DI±358
± DIAGNOSTICSENGINE
552 Author: Date:
2005 SEQUOIA (RM1146U)
DTC P2111 Throttle Actuator Control System
±Stuck Open
DTC P2112 Throttle Actuator Control System
±Stuck Closed
CIRCUIT DESCRIPTION
The throttle motor is operated by the ECM. It opens and closes the throttle valve using gears. The opening
angle of the throttle valve is detected by the throttle position sensor, which is mounted on the throttle body.
The throttle position sensor provides feedback to the ECM to control the throttle motor and set the throttle
valve angle in response to driver input.
HINT:
This Electrical Throttle Control System (ETCS) does not use a throttle cable.
DTC No.DTC Detection ConditionTrouble Area
P2111Throttle motor locked during ECM order to close.
(1 trip detection logic)Throttle control motor and sensor circuit
Throttle control motor and sensor
P2112Throttle motor locked during ECM order to open.
(1 trip detection logic)
Throttle control motor and sensor
Throttle body
Throttle valve
MONITOR DESCRIPTION
The ECM concludes that there is a malfunction of the ETCS (Electronic Throttle Control System) when the
throttle valve remains at a fixed angle despite high drive current from the ECM. The ECM will turn on the MIL
and a DTC is set.
FAIL SAFE
If the ETCS (Electronic Throttle Control System) has a malfunction, the ECM cuts off current to the throttle
control motor. The throttle control valve returns to a predetermined opening angle (approximately 16°) by
the force of the return spring. The ECM then adjusts the engine output by controlling the fuel infection (inter-
mittent fuel±cut) and ignition timing in accordance with the accelerator pedal opening angle to enable the
vehicle to continue at a minimum speed.
If the accelerator pedal is depressed firmly and slowly, the vehicle can be driven slowly.
If a ºpassº condition is detected and then the ignition switch is turned OFF, the fail±safe operation will stop
and the system will return to normal condition.
DICFA±02
± DIAGNOSTICSENGINE
DI±359
553 Author: Date:
2005 SEQUOIA (RM1146U)
MONITOR STRATEGY
RltdDTCP2111Throttle motor actuator lock (Open)Related DTCsP2112Throttle motor actuator lock (Closed)
Rid / tMain sensors/componentsThrottle actuator motorRequired sensors/componentsRelated sensors/componentsThrottle position sensor
Frequency of operationContinuous
Duration0.5 sec.
MIL operationImmediate
Sequence of operationNone
TYPICAL ENABLING CONDITIONS
ItSpecificationItemMinimumMaximum
The monitor will run whenever these
DTCs are not presentSee page DI±18
P2111:
Throttle motor current2 A±
Throttle motor duty to close side80%±
P2112:
Throttle motor current2 A±
Throttle motor duty to open side80%±
TYPICAL MALFUNCTION THRESHOLDS
Detection CriteriaThreshold
|Current throttle position sensor voltage at this time ± throttle
position sensor voltage 0.016 sec. earlier|Less than 0.1 V when throttle motor open (or close) duty 80% or more
WIRING DIAGRAM
Refer to DTC P0120 on page DI±127.
INSPECTION PROCEDURE
HINT:
Read freeze frame data using the hand-held tester. Freeze frame data records the engine conditions when
a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was
running or stopped, if the engine was warmed up or not, if the air±fuel ratio was lean or rich, as well as other
data from the time when a malfunction occurred.
± DIAGNOSTICSENGINE
DI±363
557 Author: Date:
2005 SEQUOIA (RM1146U)
FAIL SAFE
If the ETCS (Electronic Throttle Control System) has a malfunction, the ECM cuts off current to the throttle
control motor. The throttle control valve returns to a predetermined opening angle (approximately 16°) by
the force of the return spring. The ECM then adjusts the engine output by controlling the fuel infection (inter-
mittent fuel±cut) and ignition timing in accordance with the accelerator pedal opening angle to enable the
vehicle to continue at a minimum speed.
If the accelerator pedal is depressed firmly and slowly, the vehicle can be driven slowly.
If a ºpassº condition is detected and then the ignition switch is turned OFF, the fail±safe operation will stop
and the system will return to normal condition.
