INDEX - In order of parts nameC-20
Wiring diagram
page Circuit diagram page Connector
No. Parts name
SSRS-ECUC-41B-249,251B-19,25
StarterB-18B-79B-11,15
StarterB-19B-79B-11,15
Steering wheel sensorC-230B-202,210,218,226,236,246B-23,29
Stop lamp switchC-103B-144,145,198,206,212,220,228,238B-20,26
TThrottle position sensorB-02B-89,97,215,223,231,241B-10,14
Trunk lid latch switchF-10B-119,123B-38,39
VVehicle speed sensorB-03B-92,100,150,154,197B-10,14
WWaste gate solenoid valveB-36B-91,99B-11,15
Wheel speed sensor (Front:LH)A-03B-203,211,217,225,233,243B-6,8
Wheel speed sensor (Front:RH)A-37B-203,211,217,225,233,243B-7,9
Wheel speed sensor (Rear:LH)
D-10B-203,211,217,225,233,243B-30,32
Wheel speed sensor (Rear:RH)
D-04B-203,211,217,225,233,243B-30,32
Windshield washer motorF-21B-186,190B-38,39
Windshield wiper motorB-01B-186,190B-10,14
GENERAL -How to Use Troubleshooting/Inspection Service Points00-10
HOW TO USE THE INSPECTION PROCEDURES
The causes of a high frequency of problems occurring in electronic circuitry are generally the connectors,
components, the ECU and the harnesses between connectors, in that order. These inspection procedures
follow this order, and they first try to discover a problem with a connector or a defective component.
DIndicator does not turn on or off even if control
mode switch is pressed.
DIndicator switch should not be illuminated is
illuminated.Probable cause
OK
OK
OK
Measure at switch connector A-44
DDisconnect the connector, and measure at the harness
side.
DVoltage between terminal 6 - earth and terminal 8 -
earth
OK:Approx. 5V
OK
NG
Check the following connector.A-44
Repair
OK
Check trouble symptom.
Replace the ECS-ECU.
In the above cases, the ECS switch circuit is defective or the indicator
circuit is defective.
CHECKING PROCEDURE 4
2. Indicates inspection carried out using the
MUT-II.
Indicates the operation and inspection proce-
dures.
Indicates the OK judgement conditions.
3. Detailed inspection procedures (methods)
such as component inspection and circuit
inspection are listed on a separate page, and
are given here for reference.
5. Inspect the contact condition at each connector terminal.
(Refer to Connector Inspection Service Points.)
The connector position can be located in the wiring diagram in the
electrical wiring manual by means of this symbol.
Caution
After carrying out connector inspection, always be sure to
reconnect the connector as it was before.
6. Confirm that there are trouble symptoms. If trouble symptoms have
disappeared, the connector may have been inserted incorrectly and the
trouble symptom may have disappeared during inspection.
If it seems that trouble symptoms still remain, proceed to the next page of
instructions.
7. If trouble symptoms still remain up to this stage, there is a possibility that there is an
open or short circuit in the harness between the connectors, so check the harness.
Alternatively, the cause may be a defective ECU, so try replacing the ECU and check
if the trouble symptom disappears.
NGECU switch component inspection (Refer to P.33-44.)
NG
1. Comments on the diagnosis code or trouble
symptom above.
MUT-IIData list
17 Control mode selection switch
OK:Voltage changes between approx. 0V→approx.
2.5V→approx. 5V when the switch is operated.
4. Indicates voltage and resistance to be measured at a particular
connector.
(Refer to Connector Measurement Service Points.)
The connector position can be located in the wiring diagram in the
electrical wiring manual by means of this symbol.
Indicates operation and inspection procedures, inspection terminals
and inspection conditions.
Indicates the OK judgement conditions.
HARNESS INSPECTION
Check for an open or short circuit in the harness between the terminals which were defective according
to the connector measurements. Carry out this inspection while referring to the electrical wiring manual.
Here, “Check harness between power supply and terminal xx” also includes checking for blown fuses.
For inspection service points when there is a blown fuse, refer to “Inspection Service Points for a Blown
Fuse.”
MEASURES TO TAKE AFTER REPLACING THE ECU
If the trouble symptoms have not disappeared even after replacing the ECU, repeat the inspection procedure
from the beginning.
SRS -Troubleshooting52B-30
Code No.41 Power supply circuit system (fuse No.2
circuit)Possible Cause
This codes output when the voltage between terminal IG1(SRS-ECU, terminal
No.16) and earth has been below the standard value for 5 seconds.
However, code No.41 is automatically erased and SRS warning lamp goes out
when a normal operation is resumed. If code No.41 and 42 are output at the
same time, check the battery first since the battery voltage may have decreased.DHarness or connector fault
DSRS-ECU inoperable
block and the combination meter>
Measure at the junction block connector
C-213.
DDisconnect the junction block connector
C-213 and measure at the harness
side.
DContinuity check between terminal 25
and body earth
Caution
Do not directly insert a probe or
other devices at the front of the
connector to avoid a possible
decrease in the contact pressure.
OK:No continuity
block>
Measure at the junction block connector C-213.
DDisconnect the junction block connector C-213 and
measure at the harness side.
DContinuity check between terminal 24 and body earth
Caution
Do not directly insert a probe or other devices at the
front of the connector to avoid a possible decrease in
the contact pressure.
OK:No continuity
NGCorrect the harness between the junction block and
combination meter (SRS warning lamp).
NGOK
NGNG
Check the trouble symptoms.Correct
Check the harness between the SRS-ECU and the ignition
switch IG
1, and repair if necessary. Fuse is normal
NG
Fuse disconnection
Check the junction block general fuse No.2.
Fuse disconnection
Check when fuse disconnects
DReplace the fuse.
DTurn the ignition switch to the ON position and then turn it
to the OFF position after one minute or more has passed.
Check the fuse.
OK
OK
Replace the SRS-ECU.
>Measure at the SRS-ECU connector C - 21.
DDisconnect the SRS-ECU connector C-21.
DConnect the negative ( - ) terminal of the battery
DIgnition switch: ON
DMeasure at the harness side
DVoltage between terminal 16 and body earth
Caution
Do not directly insert a probe or other devices at the
front of the connector to avoid a possible decrease in
the contact pressure.
OK:9 V or more
Check the other circuits using the general fuse No.2.
(See the Electrical Wiring Diagram.) OK
Check connector:C-21, C-213, C-210
Go to Next PageConnector C-21
Connector C-213
Connector C-213
SRS -Troubleshooting52B-32
Code No.42 Power supply circuit system (fuse No.3
circuit)Possible Cause
This code is output when the voltage between terminal IG1(SRS-ECU, terminal
No.13) and earth has been below the standard value for 5 seconds.
However, code No.42 is automatically erased and SRS warning lamp goes out
when a normal operation is resumed.If code No.41 and 42 are output at the
same time, check the battery first since the battery voltage may have decreased.DHarness or connector fault
DSRS-ECU inoperable
OK
Check the other circuits using the general
fuse No.3. (See the Electrical Wiring
Diagram.)
NGOK
NG
NG
NG
Check connector:C-21, C-213, C-210
Check the trouble
symptoms.Correct
Check the harness between the SRS-ECU and the ignition
switch IG
1, and repair if necessary.
NG
Fuse disconnection
Fuse disconnection
OK
Replace the SRS-ECU.
switch IG
1
>Measure at the SRS-ECU connector C - 21.
DDisconnect the SRS-ECU connector C-21 and measure at
the harness side.
DConnect the negative ( - ) terminal of the battery
DIgnition switch: ON
DVoltage between terminal 13 and body earth
Caution
Do not directly insert a probe or other devices at the
front of the connector to avoid a possible decrease in
the contact pressure.
OK:9 V or more
OK
Check the harness between the SRS-ECU and junction block,
and repair if necessary.
block>
Measure at the C-21 SRS-ECU connector.
DDisconnect the SRS-ECU connector C-21 and measure at
the harness side.
DContinuity check between terminal 13 and body earth
Caution
Do not directly insert a probe or other devices at the
front of the connector to avoid a possible decrease in
the contact pressure.
OK:No continuity
Replace the SRS-ECU.Fuse is normal
Check the junction block general fuse No.3.
Check when fuse disconnects
DReplace the fuse.
DTurn the ignition switch to the ON position and then turn it
to the OFF position after one minute or more has passed.
Check the fuse.
block>
Measure at the junction block connector C-213.
DDisconnect the junction block connector C-213 and
measure at the harness side.
DContinuity check between terminal 7 and body earth
Caution
Do not directly insert a probe or other devices at the
front of the connector to avoid a possible decrease in
the contact pressure.
OK:No continuityConnector C-21
Connector C-213
Connector C-21