Page 704 of 4592

Will you register the
next key?
No Ye s
Insert already registered master key in the key
cylinder
Depress and release the acceleration pedal 4
times.
Depress and release the brake pedal 5 times,
and remove the master key.
Insert key to be registered in key cylinder.
Depress and release the acceleration pedal 1
time. (Security indicator blinks)
The registration mode completes when pulling
out the key within 10sec. and the brake pedal is
depressed or after indicator is off 10 sec. pass. Within 10 sec.Within 15 sec.
Within 20 sec.
Within 10 sec.
Within 10 sec.
After 60 sec. additional sub±key is registered.
(Security indicator is OFF)
± BODY ELECTRICALENGINE IMMOBILISER SYSTEM
BE±123
2343 Author: Date:
3. REGISTRATION ADDITIONAL OF SUB±KEY
There are 2 ways for registration of additional sub±key, one is depressing brake pedal and acceleration ped-
al and the other is using TOYOTA hand±held tester.
HINT:
It is possible top register up to 3 sub±key codes including the already registered key code.
When any operation time described below is over, registration mode completes.
When the next procedure is performed while the timer is working, the timer completes counting time,
then next timer starts.
(1) Depressing brake pedal and acceleration pedal:
Page 706 of 4592

1. Insert master key in the key cylinder.
2. Depress and release the acceleration pedal 6 times.
3. Depress and release the brake pedal 7 times.
(Security indicator blinks)
4. Remove the master key.
(Security indicator blinks)
HINT:
When the key cannot be pulled out in the step 4, key code deletion is canceled.
(Security indicator is OFF) END
(Key code erasured)
Within 15 sec.
Within 20 sec.
Within 10 sec.
± BODY ELECTRICALENGINE IMMOBILISER SYSTEM
BE±125
2345 Author: Date:
4. ERASURE OF TRANSPONDER KEY CODE
There are 2 ways for erasure of transponder key code, one is depressing brake pedal and acceleration pedal
and the other is using TOYOTA hand±held tester.
NOTICE:
All other master and sub±key codes are deleted leaving the master key code to use the operation.
When using the key which was used before deleting, it is necessary to register the code again.
HINT:
When any operation time described below is over, registration mode completes.
When the next procedure is performed while the timer is working, the timer completes counting time,
then next timer starts.
(1) Depressing brake pedal and acceleration pedal:
Page 707 of 4592
1. Insert master key in the key cylinder.
2. Require key code deletion from hand±held tester.
(Security indicator blinks)
3. Remove the master key.
HINT:
When the key cannot be pulled out in the step 3, key code deletion is canceled.
(Security indicator is OFF) END
(Key code erasured)
Within 120 sec.
Within 10 sec.
BE±126
± BODY ELECTRICALENGINE IMMOBILISER SYSTEM
2346 Author: Date:
(2) Using TOYOTA hand±held tester:
Page 805 of 4592
I00399
Plug (Main)Antenna
Terminal
(Main)
Plug (Sub)Antenna
Terminal
(Sub) (1)
(3)(2)
(4)
I00402
I00403N21548
I00407
Ground point:
Antenna Cord
Center Brace
Pillar (RH)
Pillar (LH) Choke Coil
± BODY ELECTRICALAUDIO SYSTEM
BE±89
2309 Author: Date:
5. Glass printed antenna:
GROUNDING FOR THE ANTENNA CORD AND CHOKE
COIL
HINT:
During troubleshooting, in case that the antenna code continu-
ity check, grounding check and grounding check of the choke
coil are needed, please check refering to the following illustra-
tion.
Terminal connectionNormal condition
(1) e (2)Continuity
(3) e (4)Continuity
Page 806 of 4592
I00400
PlugAntenna
Terminal
(1) (2)
I00427
I00428
I00429I00408
Ground point:
Antenna Cord
Center Brace Luggage Room (RH side)
Pillar (LH) Noise Filter BE±90
± BODY ELECTRICALAUDIO SYSTEM
2310 Author: Date:
6. Fixed mast antenna:
GROUNDING FOR THE ANTENNA CORD AND CHOKE
COIL
HINT:
During troubleshooting, in case that the antenna code continu-
ity check, grounding check and grounding check of the choke
coil are needed, please check refering to the following illustra-
tions.
Terminal connectionNormal condition
(1) e (2)Continuity
Page 835 of 4592
BE0B2±06
START
Insert the key in the key cylinder.
Under registration
Registration completion
Remove the key.
Will you register the
next key?
NoSecurity indicator blinks until the first
key is inserted. The indicator lights up
after the key registration.
Security Indicator ON
Security Indicator
OFF
END Ye s
Security Indicator ON
(After the last key (sub±key)
has been registered, the indi-
cator goes off.)
± BODY ELECTRICALENGINE IMMOBILISER SYSTEM
BE±119
2339 Author: Date:
ENGINE IMMOBILISER SYSTEM
REGISTRATION PROCEDURE
1. KEY REGISTRATION IN AUTOMATIC REGISTRATION MODE
(a) Registration of a new transponder key.
HINT:
This must be done when you have installed a new ECM.
The new ECM is in the automatic key code registration mode. The already fixed number of key codes
for this ECM can be registered.
On this type of vehicle, up to 4 key codes can be registered.
In the automatic registration mode, the last key registered becomes sub±key.
Page 836 of 4592

1.2 Sec.
0.8 Sec.
0.25 Sec. 0.5 Sec.0.25 Sec.
1 Sec. Blinks Code 2±1 Code2±2
0.25 Sec.
0.25 Sec.0.5 Sec. 1 Sec. BE±120
± BODY ELECTRICALENGINE IMMOBILISER SYSTEM
2340 Author: Date:
HINT:
When a key is not inserted in the key cylinder in the automatic registration mode, the security indicator
always lights on.
When the immobiliser system operations normally and the key is pull out, the security indicator blinks.
When key code registration could not be performed in the automatic registration mode, code 2±1 is
output from the security indicator and when inserting the already registered key, code 2±2 is output.
(b) Automatic registration mode completion
If completing the mode forcibly when more than 1 key code have been registered in the automatic reg-
istration mode, perform the following procedures.
After 1 more key code have been registered with master key, perform step (1) or (2) without pulling
the key out or inserting the already registered key.
(1) Depress and release brake pedal 5 times or more within 15sec.
(2) With the TOYOTA hand±held tester, require automatic registration mode completion.
Page 837 of 4592

Will you register the
next key?
No Ye s
Insert already registered master key in the key
cylinder
Depress and release the acceleration pedal 5
times.
Depress and release the brake pedal 6 times,
and remove the master key.
Insert key to be registered in key cylinder.
Depress and release the acceleration pedal 1
time. (Security indicator blinks)
The registration mode completes when pulling
out the key within 10sec. and the brake pedal is
depressed or after indicator is off 10 sec. pass. Within 10 sec.Within 15 sec.
Within 20 sec.
Within 10 sec.
Within 10 sec.
After 60 sec. additional master key is registered.
(Security indicator is OFF)
± BODY ELECTRICALENGINE IMMOBILISER SYSTEM
BE±121
2341 Author: Date:
2. REGISTRATION OF ADDITIONAL MASTER KEY
There are 2 ways for registration of additional master key, one is depressing brake pedal and acceleration
pedal and the other is using TOYOTA hand±held tester.
HINT:
It is possible to register up to 7 master key codes including the already registered key code.
When any operation time described below is over, registration mode completes.
When the next procedure is performed while the timer is working, the timer completes counting time,
then next timer starts.
(1) Depressing brake pedal and acceleration pedal: