Page 1467 of 2395
KEY SWITCH (INSERT) CHECK=NBEL0115S07
1 CHECK KEY SWITCH INPUT SIGNAL
Check voltage between smart entrance control unit terminal 32 and ground.
SEL307X
Refer to wiring diagram in EL-274.
OK or NG
OK©Key switch is OK.
NG©GO TO 2.
2 CHECK KEY SWITCH (INSERT)
Check continuity between terminals 1 and 2.
SEL308X
OK or NG
OK©Check the following.
I7.5A fuse [No. 24, located in fuse block (J/B)]
IHarness for open or short between key switch and fuse
IHarness for open or short between smart entrance control unit and key switch
NG©Replace key switch.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-282
Page 1471 of 2395
4 CHECK POWER SUPPLY FOR MULTI-REMOTE CONTROL RELAY
1. Disconnect multi-remote control relay connector.
2. Check voltage between terminal 1 and ground.
SEL326X
OK or NG
OK©GO TO 5.
NG©Check the following.
I15A fuse [No. 20, located in fuse block (J/B)]
IHarness for open or short between multi-remote control relay and fuse
5 CHECK MULTI-REMOTE CONTROL RELAY CIRCUIT
1. Disconnect multi-remote control relay connector.
2. Check voltage between terminals 3 and 5.
3. Check voltage between terminals 6 and 7.
SEL327X
OK or NG
OK©Check harness for open or short between smart entrance control unit and multi-remote
control relay.
NG©Check the following.
IHarness for open or short between multi-remote control relay and fuse
IHarness for open or short between multi-remote control relay and turn signal lamps
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-286
Page 1480 of 2395

System DescriptionNBEL0120DESCRIPTIONNBEL0120S011. Operation FlowNBEL0120S0101
SEL334W
2. Setting The Theft Warning SystemNBEL0120S0102Initial condition
1) Close all doors.
2) Close hood and glass hatch.
Disarmed phase
When the theft warning system is in the disarmed phase, the security indicator lamp blinks every 2.6 seconds.
Pre-armed phase and armed phase
The theft warning system turns into the ªpre-armedº phase when hood, glass hatch and all doors are closed
and the doors are locked by key or multi-remote controller. (The security indicator lamp illuminates.)
After about 30 seconds, the system automatically shifts into the ªarmedº phase (the system is set). (The
security indicator lamp blinks every 2.6 seconds.)
3. Canceling The Set Theft Warning SystemNBEL0120S0103When the following 1) or 2) operation is performed, the armed phase is canceled.
1) Unlock the doors with the key or multi-remote controller.
2) Open the glass hatch with the key.
4. Activating The Alarm Operation of The Theft Warning SystemNBEL0120S0104Make sure the system is in the armed phase. (The security indicator lamp blinks every 2.6 seconds.)
When any of the following operations is performed, the system sounds the horns and flashes the headlamps
for about 50 seconds.
1) Engine hood, glass hatch or any door is opened before unlocking door with key or multi-remote control-
ler.
2) Door is unlocked without using key or multi-remote controller.
3) Disconnecting and connecting the battery connector before canceling armed phase.
POWER SUPPLY AND GROUNDNBEL0120S07Power is supplied at all times
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)]
Ito security indicator lamp terminal 1, and
Ito smart entrance control unit terminal 10.
With the ignition switch in the ON or START position, power is supplied
Ithrough 7.5A fuse [No. 11, located in the fuse block (J/B)]
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
THEFT WARNING SYSTEM
System Description
EL-295
Page 1481 of 2395
![INFINITI QX4 2001 Factory Service Manual Ito smart entrance control unit terminal 33.
With the ignition switch in the ACC or ON position, power is supplied
Ithrough 10A fuse [No. 10, located in the fuse block (J/B)]
Ito smart entrance contro INFINITI QX4 2001 Factory Service Manual Ito smart entrance control unit terminal 33.
With the ignition switch in the ACC or ON position, power is supplied
Ithrough 10A fuse [No. 10, located in the fuse block (J/B)]
Ito smart entrance contro](/manual-img/42/57027/w960_57027-1480.png)
Ito smart entrance control unit terminal 33.
With the ignition switch in the ACC or ON position, power is supplied
Ithrough 10A fuse [No. 10, located in the fuse block (J/B)]
Ito smart entrance control unit terminal 21.
Ground is supplied
Ito smart entrance control unit terminal 16
Ithrough body grounds M77 and M111.
