YH4
GRAND
VITARA
1. Check contact tension by inserting and removing
just once.
2. Check each terminal for bend and proper alignment.
GENERAL INFORMATION 0A-15
INTERMITTENT AND POOR CONNECTION
Most intermittent are caused by faulty electrical connections or wir-
ing, although a sticking relay or solenoid can occasionally be at
fault. When checking it for proper connection, perform careful
check of suspect circuits for:
Poor mating of connector halves, or terminals not fully seated in
the connector body (backed out).
Dirt or corrosion on the terminals. The terminals must be clean
and free of any foreign material which could impede proper termi-
nal contact.
However, cleaning the terminal with a sand paper or the like is
prohibited.
Damaged connector body, exposing the terminals to moisture
and dirt, as well as not maintaining proper terminal orientation
with the component or mating connector.
Improperly formed or damaged terminals.
Check each connector terminal in problem circuits carefully to en-
sure good contact tension by using the corresponding mating ter-
minal.
If contact tension is not enough, reform it to increase contact ten-
sion or replace.
YH4
GRAND
VITARA
1A
HEATER AND VENTILATION 1A-1
SECTION 1A
HEATER AND VENTILATION
WARNING:
For vehicles equipped with Supplement Restraint (Air Bag) System
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to ªAir Bag System Components and Wiring Location Viewº under ªGener-
al Descriptionº in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and ªService Precau-
tionsº under ªOn-Vehicle Serviceº in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either or these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
ªLOCKº position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
NOTE:
The link mechanism of the heater varies depending on the specifications.
CONTENTS
GENERAL DESCRIPTION1A- 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Body Ventilation1A- 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DIAGNOSIS1A- 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnosis Table1A- 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Circuit1A- 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE1A- 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Unit1A- 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Motor1A- 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Motor Relay1A- 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Motor Resistor1A- 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Mode Control Switch1A-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Mode Control Actuator1A-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Control Lever Assembly 1A-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Control Cables1A-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Unit1A-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rear Duct1A-19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
YH4
GRAND
VITARA
1A-4 HEATER AND VENTILATION
FOR LH VEHICLE
FOR RH VEHICLE
1. From ignition switch 1
2. From ignition switch 2
3. From blower fuse
4. Head light relay
5. To A / C controller6. Blower motor relay
7. Blower motor switch
8. Blower resistor
9. Blower motor
10. To ECM11. To illumination controller
(if equipped) or body ground
12. Mode control actuator
13. Mode control switch
14. From main fuse15. TAIL fuse 15 A
16. IG METER fuse 20 A
17. HEATER fuse 30 A
18. REAR DEFG fuse 15 A
19. Drive circuit
WIRING CIRCUIT
YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-5
1. Blower unit
2. Blower motor resistor
3. Blower motor relay
4. Blower fan
5. Blower motor
3. Cover
ON-VEHICLE SERVICE
BLOWER UNIT
REMOVAL
1) Disconnect negative (±) cable at battery.
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Remove passenger lower member (1).
4) Remove ECM (1) with bracket (2) from blower motor unit (4).
5) Disconnect blower motor (1), blower motor relay (2) and resistor
lead wires (3) at couplers.
YH4
GRAND
VITARA
1A-8 HEATER AND VENTILATION
BLOWER MOTOR RELAY
REMOVAL
1) Disconnect negative (±) cable at battery.
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Open glove box, then remove screw.
4) Remove glove box.
5) Disconnect relay coupler.
6) Remove blower motor relay (1) by removing its fastening screw (2).
INSPECTION
1) Check that there is no continuity between terminal ªcº and ªdº.
If there is continuity, replace relay.
2) Connect battery positive (+) terminal to terminal ªbº of relay.
Connect battery negative (±) terminal ªaº of relay.
Check continuity between terminal ªcº and ªdº.
If there is no continuity when relay is connected to the battery,
replace relay.
YH4
GRAND
VITARA
1B-2 AIR CONDITIONING (OPTIONAL)
Condenser Dryer (Receiver / Dryer) 1B-36. . . . . .
Air Filter Element 1B-37. . . . . . . . . . . . . . . . . . . . .
Cooling Unit (Evaporator) 1B-39. . . . . . . . . . . . . .
Expansion Valve 1B-42. . . . . . . . . . . . . . . . . . . . .
A / C Evaporator Thermistor (Evaporator
Temperature Sensor) 1B-43. . . . . . . . . . . . . . . .
Refrigerant Pipes and Hoses 1B-44. . . . . . . . . . .
A / C Switch 1B-45. . . . . . . . . . . . . . . . . . . . . . . . . .
A / C Controller 1B-46. . . . . . . . . . . . . . . . . . . . . . . .
Dual Pressure Switch 1B-47. . . . . . . . . . . . . . . . . A / C Compressor Relay and A / C
Condenser Cooling Fan Relay 1B-48. . . . . . . .
Compressor Assembly 1B-49. . . . . . . . . . . . . . . .
Magnet Clutch Assembly
(For Denso Compressor) 1B-53. . . . . . . . . . .
Magnet Clutch Assembly
(For Seiko Seiki Compressor) 1B-56. . . . . . .
Lip Type Seal (For Seiko Seiki) 1B-59. . . . . . .
REQUIRED SERVICE MATERIAL1B-61 . . . . . . . .
SPECIAL TOOLS1B-61 . . . . . . . . . . . . . . . . . . . . . .
YH4
GRAND
VITARA
1B-6 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS
GENERAL
ConditionPossible CauseCorrection
Cool air won't come out
(A / C system won't
operative)No refrigerant
Fuse blown
A / C switch faulty
Blower motor switch faulty
A / C thermistor faulty
Dual pressure switch faulty
Wiring or grounding faulty
A / C ON permission signal in ECM
faulty
A / C controller and its circuit faultyRecover, evacuation and charging.
Check ªIG METERº fuse, ªREAR DEFGº
fuse, and ªA / C FUSEº and check for
short circuit to ground.
Check A / C switch.
Check blower motor switch.
Check A / C evaporator thermistor.
Check dual pressure switch.
Repair as necessary.
Check ON permission signal.
Check A / C controller and its circuit.
Cool air won't come out
(A / C compressor won't
operative)Magnet clutch faulty
Compressor relay faulty
Compressor thermal switch faulty
(if equipped)
Drive belt loose or broken
Compressor faulty
A / C ON permission signal in ECM
faulty
A / C controller faultyCheck magnet clutch.
Check compressor thermal switch.
Check compressor relay.
Adjust or replace drive belt.
Check compressor.
Check ON permission signal.
Check A / C controller.
Cool air won't come out
(A / C condenser cooling
fan motor won't
operative)Condenser cooling fan relay faulty
Wiring or grounding faulty
ªA / C condenser cooling fan relayº
signal in ECM faulty
Condenser cooling fan motor faultyCheck condenser cooling fan relay.
Repair as necessary.
Check A / C condenser cooling fan relay
signal.
Check condenser cooling fan motor.
Cool air won't come out
(Blower motor won't
operative)Fuse blown
Blower motor relay faulty
Blower motor resistor faulty
Blower motor switch faulty
Wiring or grounding faulty
Blower motor faultyCheck ªHEATER FUSEº, ªREAR DEFGº
fuse and check for short circuit to
ground.
Check blower motor relay.
Check blower motor resistor.
Check blower motor switch.
Repair as necessary.
Check blower motor.
Cool air won't come out
or insufficient cooling
(A / C system normal
operative)Insufficient or excessive charge of
refrigerant
Refrigerant leak in system
Condenser clogged
A / C evaporator clogged or frosted
A / C thermistor faulty
A / C controller faulty
Expansion valve faulty
Drive belt slipping
Magnetic clutch faultyCheck charge of refrigerant.
Check system for leaks.
Check condenser.
Check A / C evaporator.
Check A / C thermistor.
Check A / C controller.
Check expansion valve.
Check or replace drive belt.
Check magnetic clutch.
YH4
GRAND
VITARA
1. Blower motor main relay
2. Blower motor
3. Blower motor resistor
4. Blower motor switch
5. A / C controller
6. ECM
7. Heater mode control switch
8. Evaporator temperature sensor
9. Refrigerant pressure switch10. Compressor relay
11. Compressor
12. Condenser cooling fan relay
13. Condenser cooling fan
14. Fuse box
15. A / C fuse 25 A
16. Ignition switch
17. Main fuse box
18. Battery main fuse 80 A19. Battery
20. Generator
21. Ignition main fuse 60 A
22. Heater/A/C main fuse 60 A
23. Ignition / meter fuse 20 A
24. Rear defogger fuse 15 A
25. Heater fuse 30 A
26. Compressor thermal switch
(only IWATA production vehicle)
FOR LH VEHICLE
1B-16 AIR CONDITIONING (OPTIONAL)
WIRING CIRCUIT