MONITOR STRATEGY
Related DTCsP2118Throttle actuator motor power supply line range
check (Low voltage)
Required sensors/componentsThrottle actuator motor
Frequency of operationContinuous
Duration0.8 sec.
MIL operationImmediate
Sequence of operationNone
TYPICAL ENABLING CONDITIONS
ItSpecificationItemMinimumMaximum
The monitor will run whenever this DTC is
not presentSee page DI±18
Actuator powerON
Battery voltage8 V±
TYPICAL MALFUNCTION THRESHOLDS
Detection CriteriaThreshold
Throttle actuator motor power supply voltageLess than 4 V
COMPONENT OPERATING RANGE
ParameterStandard Value
Throttle actuator motor power supply voltage9 to 14 V
A21380
Engine Room J/B
ETCS
Fuse
B17411
+BM (+) E6
E4
E1 (±)
± DIAGNOSTICSENGINE
DI±365
559 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
HINT:
Read freeze frame data using the hand-held tester. Freeze frame data records the engine conditions when
a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was
running or stopped, if the engine was warmed up or not, if the air±fuel ratio was lean or rich, as well as other
data from the time when a malfunction occurred.
1 Check ETCS fuse.
PREPARATION:
Remove the ETCS fuse from the engine room J/B.
CHECK:
Check the resistance of the ETCS fuse.
OK:
Below 1 W
NG Check for short in all harness and components
connected to ETCS fuse.
OK
2 Check voltage between terminal +BM and E1 of ECM connector.
CHECK:
Measure the voltage between the specified terminals of the E6
and E4 ECM connector.
OK:
Standard:
Tester ConnectionSpecified Condition
+BM (E4±7) ± E6 (E6±1)9 to 14 V
OK Check for intermittent problems
(See page DI±11).
NG
± DIAGNOSTICSENGINE
DI±367
561 Author: Date:
2005 SEQUOIA (RM1146U)
DTC P2119 Throttle Actuator Control Throttle Body
Range/Performance
CIRCUIT DESCRIPTION
The Electric Throttle Control System (ETCS) is composed of a throttle motor that operates the throttle valve,
a throttle position sensor that detects the opening angle of the throttle valve, an accelerator pedal position
sensor that detects the accelerator pedal position, and the ECM that controls the ETCS system.
The ECM operates the throttle motor to position the throttle valve for proper response to driver inputs. The
throttle position sensor, mounted on the throttle body, detects the opening angle of the throttle valve and
provides this signal to the ECM so that the ECM can regulate the throttle motor.
DTC No.DTC Detection ConditionTrouble Area
P2119
Throttle opening angle continues to vary greatly from target
throttle opening angle
(1 trip detection logic)Electric throttle control system
Throttle body
MONITOR DESCRIPTION
The ECM determines the ºactualº throttle angle based on the throttle position sensor signal. The ºactualº
throttle position is compared to the ºtargetº throttle position commanded by the ECM. If the difference of
these two values exceeds a specified limit, the ECM interprets this as a fault in the ETCS (Electronic Throttle
Control System). The ECM turns on the MIL and a DTC is set.
FAIL SAFE
If the ETCS (Electronic Throttle Control System) has a malfunction, the ECM cuts off current to the throttle
control motor. The throttle control valve returns to a predetermined opening angle (approximately 16°) by
the force of the return spring. The ECM then adjusts the engine output by controlling the fuel infection (inter-
mittent fuel±cut) and ignition timing in accordance with the accelerator pedal opening angle to enable the
vehicle to continue at a minimum speed.
If the accelerator pedal is depressed firmly and slowly, the vehicle can be driven slowly.
If a ºpassº condition is detected and then the ignition switch is turned OFF, the fail±safe operation will stop
and the system will return to normal condition.
MONITOR STRATEGY
Related DTCsP2119Electronic throttle control system failure
Rid / tMain sensorsThrottle actuator motorRequired sensors/componentsRelated sensorsThrottle position sensor
Frequency of operationContinuous
Duration1 sec.
