± 95F), it is possible to do using next page table for more
detail diagnosis.
Page 86 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-15
AMBIENT TEMPERATURE WITHIN 30 ± 35C (85 ± 95F)
CONDITION
MANIFOLD
GAUGEMPa
(kg/cm2)
(psi)DETAILCAUSECORRECTION
LoHi
0.23 ± 0.35
(2.3 ± 3.5)
(33 ± 50)1.4 ± 1.75
(14 ± 17.5)
(200 ± 249)
Normal condition.ÐÐÐÐ
Negative
pressure0.5 ± 0.6
(5 ± 6)
(71.2 ± 85.3)
The low pressure side
reads a negative pressure,
and the high pressure side
reads an extremely low
pressure.
Presence of frost around
tubing to and from receiver /
dryer and expansion valve. Dust particles or water
droplets are either stuck or
frozen inside expansion
valve, preventing the
refrigerant from flowing.Clean expansion valve.
Replace it if it cannot be
cleaned.
Replace receiver / dryer.
Evacuate the A / C
system and recharge
with fresh refrigerant.
Normal:
0.23 ± 0.35
(2.3 ± 3.5)
(33 ± 50)
Abnormal:
Negative
pressureNormal:
1.4 ± 1.75
(14 ± 17.5)
(200 ± 249)
Abnormal:
0.69 ± 0.98
(7 ± 10)
(100 ± 142) During A / C operation, the
low pressure side
sometimes indicates
negative pressure, and
sometimes normal
pressure. Also high
pressure side reading
fluctuates between the
abnormal and normal
pressure.Expansion valve is frozen
due to moisture in the
system, and temporarily
shuts off the refrigeration
cycle.Replace expansion
valve.
Replace receiver / dryer.
Evacuate A / C system
and recharge with fresh
refrigerant.
0.05 ± 0.15
(0.5 ± 1.5)
(4.2 ± 21.3)
0.69 ± 0.98
(7 ± 10)
(100 ± 142)
Both low and high pressure
sides indicate low readings.
Continuous air bubbles are
visible through sight glass.
Output air is slightly cold.Insufficient refrigerant in
system. (Refrigerant
leaking)Using a gas leak
detector, check for leaks
and repair as necessary.
Recharge refrigerant to a
specified amount.
If the pressure reading is
almost 0 when the
manifold gauges are
attached, check for any
leaks, repair them, and
evacuate the system.
0.4 ± 0.6
(4 ± 6)
(56.9 ± 85.3)
Pressure on low pressure
side is high.
Pressure on high pressure
side is low.
Both pressure becoming
equal right after A / C is
turned OFF.Internal leak in compressor.Inspect compressor and
repair or replace as
necessary.
035 045
High pressure reading on
both low and high pressure
sides.
Air bubbles are not visible
even when engine rpm is
lowered.Overcharged A / C system.
Faulty condenser cooling
operation.
Faulty condenser fan
operation.Adjust refrigerant to
specified amount.
Clean condenser.
Inspect and repair
condenser fan.
0.35 ± 0.45(3.5 ± 4.5)
(50 ± 64)
1.96 ± 2.45
(20 ± 25)
(285 ± 355)
High pressure reading on
both low and high pressure
sides.
Low pressure side tubing is
not cold when touched.
Air bubbles are visible
through sight glass.Presence of air in A / C
system. (Improperly
evacuated)Replace receiver / dryer.
Inspect quantity of
compressor oil and
presence of
contaminants in oil.
Evacuate system and
recharge with fresh
refrigerant.
0.45 ± 0.55
(4.5 ± 5.5)
(64 ± 78)
High pressure reading on
both low and high pressure
sides.
Large amount of frost or
dew on the low pressure
side tubing.Faulty expansion valve.
Refrigerant flow is not
regulated properly.Replace expansion
valve.
Page 87 of 801
YH4
GRAND
VITARA
1. Blower motor main relay
2. Blower motor
3. Blower motor resistor
4. Blower motor switch
5. A / C controller
6. ECM
7. Heater mode control switch
8. Evaporator temperature sensor
9. Refrigerant pressure switch10. Compressor relay
11. Compressor
12. Condenser cooling fan relay
13. Condenser cooling fan
14. Fuse box
15. A / C fuse 25 A
16. Ignition switch
17. Main fuse box
18. Battery main fuse 80 A19. Battery
20. Generator
21. Ignition main fuse 60 A
22. Heater/A/C main fuse 60 A
23. Ignition / meter fuse 20 A
24. Rear defogger fuse 15 A
25. Heater fuse 30 A
26. Compressor thermal switch
(only IWATA production vehicle)
FOR LH VEHICLE
1B-16 AIR CONDITIONING (OPTIONAL)
WIRING CIRCUIT
Page 88 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-17
1. Blower motor main relay
2. Blower motor
3. Blower motor resistor
4. Blower motor switch
5. A / C controller
6. ECM
7. Heater mode control switch
8. Evaporator temperature sensor
9. Refrigerant pressure switch
FOR RH VEHICLE
10. Compressor relay
11. Compressor
12. Condenser cooling fan relay
13. Condenser cooling fan
14. Fuse box
15. A / C fuse 25 A
16. Ignition switch
17. Main fuse box
18. Battery main fuse 80 A19. Battery
20. Generator
21. Ignition main fuse 60 A
22. Heater/A/C main fuse 60 A
23. Ignition / meter fuse 20 A
24. Rear defogger fuse 15 A
25. Heater fuse 30 A
26. Compressor thermal switch
(only IWATA production vehicle)