Page 388 of 3502

ATC-10
PRECAUTIONS
VQ Engine
CAUTION:
The new and former refrigerant connections use different O-ring configurations. Never confuse O-
rings since they are not interchangeable. If a wrong O-ring is installed, refrigerant may leak at the con-
nection.
O-Ring Part Numbers and Specifications
WARNING:
Make sure all refrigerant is discharged into the recycling equipment and the pressure in the system is
less than atmospheric pressure. Then gradually loosen the discharge side hose fitting and remove it.
SJIA1646E
Connection type Piping connection point Part number QTY O-ring size
NewLow-pressure pipe 1 to low-pressure pipe 2 (One-touch joint) 92473 N8221 2 16
Low-pressure pipe 2 to expansion valve 92473 N8210 1 16
High-pressure pipe 1 to high-pressure pipe 2 (One-touch joint) 92471 N8221 2 8
High-pressure pipe 2 to expansion valve 92471 N8210 1 8
Condenser to high-pressure flexible hose 92472 N8210 1 12
Condenser to high-pressure pipe 1 92471 N8210 1 8
Low-pressure flexible hose to low-pressure pipe 1 (VQ engine) 92473 N8210 1 16
Compressor to low-pressure flexible hose 92474 N8210 1 19
Compressor to high-pressure flexible hose 92472 N8210 1 12
Liquid tank to condenser pipeInlet
92471 N82101
8
Outlet 1
FormerRefrigerant pressure sensor to condenser J2476 89956 1 10
Expansion valve to evaporatorInlet 92475 71L00 1 12
Outlet 92475 72L00 1 16
Page 436 of 3502

ATC-58
TROUBLE DIAGNOSIS
1. CHECK POWER SUPPLY CIRCUIT FOR UNIFIED METER AND A/C AMP.
1. Disconnect unified meter and A/C amp. connector.
2. Check voltage between unified meter and A/C amp. harness
connector M42 terminals 21, 22 and 35, unified meter and A/C
amp. harness connector M45 terminal 46 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check 10A and 15A fuses [Nos. 6, 10, 11, 12 and 19, located in the fuse block (J/B)]. Refer to PG-
79, "FUSE BLOCK - JUNCTION BOX (J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace if necessary.
If fuses are NG, harness for short circuit and replace fuse.
2. CHECK GROUND CIRCUIT FOR UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Check continuity between unified meter and A/C amp. harness
connector M42 terminal 29, 30 and ground.
OK or NG
OK >> Replace unified meter and A/C amp.
NG >> Repair harness or connector.
Terminals Ignition switch position
(+)
(-) OFF ACC ON Unified
meter and
A/C amp.
connectorTerminal No.
M42 21
GroundBattery volt-
ageBattery volt-
ageBattery
voltage
M42 22 Approx. 0 V Approx. 0 VBattery
voltage
M42 35 Approx. 0 VBattery volt-
ageBattery
voltage
M45 46 Approx. 0 V Approx. 0 VBattery
voltage
RJIA1984E
29, 30 – Ground : Continuity should exist.
RJIA1985E
Page 453 of 3502

TROUBLE DIAGNOSIS
ATC-75
C
D
E
F
G
H
I
K
L
MA
B
AT C
1. CHECK POWER SUPPLY FOR BLOWER MOTOR
1. Disconnect blower motor connector.
2. Turn ignition switch ON.
3. Check voltage between blower motor harness connector M48
terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check power supply circuit and 15A fuses [Nos. 10 and
11, located in the fuse block (J/B)]. Refer to PG-79,
"FUSE BLOCK - JUNCTION BOX (J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace if necessary.
If fuses are NG, check harness for short circuit and replace fuse.
2. CHECK FAN FEEDBACK CIRCUIT
1. Turn ignition switch OFF.
2. Reconnect blower motor connector.
3. Turn ignition switch ON.
4. Check voltage between unified meter and A/C amp. harness
connector M45 terminal 47 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 9.
3. CHECK BLOWER MOTOR
Check blower motor. Refer to AT C - 7 7 , "
Blower Motor" .
OK or NG
OK >> GO TO 4.
NG >> Replace blower motor.
4. CHECK POWER SUPPLY FOR FAN CONTROL AMP.
1. Turn ignition switch ON.
2. Check voltage between fan control amp. harness connector
M86 terminal 3 and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.1 – Ground : Battery voltage
RJIA2860E
47 – Ground : Battery voltage.
RJIA3266E
Terminals
Condition Voltage (+)
(−)
Fan control
amp. connectorTe r m i n a l N o .
M86 3 GroundFan speed: 1st
speedApprox. 8 V
RJIA2862E
Page 457 of 3502