MIL operationImmediate
Sequence of operationNone
TYPICAL ENABLING CONDITIONS
The monitor will run whenever this DTC is
not presentSee page DI±18
The typical enabling condition is not avail-
able±
DICFC±02
DI±368
± DIAGNOSTICSENGINE
562 Author: Date:
2005 SEQUOIA (RM1146U)
TYPICAL MALFUNCTION THRESHOLDS
Detection CriteriaThreshold
Difference between ºtarget throttle positionº and ºactual
throttle positionº0.3 V or more
COMPONENT OPERATING RANGE
Standard Value
Commanded throttle position and current throttle position are nearly the same
WIRING DIAGRAM
Refer to DTC P2102 and P2103 on page DI±354.
INSPECTION PROCEDURE
HINT:
Read freeze frame data using the hand-held tester. Freeze frame data records the engine conditions when
a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was
running or stopped, if the engine was warmed up or not, if the air±fuel ratio was lean or rich, as well as other
data from the time when a malfunction occurred.
1 Are there any other codes (besides DTC P2119) being output?
PREPARATION:
(a) Connect the hand±held tester to the DLC3.
(b) Turn the ignition switch ON and push the hand±held tester main switch ON.
(c) When using hand±held tester, enter the following menu: DIAGNOSIS / ENHANCED OBD II / DTC
INFO / CURRENT CODES.
CHECK:
Read the DTC using the hand±held tester.
RESULT:
Display (DTC Output)Proceed to
P2119A
ºP2119º and other DTCB
HINT:
If any other codes besides P2119 are output, perform the troubleshooting for those DTCs first.
B Go to relevant DTC chart (See page DI±58).
A
FI7052DepressedReleased
DI±376
± DIAGNOSTICSENGINE
570 Author: Date:
2005 SEQUOIA (RM1146U)
INSPECTION PROCEDURE
HINT:
Read freeze frame data using the hand-held tester. Freeze frame data records the engine conditions when
a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was
running or stopped, if the engine was warmed up or not, if the air±fuel ratio was lean or rich, as well as other
data from the time when a malfunction occurred.
1 Connect hand±held tester, and read the voltage for accelerator pedal position
sensor data.
PREPARATION:
(a) Connect the hand±held tester to the DLC3.
(b) Turn the ignition switch ON and push the hand±held tes-
ter main switch ON.
(c) Enter the following menu: DIAGNOSIS / ENHANCED
OBD II / DATA LIST / ETCS / ACCEL POS #1 and ACCEL
POS #2.
CHECK:
Read the voltage for the accelerator pedal position sensor data.
OK:
Standard:
Accelerator pedalACCEL POS #1ACCEL POS #2
Released0.5 to 1.1 V1.2 to 2.0 V
Depressed2.6 to 4.5 V3.4 to 5.3 V
OK Go to step 5.
NG
FI7052DepressedReleased
± DIAGNOSTICSENGINE
DI±381
575 Author: Date:
2005 SEQUOIA (RM1146U)
TYPICAL ENABLING CONDITIONS
ItSpecificationItemMinimumMaximum
The monitor will run whenever this DTC is
not presentSee page DI±18
Either of the following conditions is metCondition 1 or 2
1. Ignition switchON
2. Throttle control motor powerON
TYPICAL MALFUNCTION THRESHOLDS
Detection CriteriaThreshold
Difference between VPA1 voltage (learned value) and VPA2
voltage (learned value)Less than 0.4 V, or more than 1.2 V
WIRING DIAGRAM
Refer to DTC P2120 on page DI±370.
INSPECTION PROCEDURE
HINT:
Read freeze frame data using the hand-held tester. Freeze frame data records the engine conditions when
a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was
running or stopped, if the engine was warmed up or not, if the air±fuel ratio was lean or rich, as well as other
data from the time when a malfunction occurred.
1 Connect hand±held tester, and read the voltage for accelerator pedal position
sensor data.
PREPARATION:
(a) Connect the hand±held tester to the DLC3.
(b) Turn the ignition switch ON and push the hand±held tes-
ter main switch ON.
(c) Enter the following menu: DIAGNOSIS / ENHANCED
OBD II / DATA LIST / ETCS / ACCEL POS #1 and ACCEL
POS #2.
CHECK:
Read the voltage for the accelerator pedal position sensor data.
OK:
Standard:
Accelerator pedalACCEL POS #1ACCEL POS #2
Released0.5 to 1.1 V1.2 to 2.0 V
Depressed2.6 to 4.5 V3.4 to 5.3 V
OK Replace ECM (See page SF±80).
NG