CCS
DTC 96 NP RANGECCS-39
< COMPONENT DIAGNOSIS >
C
DE
F
G H
I
J
K L
M B
N P A
DTC 96 NP RANGE
DTC 96 NP RANGEINFOID:0000000005145996
Regarding Wiring Diagram information, refer to CCS-48, "Wiring Diagram".
1.CHECK ICC UNIT CONNECTORS
1. Turn ignition switch OFF.
2. Disconnect ICC unit harness connectors and connect them securely again. Erase DTC, then perform self- diagnosis of ICC system again.
Does the DTC reset?
YES >> GO TO 2
NO >> • Poor connector connection. • Check connector. Check connector housing for disconnected, loose, bent, and collapsed termi-nals. If any malfunction is detected, repair as necessary. Erase DTC and perform ICC system
running test. Refer to CCS-8, "
ACTION TEST : ICC System Running Test".
2.CHECK NP RANGE SWITCH SIGNAL
With data monitor, check that “NP RANGE SW” operates normally.
Does the "NP RANGE SW" monitor item operate normally?
YES >> Perform TCM diagnosis. Refer to TM-30, "Introduction".
NO >> GO TO 3
3.CHECK HARNESS BETWEEN ICC UNIT AND TCM
1. Turn ignition switch OFF.
2. Disconnect ICC unit harness connectors and A/T assembly har- ness connector.
3. Check continuity between ICC unit harness connector B13 ter- minal 7 and A/T assembly harness connector F9 terminal 9.
Does continuity exist?
YES >> Replace ICC unit. Refer to CCS-71, "ICC Unit". Erase
DTC and perform ICC system running test. Refer to
CCS-8, "
ACTION TEST : ICC System Running Test".
NO >> • Repair harness between ICC unit and TCM. • Erase DTC and perform ICC system running test. Refer to CCS-8, "
ACTION TEST : ICC Sys-
tem Running Test".
7 - 9 Continuity
should exist.
SKIA5982E
Revision: April 20092010 QX56
CCS-48
< ECU DIAGNOSIS >
ICC UNIT
Wiring Diagram
INFOID:0000000005146005
ABOWA0005GB
Revision: April 20092010 QX56
CHG
CHG-1
ELECTRICAL & POWER CONTROL
C
DE
F
G H
I
J
K L
B
SECTION CHG
A
O P
N
CONTENTS
CHARGING SYSTEM
PRECAUTION .......
........................................2
PRECAUTIONS .............................................. .....2
Precaution for Supplemental Restraint System
(SRS) "AIR BAG" and "SEAT BELT PRE-TEN-
SIONER" ............................................................. ......
2
Precaution Necessary for Steering Wheel Rota-
tion After Battery Disconnect ............................... ......
2
Precaution for Power Generation Variable Voltage
Control System ..........................................................
3
PREPARATION ............................................4
PREPARATION .............................................. .....4
Special Service Tool ........................................... ......4
Commercial Service Tool ..........................................4
BASIC INSPECTION ....................................5
DIAGNOSIS AND REPAIR WORKFLOW ..... .....5
Work Flow ........................................................... ......5
FUNCTION DIAGNOSIS ...............................6
CHARGING SYSTEM ..................................... .....6
System Diagram .................................................. ......6
System Description ...................................................6
Component Description ............................................6
POWER GENERATION VOLTAGE VARI-
ABLE CONTROL SYSTEM .................................
7
System Diagram .................................................. ......7
System Description ...................................................7
Component Description .............................................7
COMPONENT DIAGNOSIS ..........................8
CHARGING SYSTEM PRELIMINARY IN-
SPECTION ....... ..................................................
8
Inspection Procedure ........................................... .....8
POWER GENERATION VOLTAGE VARI-
ABLE CONTROL SYSTEM OPERATION IN-
SPECTION .........................................................
9
Diagnosis Procedure ........................................... .....9
B TERMINAL CIRCUIT .....................................11
Description ...............................................................11
Diagnosis Procedure ...............................................11
L TERMINAL CIRCUIT .....................................12
Description ...............................................................12
Diagnosis Procedure ...............................................12
S TERMINAL CIRCUIT .....................................13
Description ...............................................................13
Diagnosis Procedure ...............................................13
CHARGING SYSTEM .......................................14
Wiring Diagram ........................................................14
SYMPTOM DIAGNOSIS ..............................20
CHARGING SYSTEM .......................................20
Symptom Table ................................................... ....20
ON-VEHICLE REPAIR .................................21
GENERATOR ....................................................21
Removal and Installation ..................................... ....21
SERVICE DATA AND SPECIFICATIONS
(SDS) ............... .......................................... ...
22
GENERATOR ....................................................22
Generator ............................................................ ....22
Revision: April 20092010 QX56
CHG-6
< FUNCTION DIAGNOSIS >
CHARGING SYSTEM
FUNCTION DIAGNOSIS
CHARGING SYSTEM
System DiagramINFOID:0000000005146551
System DescriptionINFOID:0000000005146552
The generator provides DC voltage to operate the vehicle's electrical system and to keep the battery charged.
The voltage output is controlled by the IC regulator.
Component DescriptionINFOID:0000000005146553
ALMIA0207GB
Component part Description
Generator Terminal “1”
Refer to CHG-11, "
Description".
Terminal “2” Refer to CHG-12, "
Description".
Terminal “3” Refer to CHG-13, "
Description".
Terminal “4” Used for the power generation voltage variable control system.
Refer to
CHG-7, "
System Description".
Combination meter (C harge warning lamp) The IC regulator warning function activates to illuminate the
charge warning lamp if any of the following symptoms occur while
generator is operating:
• Excessive voltage is produced.
• No voltage is produced.
IPDM E/R Used for the power generation voltage variable control system.
Refer to
CHG-7, "
System Description".
Revision: April 20092010 QX56
CHG
POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM
CHG-7
< FUNCTION DIAGNOSIS >
C
D E
F
G H
I
J
K L
B A
O P
N
POWER GENERATION VOLTAG
E VARIABLE CONTROL SYSTEM
System DiagramINFOID:0000000005146554
System DescriptionINFOID:0000000005146555
Power generation variable voltage control system has been adopted. By varying the voltage to the generator,
engine load due to power generation of the generator is reduced and fuel consumption is decreased.
NOTE:
When any malfunction is detected in the power generat ion variable voltage control system, power generation
is performed according to the characterist ic of the IC regulator in the generator.
Component DescriptionINFOID:0000000005146556
ALMIA0057GB
Component part Description
Battery current sensor The battery current sensor is installed on the battery cable at the
negative terminal. The battery current sensor detects the charg-
ing/discharging current of the battery and sends a voltage signal
to the ECM according to the current value detected.
ECM The battery current sensor detects the charging/discharging cur-
rent of the battery. The ECM judges the battery condition based on
this signal.
The ECM judges whether to request more output via the power
generation voltage variable control according to the battery condi-
tion.
When performing the power generation voltage variable control,
the ECM calculates the target power generation voltage according
to the battery condition and sends the calculated value as the pow-
er generation command value to the IPDM E/R.
IPDM E/R The IPDM E/R converts the received power generation command
value into a pulse width modulated (PWM) command signal and
sends it to the IC regulator.
Generator (IC regulator) The IC regulator controls the power generation voltage by the tar-
get power generation voltage based on the received PWM com-
mand signal.
When there is no PWM command signal, the generator performs
the normal power generation according to the characteristic of the
IC regulator.
Revision: April 20092010 QX56
CHG
POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM OPERATION
INSPECTION
CHG-9
< COMPONENT DIAGNOSIS >
C
DE
F
G H
I
J
K L
B A
O P
N
POWER GENERATION VOLTAGE VARI
ABLE CONTROL SYSTEM OPER-
ATION INSPECTION
Diagnosis ProcedureINFOID:0000000005146558
Regarding Wiring Diagram information, refer to CHG-14, "Wiring Diagram".
CAUTION:
When performing this inspection, always use a charged battery that has completed the battery inspec-
tion. (When the charging rate of the battery is low, the response speed of the voltage change will
become slow. This can cause an incorrect inspection.)
1.CHECK ECM (CONSULT-III)
Perform ECM self-diagnosis with CONSULT-III. Refer to EC-63, "
CONSULT-III Function (ENGINE)".
Self
-diagnostic results content
No malfunction detected>> GO TO 2.
Malfunction detected>> Check applicable parts, and repair or replace corresponding parts.
2.CHECK OPERATION OF POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM
1. Connect CONSULT-III and start the engine.
2. The selector lever is in “P” or “N” position and a ll of the electric loads and A/C, etc. are turned OFF.
3. Select “ALTERNATOR DUTY” in “Active Test” of “ENGINE”, and then check the value of “BATTERY
VOLT” monitor when DUTY value of “ALTERNATOR DUTY” is set to 40.0 %.
4. Check the value of “BATTERY VOLT” monitor when DUTY value of “ALTERNATOR DUTY” is set to 80.0%.
Is the measurement val ue within specification?
YES >> Inspection End.
NO >> GO TO 3.
3.CHECK IPDM E/R (CONSULT-III)
Perform IPDM E/R self-diagnosis with CONSULT-III. Refer to PCS-14, "
CONSULT - III Function (IPDM E/R)".
Self
-diagnostic results content
No malfunction detected>> GO TO 4.
Malfunction detected>> Check applicable parts, and repair or replace corresponding parts.
4.CHECK HARNESS BETWEEN GE NERATOR AND IPDM E/R
“BATTERY VOLT”
2 seconds after setting the
DUTY value of “ALTERNA-
TOR DUTY” to 40.0 %
: 12 - 13.6 V
“BATTERY VOLT”
20 seconds after setting
the DUTY value of “ALTER-
NATOR DUTY” to 80.0 % : +0.5 V or more against
the value of “BATTERY
VOLT” monitor when
DUTY value is 40.0 %
Revision: April 20092010 QX56
CHG
B TERMINAL CIRCUITCHG-11
< COMPONENT DIAGNOSIS >
C
DE
F
G H
I
J
K L
B A
O P
N
B TERMINAL CIRCUIT
DescriptionINFOID:0000000005146559
The terminal “1” circuit supplies power to charge the battery and operate the vehicles electrical system.
Diagnosis ProcedureINFOID:0000000005146560
Regarding Wiring Diagram information, refer to
CHG-14, "Wiring Diagram".
1.CHECK TERMINAL “1” CONNECTION
1. Turn ignition switch OFF.
2. Verify terminal “1” is clean and tight.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair terminal “1” connection. Confirm repa ir by performing complete Starting/Charging system
test. Refer to diagnostic station instruction manual.
2.CHECK TERMINAL “1” CIRCUIT
Check voltage between generator connector E204 terminal 1 and
ground.
Is voltage reading as specified?
YES >> GO TO 3.
NO >> Check harness for open between generator and fusible link.
3.CHECK TERMINAL “1” CONNECTION (VOLTAGE DROP TEST)
1. Start engine, then engine running at idle and warm.
2. Check voltage between battery positive terminal and generator connector E204 terminal 1.
Is the voltage reading as specified?
YES >> Terminal “1” circuit is normal. Refer to CHG-5, "Work
Flow".
NO >> Check harness between battery and generator for high resistance.
(+) (-) Voltage
Connector Terminal
E204 1Ground Battery voltage
ALMIA0197ZZ
(+)
(-)Voltage
Connector Terminal
E204 1 Battery positive terminal Less than 0.2V
ALMIA0198ZZ
Revision: April 20092010 QX56
CHG-12
< COMPONENT DIAGNOSIS >
L TERMINAL CIRCUIT
L TERMINAL CIRCUIT
DescriptionINFOID:0000000005146561
The terminal “2” (L) circuit controls the charge warning lamp. The charge warning lamp illuminates when the
ignition switch is set to ON or START. When the generator is providing sufficient voltage with the engine run-
ning, the charge warning lamp will go off. If the c harge warning lamp illuminates with the engine running, a
malfunction is indicated.
Diagnosis ProcedureINFOID:0000000005146562
Regarding Wiring Diagram information, refer to CHG-14, "Wiring Diagram".
1.CHECK CHARGE WARNING LAMP CIRCUIT CONNECTION
Verify generator connector E205 terminal 2 is clean and tight.
Is the connection secure?
YES >> GO TO 2.
NO >> Repair the connection. Confirm repair by per forming complete Starting/Charging system test.
Refer to diagnostic station instruction manual.
2.CHECK CHARGE WARNING LAMP CIRCUIT
1. Disconnect generator connector E205.
2. Apply ground to generator harness connector E205 terminal 2 with the ignition switch in the ON position.
Does the charge lamp illuminate?
YES >> Check generator function. Refer to CHG-5, "Work Flow".
NO >> GO TO 3.
3.CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect the generator connector E205 and combination meter connector M24.
3. Check continuity between generator harness connector E205 (A) terminal 2 and combination meter harness connector M24
(B) terminal 6.
4. Check continuity between generator harness connector E205 (A) terminal 2 and ground.
Are the continuity results as specified?
YES >> Replace the combination meter. Refer to MWI-100, "Removal and Installation".
NO >> Repair the harness or connector. Charge lamp should illuminate
ALMIA0200ZZ
AB
Continuity
Connector Terminal Connector Terminal
E205 2M24 6Yes
A —
Continuity
Connector Terminal
E205 2Ground No
AWMIA1099ZZ
Revision: April 20092010 QX56