S05389
Circuit Opening
RelaySF0DY±03
S04970
Continuity
Ohmmeter
1
35 2Ohmmeter
No Continuity
S04969ContinuityOhmmeter
1
35 2
Battery
± SFI (5S±FE)CIRCUIT OPENING RELAY
SF±41
1474 Author: Date:
CIRCUIT OPENING RELAY
INSPECTION
1. REMOVE RELAY BOX COVER
2. REMOVE CIRCUIT OPENING RELAY (Marking: CIR
OPN)
3. INSPECT CIRCUIT OPENING RELAY
(a) Inspect the relay continuity.
(1) Using an ohmmeter, check that there is continuity
between terminals 1 and 2.
If there is no continuity, replace the relay.
(2) Check that there is no continuity between terminals
3 and 5.
If there is continuity, replace the relay.
(b) Inspect the relay operation.
(1) Apply battery positive voltage across terminals 1
and 2.
(2) Using an ohmmeter, check that there is continuity
between terminals 3 and 5.
If there is no continuity, replace the relay.
4. REINSTALL CIRCUIT OPENING RELAY
5. REINSTALL RELAY BOX COVER
S05389
Circuit Opening
RelaySF089±03
S04970
Ohmmeter OhmmeterContinuity
No Continuity 12
5
3
S04969
Ohmmeter
Continuity 12
5
3
Battery SF±54
± SFI (1MZ±FE)CIRCUIT OPENING RELAY
1553 Author: Date:
CIRCUIT OPENING RELAY
INSPECTION
1. REMOVE RELAY BOX COVER
2. REMOVE CIRCUIT OPENING RELAY
(Marking: CIR OPN)
3. INSPECT CIRCUIT OPENING RELAY CONTINUITY
(a) Using an ohmmeter, check that there is continuity be-
tween terminals 1 and 2.
If there is no continuity, replace the relay.
(b) Check that there is no continuity between terminals 3 and
5.
If there is continuity, replace the relay.
4. INSPECT CIRCUIT OPENING RELAY OPERATION
(a) Apply battery positive voltage across terminals 1 and 2.
(b) Using an ohmmeter, check that there is continuity be-
tween terminals 3 and 5.
If there is no continuity, replace the relay.
5. REINSTALL CIRCUIT OPENING RELAY
6. REINSTALL RELAY BOX COVER