CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
4 Turn the ignition off.
Install a known good relay in place of the park lamp relay.
Turn the Park Lamps On.
Do the Park Lamps operate normally?All
Ye s®Replace the Park Lam

Page 515 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
RIGHT FRONT TURN SIGNAL OUTPUT OPEN
When Monitored and Set Condition:
RIGHT FRONT TURN SIGNAL OUTPUT OPEN
When Monitored: Ignition On.
Set Condition: When the output voltage status is LOW.
PO

Page 516 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
3 Turn the ignition off.
Disconnect the Right Turn Signal Lamp connector.
Turn the ignition on.
Turn the Right Turn Signal on.
Using a 12-volt test light connected to ground,

Page 517 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
RIGHT FRONT TURN SIGNAL OUTPUT SHORT
When Monitored and Set Condition:
RIGHT FRONT TURN SIGNAL OUTPUT SHORT
When Monitored: Anytime the IPM is active.
Set Condition: When output voltage statu

Page 531 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
RIGHT REAR TURN SIGNAL OUTPUT OPEN
When Monitored and Set Condition:
RIGHT REAR TURN SIGNAL OUTPUT OPEN
When Monitored: Ignition On.
Set Condition: When output voltage status is LOW.
POSSIBLE

Page 532 of 4284

CHRYSLER VOYAGER 2001  Service Manual TEST ACTION APPLICABILITY
4 Turn the ignition off.
Disconnect the Body Control Module C2 connector.
Measure the resistance of the Right Rear Turn Signal Driver Circuit to ground.
Is the resistance abo

Page 533 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
RIGHT REAR TURN SIGNAL OUTPUT SHORT
When Monitored and Set Condition:
RIGHT REAR TURN SIGNAL OUTPUT SHORT
When Monitored: Anytime the BCM is active.
Set Condition: When output voltage status

Page 535 of 4284

CHRYSLER VOYAGER 2001  Service Manual Symptom:
RIGHT SIDE PARK LAMP OPEN
When Monitored and Set Condition:
RIGHT SIDE PARK LAMP OPEN
When Monitored: Anytime the FCM is active.
Set Condition: When B+ voltage is below 10.0 volts.
POSSIBLE C