INITIAL CONDITION TO ACTIVATE THE SYSTEMNBEL0120S02The operation of the theft warning system is controlled by the doors, hood and glass hatch.
To activate the theft warning system, the smart entrance control unit must receive signals indicating the doors,
hood and glass hatch are closed and the doors are locked.
When a door is open, smart entrance control unit terminal 28, 29 or 40 receives a ground signal from each
door switch.
When a door is unlocked, smart entrance control unit terminal 26, 36 or 37 receives a ground signal from ter-
minal 4 of each door unlock sensor or terminal 1 of back door unlock sensor.
When the hood is open, smart entrance control unit terminal 27 receives a ground signal
Ifrom terminal 1 of the hood switch
Ithrough body grounds E13 and E41.
When the glass hatch is open, smart entrance control unit terminal 38 receives a ground signal
Ifrom terminal 1 of the glass hatch switch
Ithrough body grounds D210, B11 and B22.
When the doors are locked with key or multi-remote controller and none of the described conditions exist, the
theft warning system will automatically shift to armed mode.
THEFT WARNING SYSTEM ACTIVATION (WITH KEY OR REMOTE CONTROLLER USED TO
LOCK DOORS)
NBEL0120S03If the key is used to lock doors, terminal 41 receives a ground signal
Ifrom terminal 3 of the key cylinder switch LH
Ithrough back grounds M77 and M111
Ifrom terminal 1 of the back door key cylinder switch
Ithrough body grounds B11, B22 and D210.
If this signal or lock signal from remote controller is received by the smart entrance control unit, the theft
warning system will activate automatically.
Once the theft warning system has been activated, smart entrance control unit terminal 31 supplies ground to
terminal 2 of the security indicator lamp.
The security lamp will illuminate for approximately 30 seconds and then blink.
Now the theft warning system is in armed phase.
THEFT WARNING SYSTEM ALARM OPERATIONNBEL0120S04The theft warning system is triggered by
Iopening a door
Iopening the hood or the glass hatch
Iunlocking door without using the key or multi-remote controller.
Once the theft warning system is in armed phase, if the smart entrance control unit receives a ground signal
at terminal 26, 36, 37 (door unlock sensor), 28, 29, 40 (door switch), 38 (glass hatch switch) or 27 (hood
switch), the theft warning system will be triggered. The headlamps flash and the horn sounds intermittently.
Power is supplied at all times
Ithrough 7.5A fuse (No. 52, located in fuse and fusible link box)
Ito horn relay terminals 1 and 3.
Ithrough 10A fuse (No. 54, located in fuse and fusible link box)
Ito horn relay terminal 6.
When the theft warning system is triggered, ground is supplied intermittently
Ifrom terminal 4 of the smart entrance control unit
Ito headlamp relay LH and RH terminal 2 and
Ifrom terminal 19 of the smart entrance control unit
THEFT WARNING SYSTEM
System Description (Cont'd)
EL-296
Page 1497 of 2395
SECURITY INDICATOR LAMP CHECK=NBEL0123S05
1 CHECK INDICATOR LAMP OUTPUT SIGNAL
1. Disconnect smart entrance control unit connector.
2. Check voltage between control unit terminal 31 and ground.
SEL341X
Refer to wiring diagram in EL-300.
OK or NG
OK©Security indicator lamp is OK.
NG©GO TO 2.
2 CHECK INDICATOR LAMP
OK or NG
OK©GO TO 3.
NG©Replace indicator lamp.
3 CHECK POWER SUPPLY CIRCUIT FOR INDICATOR LAMP
1. Disconnect security lamp connector.
2. Check voltage between indicator lamp terminal 1 and ground.
SEL342X
OK or NG
OK©Check harness for open or short between security indicator lamp and control unit.
NG©Check the following.
I7.5A fuse [No. 24, located in fuse block (J/B)]
IHarness for open or short between security indicator lamp and fuse
THEFT WARNING SYSTEM
Trouble Diagnoses (Cont'd)
EL-312
Page 1501 of 2395
HORN ALARM CHECK=NBEL0123S09
1 CHECK HORN ALARM OPERATION
1. Disconnect smart entrance control unit connector.
2. Apply ground to smart entrance control unit terminal 19.
SEL346X
Refer to wiring diagram in EL-304.
OK or NG
OK©Horn alarm is OK.
NG©GO TO 2.
2 CHECK HORN RELAY
Check horn relay.
OK or NG
OK©GO TO 3.
NG©Replace horn relay.
3 CHECK POWER SUPPLY FOR HORN RELAY
1. Disconnect horn relay connector.
2. Check voltage between terminal 2 and ground.
SEL347X
OK or NG
OK©GO TO 4.
NG©Check the following.
I7.5A fuse (No. 52, located in the fuse and fusible link box)
IHarness for open or short between horn relay and fuse
THEFT WARNING SYSTEM
Trouble Diagnoses (Cont'd)
EL-316
Page 1509 of 2395

Smart Entrance Control Unit Inspection TableNBEL0126
Terminal
No.Wire
colorConnections Operated conditionVoltage
(Approximate
values)
2 G/B Rear window defogger relay OFF,ON (Ignition key is in ªONº position) 0V,12V
4 PU/W Theft warning horn/lamp relay When panic alarm is operated using remote controller 12V,0V
5 R/YHeadlamp battery saver control
unitWhen headlamp battery saver timer is operated 12V
7 P Multi-remote control relay When doors are locked using remote controller 12V,0V
8 R/B Interior lampWhen interior lamp is operated using remote controller.
(Lamp switch in ªDOORº position)0V,12V
10 G/R Power source (Fuse) Ð 12V
11 W/R Power source (C/B) Ð 12V
13 W/PU Driver door lock actuator
Door lock & unlock switchFree 0V
14 Y/B Passenger door lock actuator Unlocked 12V
15 L Door lock actuators Door lock & unlock switchFree 0V
Locked 12V
16 B Ground Ð Ð
17 R/W Battery saver (Interior lamp) Battery saver is not operate,Operate 12V,0V
19 LG/B Horn relayWhen doors are locked using remote controller with horn
chirp mode.12V,0V
21 G/W Ignition switch (ACC) ªACCº position 12V
22 B/P Seat belt buckle switch Unfasten,Fasten (Ignition key is in ªONº position) 0V,12V
23 BR Door lock & unlock switches Neutral,Locks 5V,0V
26 Y/R Rear door unlock sensors All doors are locked,One or more doors are unlocked 5V,0V
27 Y/B Hood open signal ON (Open),OFF (Closed) 0V,5V
28 R/L Rear and back door switches OFF (Closed),ON (Open) 5V,0V
29 G/R Driver door switch OFF (Closed),ON (Open) 5V,0V
30 LG Door key cylinder unlock switch OFF (Neutral),ON (Unlocked) 12V,0V
31 BR/Y Theft warning indicator Goes off,Illuminates 12V,0V
32 W/R Ignition key switch (Insert) key inserted,key removed from IGN key cylinder 12V,0V
33 W/B Ignition switch (ON) Ignition key is in ªONº position 12V
35 LG/R Door lock & unlock switches Neutral,Unlocks 5V,0V
36 Y/G Driver door unlock sensor Driver door: Locked,Unlocked 5V,0V
37 Y/L Passenger door unlock sensor Passenger door: Locked,Unlocked 5V,0V
38 L/W Glass hatch switch ON (Open),OFF (Closed) 0V,12V
39 OR Rear window defogger switch OFF,ON 5V,0V
40 Y Passenger door switch OFF (Closed),ON (Open) 5V,0V
41 Y Door key cylinder lock switch OFF (Neutral),ON (Locked) 5V,0V
42 G/B Back door key unlock switch OFF (Neutral),ON (Unlock) 5V,0V
SMART ENTRANCE CONTROL UNIT
Smart Entrance Control Unit Inspection Table
EL-324
Page 1512 of 2395
4 CHECK GROUND CIRCUIT
Check continuity between terminal 2 and ground.
SEL359X
OK or NG
OK©Replace transmitter with sun visor assembly.
NG©Repair harness.
5 CHECK MAIN POWER SUPPLY FOR SMART ENTRANCE CONTROL UNIT
1. Disconnect smart entrance control unit.
2. Check voltage between smart entrance control unit terminal 10 and ground.
SEL360X
OK or NG
OK©GO TO 6.
NG©Check the following.
I7.5A fuse No. 24, located in fuse block (J/B)
6 CHECK GROUND CIRCUIT FOR SMART ENTRANCE CONTROL UNIT
Check continuity between terminal 16 and ground.
SEL361X
OK or NG
OK©Power supply and ground circuits are OK.
NG©Check ground harness.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
INTEGRATED HOMELINK TRANSMITTER
Trouble Diagnoses (Cont'd)
EL-327