Page 97 of 801

YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-26 AIR CONDITIONING (OPTIONAL)
CHARGING
CAUTION:
ALWAYS CHARGE THROUGH LOW PRESSURE-SIDE of A / C system at after the initial charging is per-
formed from the high-pressure side with the engine stopped.
NEVER CHARGE TO HIGH PRESSURE-SIDE of A / C system with engine running.
Do not charge while compressor is hot.
When installing tap valve to refrigerant container to make a hole there through, carefully follow direc-
tions given by manufacturer.
A pressure gauge should always be used before and during charging.
The refrigerant container should be emptied of refrigerant when discarding it.
The refrigerant container should not be heated up to 40C (104F) or over.
Refrigerant container should not be reversed in direction during charging. Reversing in direction
causes liquid refrigerant to enter compressor, causing troubles, such as compression of liquid refrig-
erant and the like.
NOTE:
The air conditioning system contains HFC-134a (R-134a).
Described here is a method to charge the air conditioning system with refrigerant from the refrigerant ser-
vice container.
When charging refrigerant recovered by using the refrigerant and recycling equipment (when recycling
refrigerant), follow the procedure described in the equipment manufacturer's instruction manual.
The initial charging of the A / C system is performed from the high-
pressure side with the engine stopped.
And next, this method must be followed by charging from the low-
pressure side with the engine running.
1) Check to make sure that hoses are routed properly after eva-
cuating the system.
2) Connect Low-side hose (1) and High side hose (2) of the man-
ifold gauge set (3) in position. Thus open refrigerant container
valve (4) to purge the charging line.
3) Open the high-pressure side valve (6) and charge refrigerant to
system.
4) After a while, open the low-pressure side valve (5) and close the
high-pressure side valve (6).
WARNING:
Make sure that high pressure-side valve is closed se-
curely.
5) Start engine and keep engine speed at 1500 r / min. Then, oper-
ate air conditioning.
6) Charge A / C system with refrigerant in vapor state. At this time,
refrigerant container should be held upright.
Page 98 of 801

YH4
GRAND
VITARA
1. ªHissº
AIR CONDITIONING (OPTIONAL) 1B-27
7) When refrigerant container (3) is emptied, use following proce-
dure to replace it with a new refrigerant container (3).
a. Close low pressure valve.
b. Replace empty container (3) with a refrigerant container
which has been charged with refrigerant. When using refrig-
erant container tap valve (4), use following procedure for re-
placement.
i) Retract needle (1) and remove refrigerant container tap
valve (4) by loosening its plate nut (2).
ii) Install previously-removed refrigerant container tap valve
(4) to a new refrigerant container (3).
c. Purge any air existing in center charging hose.
When using refrigerant container tap valve, use following
procedure to purge air.
i) Once fully tighten refrigerant container tap valve and then
loosen (open) plate nut slightly.
ii) Open low pressure valve of manifold gauge set a little.
iii) As soon as refrigerant comes out with a ªhissº through a
clearance between refrigerant container and tap valve,
tighten plate nut as well as manifold gauge set low pres-
sure valve.
iv) Turn handle of tap valve clockwise so that its needle is
screwed into the new container to make a hole for refriger-
ant flow.
Page 99 of 801
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-28 AIR CONDITIONING (OPTIONAL)
8) After the system has been charged with specified amount of re-
frigerant or when low pressure gauge (1) and high pressure
gauge (2) have indicated about 2 and 15 kg / cm
2 respectively,
close low pressure side vale (3) of manifold gauge set (4). If
equipped with sight glass in this time, look into the sight glass (6)
of condenser outlet pipe (5) and check that there are no bubbles
(7) in it, which means that the system is fully charged.
Low pressure gauge when charged with specified amount:
About 200 ± 300 kPa (2 ± 3 kg / cm
2, 29 ± 43 psi)
(At A / C inlet temperature 30 ± 35C, 86 ± 95F)
High pressure gauge when charged with specified amount:
About 1370 ± 1670 kPa (14 ± 17 kg / cm
2, 200 ± 244 psi)
(At A / C inlet temperature 30 ± 35C, 86 ± 95F)
Page 100 of 801