TROUBLE DIAGNOSIS
ATC-79
C
D
E
F
G
H
I
K
L
MA
B
AT C
SYSTEM DESCRIPTION
Unified meter and A/C amp. controls compressor operation by intake air temperature and signal from ECM.
Low Temperature Protection Control
Unified meter and A/C amp. will turn the compressor ON or OFF as determined by a signal detected by intake
sensor.
When intake air temperature is higher than 4°C (39°F), the compres-
sor turns ON. The compressor turns OFF when intake air tempera-
ture is lower than 2.5°C (37°F).
DIAGNOSIS PROCEDURE FOR MAGNET CLUTCH
SYMPTOM: Magnet clutch does not engage when A/C switch is ON.
1. CHECK INTAKE SENSOR CIRCUIT
Check intake sensor. Refer to AT C - 4 7 , "
FUNCTION CONFIRMATION PROCEDURE" , see No. 11.
OK or NG
OK >> GO TO 2.
NG >> Malfunctioning intake sensor: Refer to ATC-105, "
Intake Sensor Circuit" .
2. PERFORM AUTO ACTIVE TEST
Refer to PG-21, "
Auto Active Test" .
Does the magnet clutch operate?
YES >>WITH CONSULT-II: GO TO 5.
WITHOUT CONSULT-II: GO TO 6.
NO >> Check 10 A fuse (No. 79, located in IPDM E/R). Refer to PG-25, "
IPDM E/R Terminal Arrange-
ment" , and GO TO 3.
RHA094GD
PJIA0011E
Page 544 of 3502
AV-16
AUDIO (WITH INTEGRATED DISPLAY SYSTEM)
4. Remove screws (2) and remove unified meter and A/C amp.
from bracket.
5. Remove screws (2) and remove audio unit with bracket.
6. Remove screws (4) and remove bracket.
CAUTION:
Be careful not to allow foreign material to enter from CD
slot.
INSTALLATION
Note the following, and installation is the reverse order of removal.
CAUTION:
Unified meter and A/C amp. screws (2) are different from other securing screws. Never confuse them
when installing.
Removal and Installation of Front Door SpeakerBKS00211
REMOVAL
1. Remove front door finisher. Refer to EI-35, "DOOR FINISHER" .
2. Remove screws (3) and remove front door speaker.
INSTALLATION
Installation is the reverse order of removal.
SKIB0876E
SKIB0877E
SKIA6297E
SKIB0882E
Page 563 of 3502
AUDIO (WITH INTEGRATED COLOR DISPLAY SYSTEM)
AV-35
C
D
E
F
G
H
I
J
L
MA
B
AV
4. Remove screws (4) and remove display control unit from
bracket.
5. Remove screws (2) and remove unified meter and A/C amp.
from bracket.
6. Remove screws (2) and remove audio unit with bracket.
7. Remove screws (4) and remove bracket.
CAUTION:
Be careful not to allow foreign material to enter from CD
slot.
INSTALLATION
Note the following, and installation is the reverse order of removal.
CAUTION:
Unified meter and A/C amp. screws (2) are different from other securing screws. Never confuse them
when installing.
SKIB0875E
SKIB0876E
SKIB0877E
SKIA6297E
Page 657 of 3502

BCM (BODY CONTROL MODULE)
BCS-15
C
D
E
F
G
H
I
J
L
MA
B
BCS
Check BCM Power Supply and Ground CircuitBKS001UJ
1. CHECK FUSES AND FUSIBLE LINK
Check for blown fuses and fusible link.
Refer to PG-3, "POWER SUPPLY ROUTING CIRCUIT" .
Refer to LT- 11 , "Wiring Diagram — H/LAMP —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse or fusible link is blown, be sure to eliminate cause of malfunction before installing new fuse
or fusible link. Refer to PG-3, "
POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
OK or NG
OK >> INSPECTION END
NG >> Check ground circuit harness.
Unit Power source Fuse and fusible link No.
BCMBatteryM
17
Ignition switch ON or START position 1
Ignition switch ACC or ON position 6
Terminals Ignition switch position
(+)
(–) OFF ACC ON
Connector Terminal
M311
GroundApprox. 0 VBattery
voltageBattery
voltage
38 Approx. 0 V Approx. 0 VBattery
voltage
M442 Battery
voltageBattery
voltageBattery
voltage
55 Battery
voltageBattery
voltageBattery
voltage
PKIA5204E
Connector Terminal
GroundContinuity
M4 52 Yes
PKIA6256E
Page 680 of 3502

BL-22
POWER DOOR LOCK SYSTEM
System DescriptionBIS000VW
Power is supplied at all times
through 50A fusible link (letter M , located in the fuse and fusible link box)
to BCM terminal 55.
through 15A fuse [No. 17, located in the fuse block (J/B)]
to BCM terminal 42.
to key switch terminal 1 (without intelligent key system)
through 15A fuse [No. 18, located in the fuse block (J/B)]
to key switch terminal 3 (with intelligent key system)
When key switch is ON (key is inserted in ignition key cylinder), power is supplied
through key switch terminal 4 (without intelligent key system) or 8 (with intelligent key system)
to BCM terminal 37.
Ground is supplied
to BCM terminal 52
through body grounds M71 and M72.
to power window main switch (door lock and unlock switch) terminal 17
through body grounds M71 and M72.
to front door lock assembly (driver side) (door unlock sensor) terminal 5
through body grounds M71 and M72.
LOCK OPERATION
When the door is locked with power window main switch (door lock and unlock switch)
Ground is supplied
to BCM terminal 60
through power window main switch (door lock and unlock switch) terminal 18
through power window main switch (door lock and unlock switch) terminal 17
through body grounds M71 and M72.
When the driver side door locked with hand or key cylinder
Ground is intercepted
to BCM terminal 7.
When you meet either the above-mentioned
Power is supplied
through BCM terminal 50
to each door lock actuators terminal 3
Ground is supplied
to each door lock actuators terminal 2
through BCM terminal 51.
Each door lock actuator locks the door lock.
UNLOCK OPERATION
When the door is unlocked with power window main switch (door lock and unlock switch)
Ground is supplied
to BCM terminal 61
through power window main switch (door lock and unlock switch) terminal 6
through power window main switch (door lock and unlock switch) terminal 17
through body grounds M71 and M72.
When the driver side door unlocked with hand or key cylinder
Ground is supplied
to BCM terminal 7
through front door lock assembly (driver side) (door unlock sensor) terminal 4
through front door lock assembly (driver side) (door unlock sensor) terminal 5