Page 121 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -121V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF532
PRESENT
OR
STOREDALTERNATOR CHARGE SIGNAL
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Above maximum threshold
2.DEF : Below minimum threshold
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine
running.
Special notes:
If the fault is present, the level 1 warning light comes on.
IMPORTANT
The fault can appear after the alternator has been saturated for too long.
For stored faults, clear the fault, switch off the ignition and wait for 1 minute before
carrying out a road test to confirm the fault before any operation.
Run a multiplex network test (see 88B, Multiplexing).
If the fault is still present, check the insulation and continuity on the following connection:
Injection computer, connector C, track A3Alternator, Track 2, black connector
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF532
Page 122 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -122V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF619
PRESENT
OR
STOREDEGR VALVE JAMMED OPEN
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after a road test.
Priorities when dealing with a number of faults:
–DF118 EGR solenoid valve servo-control,
–DF209 EGR valve position sensor circuit,
–DF272 EGR valve control circuit,
if they are present or stored.
Special note:
If the fault is present:
–The EGR and turbocharging functions are inhibited.
–The level 1 warning light is lit.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF619
Page 123 of 273
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -123V3 MR-372-J84-13B250$450.mif
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF619
CONTINUED
Check the operation of the EGR valve:
–exit fault finding mode in CLIP,
–switch off the vehicle ignition,
–disconnect the EGR valve connector,
–remove the EGR valve.
–Check that there are no particles blocking the movement of the piston.
–Clean the EGR valve, (see Technical Note 3916A Cleaning the EGR valve).
–Refit the EGR valve, run command SC036 Reinitialise programming and select EGR valve to reinitialise the
EGR valve offsets (see Replacement of components).
If the valve is jammed or irrevocably seized, replace the EGR valve. Run command SC036 Reinitialise
programming and select EGR valve to reinitialise the EGR valve offsets (see Replacement of components).
Page 124 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -124V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF620
PRESENT
OR
STOREDEGR VALVE FOULED
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after a road test.
Priorities when dealing with a number of faults:
–DF118 EGR solenoid valve servo-control,
–DF209 EGR valve position sensor circuit,
–DF272 EGR valve control circuit,
if they are present or stored.
Special note:
If the fault is present:
–the EGR function is inhibited,
–turbocharging is inhibited,
–the level 1 warning light is lit.
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF620
Page 125 of 273
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -125V3 MR-372-J84-13B250$450.mif
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF620
CONTINUED
Check the operation of the EGR valve:
–exit fault finding mode in CLIP,
–switch off the vehicle ignition,
–disconnect the EGR valve connector,
–remove the EGR valve.
–Check that there are no particles blocking the movement of the piston.
–Clean the EGR valve, (see Technical Note 3916A Cleaning the EGR valve).
–Refit the EGR valve, run command SC036 Reinitialise programming and select EGR valve to reinitialise the
EGR valve offsets (see Replacement of components).
If the valve is jammed or irrevocably seized, replace the EGR valve. Run command SC036 Reinitialise
programming and select EGR valve to reinitialise the EGR valve offsets (see Replacement of components).
Page 126 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -126V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF621
PRESENT
OR
STOREDEGR VALVE JAMMED OPEN (OBD FAULT)
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after a road test.
Priorities when dealing with a number of faults:
–DF118 EGR solenoid valve servo-control,
–DF209 EGR valve position sensor circuit,
–DF272 EGR valve control circuit,
if they are present or stored.
Special note:
If the fault is present:
–there is heavy smoke coming from the exhaust,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF621
Page 127 of 273
DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -127V3 MR-372-J84-13B250$450.mif
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF621
CONTINUED
Check the operation of the EGR valve:
–exit fault finding mode in CLIP,
–switch off the vehicle ignition,
–disconnect the EGR valve connector,
–remove the EGR valve.
–Check that there are no particles blocking the movement of the piston.
–Clean the EGR valve, (see Technical Note 3916A Cleaning the EGR valve).
–Refit the EGR valve, run command SC036 Reinitialise programming and select EGR valve to reinitialise the
EGR valve offsets (see Replacement of components).
If the valve is jammed or irrevocably seized, replace the EGR valve. Run command SC036 Reinitialise
programming and select EGR valve to reinitialise the EGR valve offsets (see Replacement of components).
Page 128 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -128V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF652
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Short circuit or open circuit to + 12 V
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present:
–ignition is on (CC.0),
–following a road test, engine warm (CO.1).
Special notes:
If the fault is present:
–the EGR function is inhibited,
–particle filter regeneration is inhibited,
–the vehicle performance is reduced,
–the level 1 warning light is illuminated.
Priorities when dealing with a number of faults:
DF011 Sensor voltage supply no. 1
IMPORTANT
The turbine upstream temperature sensor only measures temperatures above
200˚C.
Check the condition of the turbine upstream temperature sensor connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II, component code 1589).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II, component code 120).
If one of the connectors is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF652