Page 1109 of 1285

DODGE NEON 2000  Service Repair Manual Pending ConditionsÐThere are not conditions
or situations that prompt conflict or suspension of
testing. The oxygen sensor heater test is not run
pending resolution of MIL illumination due to oxygen

Page 1110 of 1285

DODGE NEON 2000  Service Repair Manual Pending ConditionsÐ
²Misfire DTC
²Front Oxygen Sensor Response
²Front Oxygen Sensor Heater Monitor
²Front Oxygen Sensor Electrical
²Rear Oxygen Sensor Rationality (middle check)
²Rear Oxygen Se

Page 1127 of 1285

DODGE NEON 2000  Service Repair Manual (3) Remove seat back.
(4) Remove track and recliner assembly.
(5) Remove seat cushion (Fig. 5).
INSTALLATION
(1) Connect seat cushion heater element connector,
if equipped.
(2) Install track and recli

Page 1135 of 1285

DODGE NEON 2000  Service Repair Manual DIAGNOSIS AND TESTING
WATER LEAKS
Water leaks can be caused by poor sealing,
improper body component alignment, body seam
porosity, missing plugs, or blocked drain holes. Cen-
trifugal and gravitation

Page 1232 of 1285

DODGE NEON 2000  Service Repair Manual HEATING AND AIR CONDITIONING
TABLE OF CONTENTS
page page
GENERAL INFORMATION
A/C APPLICATION TABLE...................2
HEATER AND AIR CONDITIONING CONTROL...2
HEATER AND AIR CONDITIONING............2

Page 1233 of 1285

DODGE NEON 2000  Service Repair Manual GENERAL INFORMATION
A/C APPLICATION TABLE
Item Description Notes
Vehicle PL Neon
System expansion valve
Total Refrigerant
CapacityR134a 765 grams / 27 oz / 1.69 lbs
Total Oil Capacity ND-8 PAG oil 180

Page 1234 of 1285

DODGE NEON 2000  Service Repair Manual It is also important to keep the air intake openings
clear of debris because leaf particles and other debris
that is small enough to pass through the cowl ple-
num screen can accumulate within the hea

Page 1237 of 1285

DODGE NEON 2000  Service Repair Manual COMPRESSOR FRONT SHAFT SEAL
The compressor front shaft seal is not serviceable.
If a leak is detected at the shaft seal, the compressor
must be replaced as a unit.
CONDENSATION DRAIN TUBE
Condensation