SERVICE SPECIFICATIONS
SERVICE DATA
Thermostat
Valve opening temperature
Valve lift at 95°C (203°F)
80±84°C (176±183°F)
8.5 mm (0.335 in.) or more
Radiator cap
Relief valve opening pressure STD
Minimum
93±123 kPa
(0.95±1.25 kgf/cm2, 13.5±17.8 psi)
78 kPa (0.8 kgf/cm
2, 11.4 psi)
Electric
cooling fan
Rotating amperage
2.5±4.5 A
TORQUE SPECIFICATIONS
Part tightened NVm kgfVcm ftVlbf
Engine drain plug x Cylinder block 29 300 22
Fan x Fluid coupling 7.4 75 65 in.Vlbf
Water pump x Cylinder block 21 210 15
Water pump x No.2 water bypass pipe 21 210 15
Generator x Water pump 37 380 27
Generator x Cylinder block 37 380 27
Water bypass outlet x Cylinder head (2JZ±GE) 8.8 90 78 in.Vlbf
Water outlet x Cylinder head (2JZ±GTE) 21 210 15
Water inlet x Water pump (2JZ±GE) 8.8 90 78 in.Vlbf
Water inlet x Water pump (2JZ±GTE) 21 210 15 Upper radiator support x Body 15 155 11 ECT switch x Radiator (2JZ±GTE) 7.4 75 65 in.Vlbf Fluid coupling x Water pump 16 165 12 Oil cooler x Radiator lower tank (A/T) 8.3 85 74 in.Vlbf Oil cooler x Oil cooler pipe (A/T) 15 150 11
EG±358± ENGINECOOLING SYSTEM
TIMING BELT REMOVAL
1. REMOVE RADIATOR ASSEMBLY
(See radiator removal in Cooling System)
2. 2JZ±GTE M/T:
REMOVE DRIVE BELT TENSIONER DAMPER
Remove the 2 nuts and tensioner damper.
3. REMOVE DRIVE BELT, FAN, FLUID COUPLING
ASSEMBLY AND WATER PUMP PULLEY
(See step 6 in water pump removal in Cooling System)
4. REMOVE NO.3 TIMING BELT COVER
(a) Remove the oil filler cap.
(b) 2JZ±GE:
Using a 5 mm hexagon wrench, remove the 6 bolts and belt
cover.
(c) 2JZ±GTE:
Using a 5 mm hexagon wrench, remove the 10 bolts and belt
cover.
5. REMOVE NO.2 TIMING BELT COVER
Using a 5 mm hexagon wrench, remove the 3 bolts, belt cover
and gasket.
If you are unable to loosen the bolt on the right because the
PS pump pulley interferes with the hexagon wrench, first re-
move the pulley.
6. REMOVE DRIVE BELT TENSIONER
Remove the 3 bolts and tensioner. EG±24
± ENGINEENGINE MECHANICAL