YH4
GRAND
VITARA
1. Electric leak detector
AIR CONDITIONING (OPTIONAL) 1B-29
REMOVING MANIFOLD GAUGE SET
When A / C system has been charged with a specified amount of re-
frigerant, remove manifold gauge set as follows:
1) Close low pressure-side valve of manifold gauge set, (The high
pressure-side valve is closed continuously during the process
of charging.).
2) Close refrigerant container valve.
3) Stop engine.
4) Using shop rag, remove charging hoses from service valves.
This operation must be performed rapidly.
WARNING:
High pressure-side is naturally under high pressure.
So, care must be used to protect your eyes and skin.
5) Put caps on service valves.
LEAK-TESTING REFRIGERANT SYSTEM
Whenever a refrigerant leak is suspected in the system or any ser-
vice operation has been performed which may result in disturbing
lines or connections, it is advisable to test for leaks.
Common sense should be used in performing any refrigerant leak
test, since the need and extent of any such test will, in general, de-
pend upon the nature of a complaint and the type of a service per-
formed on the system.
LIQUID LEAK DETECTORS
There are a number of fittings and places throughout the air condi-
tioning system where a liquid leak detector solution may be used
to pinpoint refrigerant leaks.
By merely applying the solution to the area in question with a swab,
bubbles will form within seconds if there is a leak.
For confined areas, such as sections of the evaporator and con-
denser, an electronic (gas) leak detector is more practical for deter-
mining leaks.
WARNING:
To prevent explosions or fires, make sure that there are no
flammables in the vicinity.
When exposed to fire, the refrigerant turns into a poison-
ous gas (phosgene). Do not inhale this gas.
Page 101 of 801

YH4
GRAND
VITARA
1. Suction hose
2. Discharge hose
3. Liquid pipe
4. Condenser outlet pipe
5. Expansion valve
6. Dual pressure switch
7. Suction pipe
: Apply compressor oil
(refrigerant oil) to O-ring.
1B-30 AIR CONDITIONING (OPTIONAL)
ON-VEHICLE SERVICE
WARNING:
Should refrigerant HFC-134a (R-134a) strike your eye(s), consult a doctor immediately.
DO NOT USE YOUR HAND TO RUB AFFECTED EYE(S).
Instead, use quantities of fresh cold water to splash it over affected area to thus gradually raise its
temperature above the freezing point.
Obtain proper treatment as soon as possible from a doctor or eye specialist.
Should liquid refrigerant HFC-134a (R-134a) get on your skin, such affected part should be treated
in the same manner as when skin is frostbitten or frozen.
CAUTION:
None of refrigerant, compressor oil and component parts is interchangeable between two types of A / C:
one using CFC-12 (R-12) and the other using HFC-134a (R-134a).
(For identification between these two types, refer to page 1B-2).
When replenishing or changing refrigerant and compressor oil and when replacing parts, make sure
that the material or the part to be used is appropriate to the A / C installed in the vehicle being serviced.
Use of incorrect one will result in leakage of refrigerant, damage in parts or other faulty condition.
PRECAUTION
When servicing air conditioning system, the following rules must be observed.
PIPING
When connecting hoses and pipes, apply a few drops of compressor oil (refrigerant oil) to seats of coupling nuts
and O-ring.
Never use heat for bending pipes. When bending a pipe, try to make its bending radius as slight as possible.
Keep internal parts of air conditioning free from moisture and dirt. When disconnecting any line from system,
install a blind plug or cap to the fitting immediately.
When tightening or loosening a fitting, use two wrenches, one for turning and the other for support.
Page 102 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-31
Tighten flared nuts to specified torque.
Tightening Torque (Flared Nut Used for)
8 mm pipe: 13 N
.m (1.3 kg-m, 9.5 lb-ft)
14.5 mm pipe: 23 N
.m (2.3 kg-m, 16.6 lb-ft)
16 mm pipe: 33 N
.m (3.3 kg-m, 23.8 lb-ft)
Route drain hose so that drained water does not make any contact to vehicle components.
HANDLING REFRIGERANT HFC-134a (R-134a)
When handling refrigerant, always wear goggles to protect your eyes.
Avoid you direct contact to liquid refrigerant.
Do not heat refrigerant container higher than 40C (104F).
Do not discharge refrigerant into atmosphere.
Do not allow liquid refrigerant to touch bright metals. Refrigerant combined with moisture is corrosive and will
tarnish surfaces of bright metals including chrome.
After recovering refrigerant from system, the amount of compressor oil removed must be measured and the same
amount added to the system.
REFRIGERANT RECOVERY
When discharging refrigerant out of A / C system, always recover it by using refrigerant recovery and recycling
equipment. Discharging refrigerant HFC-134a (R-134a) into atmosphere would cause adverse effect to environ-
ments.
NOTE:
When handling recovery and recycling equipment, be sure to follow the instruction manual for the equip-
ment.
REFRIGERANT CHARGE
Charge a proper amount of refrigerant to A / C system according to charging procedure described in recovery, evac-
uation and charging.
CAUTION:
Do not perform an additional refrigerant charging to A / C system. This cause it to overcharge.
Page 103 of 801

YH4
GRAND
VITARA
1. New compressor
2. Removed compressor
3. Excess oil (A ± B)
1B-32 AIR CONDITIONING (OPTIONAL)
REPLENISHING COMPRESSOR OIL
When replacing air conditioning parts with new ones, it is necessary
to replenish oil by the amount supposedly remaining in each part.
When changing gas only
When it is unavoidable to change gas without replacing any compo-
nent part for engine removal and installation or for some other rea-
son, replenish 20 cc oil. When replenishing gas only, oil replenish-
ment it not necessary.
When replacing compressor
Compressor oil is sealed in each new compressor by the amount
required for air conditioner cycle. Therefore, when using a new
compressor for replacement, drain oil from it by the amount calcu-
lated as follows.
ªCº = ªAº ± ªBº
ªCº: Amount of oil to be drained
ªAº: Amount of oil sealed in a new compressor
ªBº: Amount of oil remaining in removed compressor
When replacing other part
Replaced partAmount of compressor oil
to be replenished
Evaporator25 cc
Condenser15 cc
Receiver / dryer20 cc
Hoses10 cc each
Pipes10 cc each
Page 104 of 801

YH4
GRAND
VITARA
2. Bolt
For CAMI production vehicle
For IWATA production vehicle
AIR CONDITIONING (OPTIONAL) 1B-33
A / C CONDENSER ASSEMBLY
INSPECTION
Check
a) condenser fins for blockage
b) condenser fittings for leakage
c) condenser fins for damage
Clogged condenser fins should be washed with water, and should
be dried with compressed air.
CAUTION:
Be careful not to damage condenser fins. If condenser fin is
bent, straighten it by using a screwdriver or pair of pliers. If
any leakage is found from fitting or tube, repair or replace
condenser.
REMOVAL
1) Disconnect negative (±) cable at battery.
2) Recover refrigerant by using recovery and recycling equipment.
Be sure to follow the instruction manual for the equipment.
The amount of compressor oil removed must be measured and
the same amount added to the system.
3) Remove front bumper assembly and remove lower stay (1) if
equipped (Refer to Section 9 ªBODY SERVICEº).
4) Disconnect compressor discharge hose (1) from condenser in-
let fittings.
CAUTION:
As soon as above hose and pipe are disconnected, cap
opened fittings so that moisture and dust do not enter
condenser.