Page 828 of 969
SENSOR INSPECTION FOR AIR CONDITIONING SYSTEM ± AC005-04 December 16, 2004
Page 2 of 12
1. Inspect Room Temperature Sensor.
A. Measure the sensor resistance.
Resistance Value at 775F
(255C)1700 +/± 85W
NOTE:
Even slightly touching the sensor
may change the resistance value.
Be sure to hold the connector of
the sensor.
When measuring, the sensor
temperature must be the same as
the ambient temperature.
HINT:
As the temperature increases, the
resistance decreases.
TEMPERATURE 5F (5C)SPECIFICATION kW
50 (10)3.00 to 3.73
59 (15)2.45 to 2.88
68 (20)1.95 to 2.30
77 (25)1.60 to 1.80
86 (30)1.28 to 1.47
95 (35)1.00 to 1.22
104 (40)0.80 to 1.00
113 (45)0.65 to 0.85
122 (50)0.50 to 0.70
131 (55)0.44 to 0.60
140 (60)0.36 to 0.50
Inspection
Procedure
Resistance
kW
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
32
(0)68
(20)104
(40)140
(60)
Temperature 5F (5C) Max
Min
Page 829 of 969
SENSOR INSPECTION FOR AIR CONDITIONING SYSTEM ± AC005-04 December 16, 2004
Page 3 of 12
2. Inspect Ambient
Temperature Sensor.
A. Measure the sensor resistance
according to the selected graph
(specification).
Resistance Value at 775F
(255C)1700 +/± 85W
NOTE:
Even slightly touching the sensor
may change the resistance value.
Be sure to hold the connector of
the sensor.
When measuring, the sensor
temperature must be the same as
the ambient temperature.
HINT:
As the temperature increases, the
resistance decreases.
TEMPERATURE 5F (5C)SPECIFICATION kW
50 (10)3.00 to 3.73
59 (15)2.45 to 2.88
68 (20)1.95 to 2.30
77 (25)1.60 to 1.80
86 (30)1.28 to 1.47
95 (35)1.00 to 1.22
104 (40)0.80 to 1.00
113 (45)0.65 to 0.85
122 (50)0.50 to 0.70
131 (55)0.44 to 0.60
140 (60)0.36 to 0.50
Inspection
Procedure
(Continued)
Resistance
kW
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
32
(0)68
(20)104
(40)140
(60)
Temperature 5F (5C) Max
Min
Page 830 of 969
SENSOR INSPECTION FOR AIR CONDITIONING SYSTEM ± AC005-04 December 16, 2004
Page 4 of 12
3. Inspect Air Duct Sensor.
A. Measure the sensor resistance
according to the table and
graph (specification).
NOTE:
Even slightly touching the sensor
may change the resistance value.
Be sure to hold the connector of
the sensor.
When measuring, the sensor
temperature must be the same as
the ambient temperature.
HINT:
As the temperature increases, the
resistance decreases.
TEMPERATURE 5F (5C)SPECIFICATION kW
50 (10)9.48 to 10.49
59 (15)7.50 to 8.28
68 (20)5.95 to 6.57
77 (25)4.77 to 5.25
86 (30)3.85 to 4.21
95 (35)3.12 to 3.40
104 (40)2.53 to 2.79
113 (45)2.06 to 2.30
122 (50)1.69 to 1.91
131 (55)1.39 to 1.59
140 (60)1.15 to 1.33
Inspection
Procedure
(Continued)
Resistance
kW
15.0
10.0
5.0
0.0
32
(0)68
(20)104
(40)140
(60)
Temperature 5F (5C) Max
Min
176
(80)
Page 832 of 969