190SI-01
- STARTING & CHARGINGCHARGING SYSTEM (3MZ-FE)
19-15
2347 Author: Date:
2005 LEXUS ES330 REPAIR MANUAL (RM1124U)
CHARGING SYSTEM (3MZ-FE)
PRECAUTION
1. SYSTEM INITIALIZATION
NOTICE:
When disconnecting the negative (-) battery terminal, initialize the following systems after the termi-
nal is reconnected.
System NameSee Page
Power Window Control System05-1470
Sliding Roof System74-8
2. Check that the battery cables are connected to the correct terminals.
3. Disconnect the battery cables if a quick charge is given to the battery.
4. Do not perform tests with a high voltage insulation resistance tester.
5. Never disconnect the battery while the engine is running.
6. Check that the charging cable is tightened on terminal B of the generator and the fuse box.
7. Do not check whether the alternator generates current or not with terminal F connected to the
other terminals.